Why Choose the IMO B6CRC1N10-30-A Compact RCBO?

The IMO B6CRC1N10-30-A is a compact Residual Current Circuit Breaker with Overcurrent Protection (RCBO) engineered to protect electrical circuits against earth leakage, overload and short-circuit faults. By combining the functions of an MCB and RCD into a single compact unit, it simplifies installation whilst maximising available space inside consumer units, distribution boards and electrical control panels.

As part of the IMO B6 Compact RCBO range, this model incorporates Type A residual current protection, enabling detection of both sinusoidal AC and pulsating DC residual currents. This makes it particularly suitable for modern electrical installations supplying LED lighting, electronic appliances, switched-mode power supplies and other equipment containing semiconductor components.

With a 10 A rated current, 30 mA residual operating current, Type C tripping characteristic and a 6 kA breaking capacity, the B6CRC1N10-30-A delivers dependable protection for lighting, control circuits, automation equipment and other low-current installations requiring reliable fault protection.

Key Advantages

  • Combined earth leakage, overload and short-circuit protection.
  • 10 A rated current ideal for lighting and low-power electrical circuits.
  • 30 mA Type A residual current protection for enhanced personnel safety.
  • Detects AC and pulsating DC leakage currents.
  • Type C tripping characteristic suitable for moderate inrush current applications.
  • Compact single-module design maximises DIN rail space.

Key Features

  • IMO B6 Compact RCBO series.
  • 10 A rated current.
  • 30 mA residual operating current.
  • Type A residual current protection.
  • Type C tripping characteristic.
  • 6 kA short-circuit breaking capacity.
  • Single Pole + Neutral configuration.
  • Compact single-module (18 mm) design.
  • 230/240 V AC operation.
  • 35 mm TS35 DIN rail mounting.
  • Finger-safe screw terminals.
  • Integrated test button.

Compact Protection for Modern Electrical Installations

The IMO B6CRC1N10-30-A continuously monitors electrical circuits for overloads, short circuits and residual current faults. Should an abnormal condition occur, the RCBO disconnects the supply rapidly, helping to protect people, equipment and property whilst reducing the risk of electrical fires and costly downtime.

Its Type A residual current sensing is ideal for today's electrical installations where electronic equipment can generate pulsating DC leakage currents. Combined with a Type C tripping curve, it provides dependable protection for circuits supplying lighting, control equipment, transformers and automation devices with moderate starting currents.

Typical Applications

  • Lighting circuits.
  • LED lighting installations.
  • Control panels.
  • Automation systems.
  • Residential consumer units.
  • Commercial distribution boards.
  • OEM machinery.
  • General low-current electrical circuits.

Technical Specifications

Tick the specs you need, then view products that match.

Phase Single Phase
Voltage 230 V
Poles 1-pole + N
Device Type RCBO
Trip Curve C curve
Breaking Capacity 6 kA
Residual Current 30 mA
RCD Type Type A
Manufacturer IMO Precision Controls
Series B6 Compact RCBO
Model B6CRC1N10-30-A
Product type Residual Current Circuit Breaker with Overcurrent Protection (RCBO)
Rated current 10 A
Residual operating current 30 mA
Residual current type Type A
Tripping characteristic Type C
Breaking capacity 6 kA
Pole configuration 1 Pole + Neutral
Rated operational voltage 230/240 V AC
Frequency 50 Hz
Standard IEC/EN 61009-1
Protection rating IP20
Mounting type 35 mm TS35 DIN rail
Terminal capacity 1–25 mm²
Dimensions (H × W × D) Approx. 81 × 18 × 77.6 mm
HS Code 8536201090
Country of Manufacture China

Frequently Asked Questions

What is the IMO B6CRC1N10-30-A used for?

It provides combined protection against earth leakage, overload and short-circuit faults for low-current electrical circuits in residential, commercial and industrial installations.

What type of residual current protection does it provide?

This RCBO provides Type A residual current protection, detecting both AC and pulsating DC residual currents.

What is the rated current?

The IMO B6CRC1N10-30-A has a rated current of 10 A.

Is this a compact RCBO?

Yes. It features a compact single-module 18 mm design that maximises available DIN rail space within distribution boards and consumer units.

How is the device installed?

The RCBO is designed for installation on a standard 35 mm TS35 DIN rail using secure screw terminal connections.

Trusted by Electrical Professionals