B10R4025-300-A IMO RCD 10KA, 300mA 3 Pole + N, 25 Amp, 415VAC

B10R4025-300-A IMO RCD 10KA, 300mA 3 Pole + N, 25 Amp, 415VAC

SKU: B10R4025-300-AAlt SKU: B10R4025300AMPN: B10R4025-300-A
Price
List Price £96.85 ex VAT
Your Price (ex VAT) Save 30%
£67.80 30% OFF
You save £29.06 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £67.80
Trade pricing is personalised to your account

Manufacturer Lead Time

Sold in packs of 30

£67.80

Why Choose the IMO B10R4025-300-A Type A Residual Current Circuit Breaker?

The IMO B10R4025-300-A is a high-performance Type A Residual Current Circuit Breaker (RCCB) designed to provide dependable protection against earth leakage faults in commercial and industrial electrical installations. Manufactured by IMO Precision Controls, this four-pole RCCB disconnects the electrical supply when hazardous residual currents are detected, helping protect electrical equipment and minimise the risk of fire caused by earth faults.

Unlike a standard Type AC RCCB, the Type A version detects both sinusoidal AC residual currents and pulsating DC residual currents, making it suitable for installations containing modern electronic equipment, variable speed drives, switch-mode power supplies and rectifier circuits. Its compact DIN rail design enables quick installation within electrical distribution boards and control panels.

With a 25A rated current, 300mA residual operating current, 415V AC three-phase plus neutral supply and a 10kA conditional short-circuit rating, the IMO B10R4025-300-A is ideal for industrial distribution systems requiring coordinated earth fault protection.

Key Advantages

  • High-quality 4-pole Type A RCCB for commercial and industrial installations.
  • 25A rated current for three-phase electrical circuits.
  • 300mA residual current sensitivity for earth fault and fire protection.
  • Type A detection for AC and pulsating DC residual currents.
  • 10kA conditional short-circuit rating.
  • Compact DIN rail mounting for straightforward installation.

Key Features

  • IMO B10R Residual Current Circuit Breaker series.
  • 25A rated current.
  • 300mA rated residual operating current (IΔn).
  • 415V AC operating voltage.
  • 3 Pole + Neutral (4 Pole) configuration.
  • Type A residual current protection.
  • 10kA conditional short-circuit rating.
  • DIN rail mounting.
  • Manufactured in accordance with IEC 61008-1.
  • IP20 protection rating.

Reliable Type A Earth Leakage Protection

Type A RCCBs continuously monitor current flowing through live conductors and disconnect the electrical supply when residual current exceeds the rated operating level. Unlike Type AC devices, Type A RCCBs detect both alternating residual currents and pulsating DC leakage currents generated by modern electronic equipment, providing greater application flexibility.

The 300mA operating sensitivity is commonly used to provide protection against earth faults and reduce fire risk in commercial and industrial electrical installations while maintaining dependable operation of larger electrical distribution systems.

Typical Applications

  • Industrial distribution boards.
  • Commercial electrical installations.
  • Machine control panels.
  • Variable speed drive applications.
  • Building services infrastructure.
  • Three-phase power distribution systems with electronic equipment.

Technical Specifications

Tick the specs you need, then view products that match.

Voltage 415 V
Phase Three Phase
Poles 3-pole + N
Device Type RCD
Residual Current 300 mA
Manufacturer IMO Precision Controls
Series B10R RCCB
Model B10R4025-300-A
Product type Type A Residual Current Circuit Breaker (RCCB)
Rated current 25A
Rated residual operating current 300mA
Residual current characteristic Type A
Rated voltage 415V AC
Frequency 50 / 60Hz
Pole configuration 3 Pole + Neutral (4 Pole)
Conditional short-circuit rating 10kA
Protection rating IP20
Mounting type DIN rail EN 60715
Operating temperature -25°C to +55°C
Compliance IEC 61008-1
HS Code 8536201090
Country of Manufacture China

Frequently Asked Questions

What is the IMO B10R4025-300-A used for?

It provides earth leakage protection for three-phase electrical systems and disconnects the supply when dangerous residual currents are detected.

What does Type A mean?

Type A RCCBs detect both alternating AC residual currents and pulsating DC residual currents, making them suitable for installations containing modern electronic equipment.

What is the rated current of this RCCB?

The IMO B10R4025-300-A has a 25A rated current.

Why does this model use 300mA sensitivity?

A 300mA RCCB is typically selected for earth fault and fire protection in commercial and industrial installations rather than additional personal shock protection.

How is the RCCB installed?

The unit mounts directly onto a standard DIN rail inside electrical distribution boards and industrial control panels.

Trusted Protection for Modern Electrical Installations

IMO Precision Controls Type A residual current circuit breakers are trusted by electrical contractors, panel builders and industrial engineers for reliable earth leakage protection, dependable operation and compliance with recognised international safety standards.