B6CR1N40-100-A IMO RCBO 10kA, 100mA, C Curve 1 Pole + N, 40 Amp, 230VAC

B6CR1N40-100-A IMO RCBO 10kA, 100mA, C Curve 1 Pole + N, 40 Amp, 230VAC

SKU: B6CR1N40-100-AAlt SKU: B6CR1N40100AMPN: B6CR1N40-100-A
Price
List Price £102.04 ex VAT
Your Price (ex VAT) Save 30%
£71.43 30% OFF
You save £30.61 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £71.43
Trade pricing is personalised to your account

Manufacturer Lead Time

£71.43

Why Choose the IMO B6CR1N40-100-A RCBO?

The IMO B6CR1N40-100-A is a high-performance Residual Current Circuit Breaker with Overcurrent Protection (RCBO) designed to protect electrical installations against earth leakage, overload and short-circuit faults. Combining the functions of an MCB and RCD into a single compact device, it simplifies installation whilst delivering reliable protection for residential, commercial and industrial electrical systems. Manufactured in accordance with IEC 61009, it offers dependable performance in demanding environments.

Part of the trusted IMO B6 RCBO range, this model incorporates Type A residual current protection, enabling detection of both AC and pulsating DC residual currents commonly produced by modern electronic equipment. Its compact 1 Pole + Neutral design, finger-safe terminals and DIN rail mounting make it ideal for distribution boards, control panels and OEM equipment.

Featuring a 40 A rated current, 100 mA residual operating current, a Type C tripping characteristic and a 10 kA short-circuit breaking capacity, the B6CR1N40-100-A provides reliable circuit protection for higher-load installations including machinery, commercial power distribution and industrial equipment.

Key Advantages

  • Combined earth leakage, overload and short-circuit protection.
  • 40 A rated current for higher power applications.
  • 100 mA Type A residual current protection for dependable fault detection.
  • Type C tripping characteristic suitable for moderate inrush currents.
  • 10 kA breaking capacity for enhanced fault protection.
  • Compact DIN rail mounted design saves valuable enclosure space.

Key Features

  • IMO B6 RCBO series.
  • 40 A rated current.
  • 100 mA residual operating current.
  • Type A residual current protection.
  • Type C tripping characteristic.
  • 10 kA short-circuit breaking capacity.
  • 1 Pole + Neutral configuration.
  • 230 V AC operation.
  • 35 mm DIN rail mounting.
  • Finger-safe connection terminals.
  • Contact position indication window.

Reliable Protection for Higher Load Circuits

The IMO B6CR1N40-100-A continuously monitors electrical circuits for overloads, short circuits and earth leakage faults. If an abnormal condition occurs, the RCBO disconnects the supply rapidly, helping protect personnel, equipment and electrical installations whilst reducing the risk of electrical fires and unplanned downtime.

Its Type A residual current detection makes it particularly suitable for modern electrical installations incorporating electronic devices, variable speed equipment, LED lighting and switched-mode power supplies that may generate pulsating DC leakage currents.

Typical Applications

  • Industrial control panels.
  • Commercial distribution boards.
  • Manufacturing facilities.
  • OEM machinery.
  • Building services installations.
  • Motor and pump circuits.
  • Commercial electrical systems.
  • General power distribution.

Technical Specifications

Tick the specs you need, then view products that match.

Voltage 230 V
Phase Single Phase
Poles 1-pole + N
Device Type RCBO
Trip Curve C curve
Breaking Capacity 10 kA
Residual Current 100 mA
RCD Type Type A
Manufacturer IMO Precision Controls
Series B6 RCBO
Model B6CR1N40-100-A
Product type Residual Current Circuit Breaker with Overcurrent Protection (RCBO)
Rated current 40 A
Residual operating current 100 mA
Residual current type Type A
Tripping characteristic Type C
Breaking capacity 10 kA
Pole configuration 1 Pole + Neutral
Rated operational voltage 230 V AC
Frequency 50 / 60 Hz
Standard IEC 61009
Protection rating IP20
Mounting type 35 mm DIN rail
Terminal capacity Up to 35 mm² solid conductor
HS Code 8536201090
Country of Manufacture China

Frequently Asked Questions

What is the IMO B6CR1N40-100-A used for?

It provides combined protection against earth leakage, overload and short-circuit faults for individual electrical circuits in commercial and industrial installations.

What does the 100 mA residual current rating mean?

The RCBO disconnects the circuit when earth leakage reaches approximately 100 mA, helping protect electrical installations against earth fault conditions.

What type of residual current protection does it provide?

The device provides Type A protection, detecting both AC and pulsating DC residual currents.

What does the Type C tripping characteristic indicate?

Type C RCBOs are designed for circuits supplying equipment with moderate inrush currents, including motors, transformers and industrial machinery.

How is the device installed?

The B6CR1N40-100-A is designed for installation on a standard 35 mm DIN rail within distribution boards, consumer units and industrial control panels.