B6BRC1N06-30 IMO RCBO 6kA, 30mA, B Curve 1 P + N, 6Amp, 230VAC

B6BRC1N06-30 IMO RCBO 6kA, 30mA, B Curve 1 P + N, 6Amp, 230VAC

SKU: B6BRC1N06-30Alt SKU: B6BRC1N0630MPN: B6BRC1N06-30
Price
List Price £75.32 ex VAT
Your Price (ex VAT) Save 30%
£52.72 30% OFF
You save £22.60 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £52.72
Trade pricing is personalised to your account

Manufacturer Lead Time

£52.72

Why Choose the IMO B6BRC1N06-30 RCBO?

The IMO B6BRC1N06-30 is a compact Residual Current Circuit Breaker with Overcurrent Protection (RCBO) designed to protect single-phase electrical circuits against earth leakage, overload and short-circuit faults. By combining residual-current and overcurrent protection within one device, it helps simplify distribution-board layouts, reduce wiring requirements and conserve valuable DIN rail space.

Featuring a 6 A rated current, 30 mA residual operating current, Type AC residual-current protection and a C curve tripping characteristic, the B6BRC1N06-30 is suited to control, lighting and auxiliary circuits containing equipment with moderate starting currents.

The device incorporates a 1 Pole + Neutral configuration, allowing both the live and neutral conductors to be disconnected when operated. Its 6 kA short-circuit breaking capacity, compact DIN rail construction and integrated test button make it a practical protective device for commercial, industrial and OEM electrical installations.

Key Advantages

  • Combined earth leakage, overload and short-circuit protection.
  • 6 A rated current for low-current control and auxiliary circuits.
  • 30 mA residual sensitivity provides additional protection against electric shock.
  • Type AC protection detects alternating sinusoidal residual currents.
  • C curve tripping characteristic accommodates moderate equipment starting currents.
  • Compact integrated design helps reduce wiring and conserve enclosure space.

Key Features

  • IMO B6 RCBO range.
  • 6 A rated current.
  • 30 mA rated residual operating current.
  • Type AC residual-current characteristics.
  • C curve overcurrent protection.
  • 1 Pole + Neutral (1P+N) configuration.
  • 6 kA short-circuit breaking capacity.
  • Thermal-magnetic overcurrent protection.
  • DIN rail mounted construction.
  • Integrated residual-current test button.

Combined Residual-Current and Overcurrent Protection

The IMO B6BRC1N06-30 monitors the protected circuit for residual-current imbalance, sustained overloads and short-circuit conditions. When a potentially hazardous fault is detected, the RCBO disconnects the circuit to help protect personnel, electrical wiring and connected equipment.

Its C curve operating characteristic makes it suitable for circuits containing equipment that may draw moderate inrush currents during start-up. Combining multiple protective functions within one device can also simplify installation, improve circuit-level fault identification and reduce the number of components required within the enclosure.

Typical Applications

  • Industrial control circuits.
  • Commercial lighting installations.
  • Contactors and control relays.
  • Small motors and inductive loads.
  • Building management systems.
  • OEM machinery and automation equipment.

Technical Specifications

Tick the specs you need, then view products that match.

Phase Single Phase
Voltage 230 V
Poles 1-pole + N
Device Type RCBO
Trip Curve C curve
Breaking Capacity 6 kA
Residual Current 30 mA
Manufacturer IMO Precision Controls
Series B6
Model B6BRC1N06-30
Product type Residual Current Circuit Breaker with Overcurrent Protection
Rated current 6 A
Rated residual operating current 30 mA
Residual-current characteristics Type AC
Tripping characteristic C Curve
Pole configuration 1 Pole + Neutral
Rated operational voltage 230/240 V AC
Rated frequency 50/60 Hz
Short-circuit breaking capacity 6 kA
Protection functions Earth leakage, overload and short circuit
Operating mechanism Thermal-magnetic with residual-current protection
Mounting type 35 mm DIN rail
Test function Integrated test button
HS Code 8536201090
Country of Manufacture China

Frequently Asked Questions

What is the IMO B6BRC1N06-30 used for?

It provides combined earth leakage, overload and short-circuit protection for 6 A single-phase electrical circuits.

What is the rated current of this RCBO?

The IMO B6BRC1N06-30 has a rated current of 6 A.

What residual-current protection does it provide?

It provides 30 mA Type AC residual-current protection for alternating sinusoidal leakage currents.

What does the C curve characteristic mean?

A C curve RCBO accommodates higher starting currents than a B curve device, making it suitable for circuits containing moderate inductive loads, control equipment and small motors.

How is the B6BRC1N06-30 installed?

The device mounts onto a standard 35 mm DIN rail inside a compatible electrical distribution board or control panel.

Trusted Circuit Protection for Professional Installations

IMO RCBOs provide electricians, panel builders and equipment manufacturers with compact protection against residual-current, overload and short-circuit faults across commercial, industrial and automation installations.