B10R4063-500 IMO RCD 10KA, 500mA 3 Pole + N, 63 Amp, 415VAC

B10R4063-500 IMO RCD 10KA, 500mA 3 Pole + N, 63 Amp, 415VAC

SKU: B10R4063-500Alt SKU: B10R4063500MPN: B10R4063-500
Price
List Price £69.36 ex VAT
Your Price (ex VAT) Save 30%
£48.55 30% OFF
You save £20.81 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £48.55
Trade pricing is personalised to your account

Manufacturer Lead Time

Sold in packs of 30

£48.55

Why Choose the IMO B10R4063-500 RCCB?

The IMO B10R4063-500 is a robust and reliable Residual Current Circuit Breaker (RCCB) designed to protect three-phase electrical installations against earth leakage and residual current faults. As part of the dependable IMO B10R circuit protection range, it is suitable for commercial and industrial distribution systems where reliable electrical isolation and leakage-current protection are required.

This RCCB continuously monitors the current flowing through the live and neutral conductors. When an imbalance exceeds the specified threshold, the device rapidly disconnects the circuit, helping reduce the risk of electrical fires, equipment damage and hazards caused by insulation failure.

With a 63 A rated current, 500 mA residual operating current and a 3 Pole + Neutral configuration, the IMO B10R4063-500 is suitable for three-phase circuits, machinery supplies and distribution boards. Its compact modular construction enables straightforward mounting on a standard DIN rail inside electrical panels and enclosures.

Key Advantages

  • Reliable earth leakage and residual current protection.
  • 63 A rated current for commercial and industrial circuits.
  • 500 mA residual operating current for equipment and fire-risk protection.
  • 3 Pole + Neutral configuration for three-phase installations.
  • 10 kA conditional short-circuit rating.
  • Compact modular design for convenient DIN rail installation.

Key Features

  • IMO B10R residual current circuit breaker series.
  • 63 A rated current.
  • 500 mA rated residual operating current.
  • 230/400 V AC rated voltage.
  • 3 Pole + Neutral (4 Pole) configuration.
  • 50/60 Hz rated frequency.
  • 10 kA rated conditional short-circuit current.
  • IP20 protection and standard DIN rail mounting.

Reliable Protection for Three-Phase Electrical Systems

Residual current circuit breakers monitor the electrical current passing through a circuit and identify imbalances caused by leakage to earth. When the leakage reaches the RCCB operating threshold, the device disconnects the supply to help limit damage to wiring, machinery and connected electrical equipment.

The 500 mA sensitivity of the IMO B10R4063-500 makes it particularly suitable for equipment protection, upstream distribution and applications where protection against leakage-related fire risks is required. Appropriate supplementary overcurrent protection should be selected separately because an RCCB does not replace a circuit breaker or fuse.

Typical Applications

  • Industrial electrical distribution boards.
  • Commercial three-phase installations.
  • Machinery and production equipment supplies.
  • Control panels and automation systems.
  • Building services and infrastructure.
  • OEM electrical equipment and panel building.

Technical Specifications

Tick the specs you need, then view products that match.

Voltage 415 V
Phase Three Phase
Poles 3-pole + N
Device Type RCD
Residual Current 500 mA
Manufacturer IMO Precision Controls
Series B10R
Model B10R4063-500
Product type Residual Current Circuit Breaker (RCCB)
Rated current 63 A
Rated residual operating current 500 mA
Rated voltage 230/400 V AC
Rated frequency 50/60 Hz
Pole configuration 3 Pole + Neutral (4 Pole)
Rated conditional short-circuit current 10 kA
Protection rating IP20
Mounting type DIN rail, EN 60715
Terminal capacity up to 35 mm² solid or 25 mm² stranded conductor
Fastening torque 2.0 Nm
Operating temperature -25°C to +55°C
Electrical lifetime more than 4,000 cycles
Dimensions (H × W × D) approx. 81 × 70.5 × 49.7 mm
HS Code 8536201090
Country of Manufacture China

Frequently Asked Questions

What is the IMO B10R4063-500 used for?

It is used to detect earth leakage and residual current faults in three-phase electrical systems, helping protect wiring, machinery and connected equipment.

What is the rated current of this RCCB?

The IMO B10R4063-500 has a rated current of 63 A.

What is the residual operating current?

The device has a rated residual operating current of 500 mA, making it suitable for equipment, distribution and leakage-related fire protection applications.

How many poles does the B10R4063-500 have?

It has a 3 Pole + Neutral configuration, commonly described as a four-pole RCCB for three-phase electrical systems.

Does this RCCB provide overcurrent protection?

No. An RCCB detects residual current leakage but does not provide overload or short-circuit protection, so a suitable circuit breaker or fuse must be installed separately.

Trusted Circuit Protection for Professional Installations

IMO residual current circuit breakers provide dependable earth leakage protection for electrical contractors, panel builders, machine manufacturers and industrial engineers working with modern three-phase distribution systems.