Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
£347.65
The IMO B10R2063-30-B is a high-performance Type B Residual Current Device (RCD/RCCB) designed to provide comprehensive earth leakage protection in modern single-phase electrical installations. Its advanced residual current detection makes it suitable for circuits containing power electronics, inverters and equipment capable of producing AC, pulsating DC or smooth DC leakage currents.
The device continuously compares the current flowing through the live conductor with the current returning through the neutral conductor. When an earth leakage fault creates an imbalance above the rated operating threshold, the RCCB disconnects the electrical supply, helping reduce the risk of electric shock, equipment damage and electrically initiated fires.
Featuring a 63 A rated current, 30 mA residual operating current, 1 Pole + Neutral configuration and a 10 kA rated conditional short-circuit current, the B10R2063-30-B is particularly suited to EV charging equipment, solar photovoltaic systems, variable-speed drives, UPS installations and other electronically controlled loads.
Conventional Type AC and Type A residual current devices are not designed to detect every form of leakage current that may be generated by modern power-electronic equipment. Smooth DC residual current can saturate the sensing mechanism of an unsuitable RCD, potentially preventing reliable operation during an earth fault.
The Type B characteristic of the IMO B10R2063-30-B provides enhanced detection across a broader range of residual-current waveforms. This includes sinusoidal AC, pulsating DC, composite-frequency and smooth DC leakage currents associated with rectifiers, inverters, frequency converters and electronically controlled equipment.
Its 30 mA residual operating current provides additional protection against electric shock where a Type B device is required by the equipment manufacturer, installation design or applicable wiring regulations. As an RCCB, it does not provide independent overload or short-circuit protection and must be used with an appropriately rated MCB, MCCB or fuse.
Tick the specs you need, then view products that match.
| Voltage | 230 V | |
|---|---|---|
| Phase | Single Phase | |
| Poles | 1-pole + N | |
| Device Type | RCD | |
| Residual Current | 30 mA | |
| RCD Type | Type B | |
| Manufacturer | IMO Precision Controls | |
| Series | B10R | |
| Model | B10R2063-30-B | |
| Alternative SKU | B10R206330B | |
| Product type | Residual Current Circuit Breaker (RCD/RCCB) | |
| Rated current | 63 A | |
| Rated residual operating current | 30 mA | |
| Residual current characteristic | Type B | |
| Detected residual currents | Sinusoidal AC, pulsating DC and smooth DC | |
| Pole configuration | 1 Pole + Neutral (2-pole) | |
| Rated voltage | 230/400 V AC | |
| Rated frequency | 50/60 Hz | |
| Rated conditional short-circuit current | 10 kA | |
| Residual tripping current range | 0.5 IΔn to 1 IΔn | |
| Fastening torque | 2.0 Nm | |
| Terminal capacity | Up to 35 mm² solid or 25 mm² stranded conductor | |
| Mounting type | DIN rail EN 60715 | |
| Protection rating | IP20 | |
| Operating temperature | -25°C to +55°C | |
| Applicable standards | IEC/EN 61008-1 and IEC/EN 62423 | |
| HS Code | 8536201090 | |
| Country of Manufacture | China |
The B10R2063-30-B provides earth leakage protection for circuits containing equipment that may generate AC, pulsating DC or smooth DC residual currents.
Type B means the RCCB can detect sinusoidal AC, pulsating DC and smooth DC residual currents, making it suitable for inverter-based and power-electronic equipment.
The IMO B10R2063-30-B has a rated operational current of 63 A.
Yes. A 30 mA residual operating current is commonly used to provide additional protection against electric shock, subject to the installation design and applicable electrical regulations.
It can be suitable for EV charging installations requiring Type B residual current protection. The charging equipment manufacturer's instructions and applicable wiring regulations must always be followed.
Yes. Type B RCCBs are commonly used where solar inverters or associated equipment may generate smooth DC or mixed-frequency residual currents.
No. The B10R2063-30-B provides residual current protection only and must be installed with a suitably rated circuit breaker or fuse for overload and short-circuit protection.