Chint NL1-100-2100/100-S time delayed residual current device, a 100 A 100 mA 2 pole S type RCCB for selective earth leakage protection in consumer units, distribution boards and industrial electrical installations.
£38.73
The Chint NL1-100-2100/100-S is a reliable time delayed residual current device (RCD) designed to provide selective earth leakage protection in residential, commercial and light industrial electrical installations. As part of the Chint NL1 RCCB series, it automatically disconnects the circuit when residual current faults are detected, helping protect people, equipment and property from electrical hazards.
This device is a 2 pole, S type time delayed RCD designed to provide discrimination with downstream residual current devices. The time delayed tripping characteristic helps reduce nuisance tripping and supports coordinated residual current protection in distribution boards, sub-main circuits and larger electrical installations.
With a rated current of 100 A and a residual operating current of 100 mA, the NL1-100-2100/100-S provides dependable earth leakage protection for higher capacity single-phase circuits. Its DIN rail mounting format enables quick, neat and secure installation in modern electrical enclosures.
Time delayed residual current devices such as the Chint NL1-100-2100/100-S continuously monitor the difference between live and neutral current. When an earth leakage fault occurs, the device disconnects the circuit after a controlled delay, helping provide selectivity with downstream RCDs.
The NL1 series provides residual current protection only and should be installed alongside suitable over-current protection, such as an MCB or fuse. Its S type characteristic makes it particularly useful for upstream protection where discrimination and reduced nuisance tripping are important.
Tick the specs you need, then view products that match.
| Current | 100 A | |
|---|---|---|
| Poles | 2-pole | |
| Device Type | RCD | |
| Residual Current | 100 mA | |
| Manufacturer | Chint | |
| Series | NL1-100 | |
| Model | NL1-100-2100/100-S | |
| Product type | Time delayed residual current device / RCCB | |
| Number of poles | 2 pole | |
| Rated current | 100 A | |
| Residual operating current | 100 mA | |
| Tripping type | S type time delayed | |
| Rated voltage | 230 / 240 V AC | |
| Rated frequency | 50 / 60 Hz | |
| Rated conditional short-circuit current | 6 kA | |
| Rated conditional residual short-circuit current | 6 kA | |
| Rated insulation voltage | 500 V | |
| Rated impulse withstand voltage | 4 kV | |
| Mounting type | 35 mm DIN rail | |
| Connection type | Cable or busbar connection | |
| Protection rating | IP20 | |
| Operating temperature | approx. -25 to +70°C | |
| Standards | IEC / EN 61008-1 |
The Chint NL1-100-2100/100-S provides time delayed residual current protection by disconnecting the circuit when earth leakage faults are detected.
The Chint NL1-100-2100/100-S has a rated current of 100 A.
This RCD has a residual operating current of 100 mA.
S type time delayed operation provides a controlled delay before tripping, helping achieve discrimination with downstream RCDs and reducing unwanted nuisance tripping.
No. The NL1-100-2100/100-S provides residual current protection only and should be installed with suitable over-current protection.
Chint time delayed residual current devices are widely used by electrical contractors, panel builders and maintenance engineers to deliver dependable selective earth leakage protection across residential, commercial and industrial electrical installations.