B10R2080-30 IMO RCD 10KA, 30mA 1 Pole + N, 80 Amp, 230VAC

B10R2080-30 IMO RCD 10KA, 30mA 1 Pole + N, 80 Amp, 230VAC

SKU: B10R2080-30Alt SKU: B10R208030MPN: B10R2080-30
Price
List Price £79.40 ex VAT
Your Price (ex VAT) Save 30%
£55.58 30% OFF
You save £23.82 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £55.58
Trade pricing is personalised to your account

Manufacturer Lead Time

£55.58

Why Choose the IMO B10R2080-30 Residual Current Device?

The IMO B10R2080-30 is a reliable Type AC Residual Current Device (RCD/RCCB) designed to provide dependable protection against earth leakage faults in single-phase electrical installations. Manufactured by IMO Precision Controls, it forms part of the trusted B10R RCCB series, making it ideal for commercial distribution boards, industrial control panels, machinery and residential electrical systems.

The device continuously monitors the current flowing through the live and neutral conductors. If an earth leakage fault creates an imbalance exceeding the rated residual operating current, the RCCB disconnects the electrical supply, helping reduce the risk of electric shock, equipment damage and electrical fires caused by insulation faults.

Featuring a 80 A rated current, 30 mA residual operating current, 1 Pole + Neutral configuration, 230/400 V AC operation and a 10 kA conditional short-circuit rating, the B10R2080-30 provides dependable residual current protection while allowing quick installation on standard TS35 DIN rail systems.

Key Advantages

  • Reliable Type AC residual current protection.
  • 80 A rated current for higher-capacity circuits.
  • 30 mA residual operating current for additional personnel protection.
  • Detects alternating sinusoidal residual currents.
  • 10 kA conditional short-circuit rating.
  • Compact DIN rail mounting for fast installation.

Key Features

  • IMO B10R residual current device series.
  • 80 A rated operational current.
  • 30 mA rated residual operating current.
  • Type AC residual current characteristic.
  • 1 Pole + Neutral (2 Pole) configuration.
  • 230/400 V AC rated voltage.
  • 10 kA conditional short-circuit capacity.
  • DIN rail mounting to EN 60715.

Reliable Earth Leakage Protection

Residual current devices continuously compare the current flowing through the live conductor with the current returning through the neutral conductor. Under normal operating conditions these currents remain balanced. If current leaks to earth due to damaged insulation or accidental contact, the RCCB disconnects the supply within milliseconds to improve electrical safety.

The 30 mA sensitivity of the IMO B10R2080-30 provides additional protection against electric shock and is suitable for a wide range of commercial, industrial and residential installations. As an RCCB, it provides residual current protection only and should always be installed alongside a suitably rated miniature circuit breaker or fuse for overload and short-circuit protection.

Typical Applications

  • Commercial electrical distribution boards.
  • Industrial control panels.
  • Residential consumer units.
  • OEM machinery and equipment.
  • General-purpose earth leakage protection.
  • Building services and automation systems.

Technical Specifications

Tick the specs you need, then view products that match.

Voltage 230 V
Phase Single Phase
Poles 1-pole + N
Device Type RCD
Residual Current 30 mA
Manufacturer IMO Precision Controls
Series B10R
Model B10R2080-30
Alternative SKU B10R208030
Product type Residual Current Device (RCD/RCCB)
Rated current 80 A
Rated residual operating current 30 mA
Residual current characteristic Type AC
Pole configuration 1 Pole + Neutral (2 Pole)
Rated voltage 230/400 V AC
Frequency 50 / 60 Hz
Conditional short-circuit rating 10 kA
Terminal capacity 1–25 mm²
Mounting type TS35 DIN Rail
Protection rating IP20
Standard IEC/EN 61008-1
Dimensions (H × W × D) 81 × 35.1 × 78.5 mm
Weight 0.206 kg
Barcode 5059394609936
HS Code 8536201090
Country of Manufacture China

Frequently Asked Questions

What is the IMO B10R2080-30 used for?

The B10R2080-30 protects electrical circuits by disconnecting the supply when earth leakage or residual current faults are detected.

What is the rated current?

The IMO B10R2080-30 has a rated operational current of 80 A.

What residual current sensitivity does it provide?

The device has a 30 mA rated residual operating current, providing additional protection against electric shock and earth leakage faults.

What type of residual current does it detect?

The B10R2080-30 is a Type AC RCCB designed to detect alternating sinusoidal residual currents.

Does this RCCB provide overload protection?

No. The B10R2080-30 provides residual current protection only and should always be installed alongside a suitably rated miniature circuit breaker or fuse for overload and short-circuit protection.

Trusted Electrical Protection from IMO

IMO B10R residual current devices are trusted by electrical contractors, OEM panel builders and industrial engineers for dependable earth leakage protection in commercial, industrial and residential electrical installations.