B10R2040-100-A IMO RCD 10KA, 100mA 1 Pole + N, 40 Amp, 230VAC

B10R2040-100-A IMO RCD 10KA, 100mA 1 Pole + N, 40 Amp, 230VAC

SKU: B10R2040-100-AAlt SKU: B10R2040100AMPN: B10R2040-100-A
Price
List Price £68.68 ex VAT
Your Price (ex VAT) Save 30%
£48.08 30% OFF
You save £20.60 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £48.08
Trade pricing is personalised to your account

Manufacturer Lead Time

Sold in packs of 60

£48.08

Why Choose the IMO B10R2040-100-A Type A Residual Current Device?

The IMO B10R2040-100-A is a high-quality Type A Residual Current Device (RCD/RCCB) designed to provide dependable protection against earth leakage faults in single-phase electrical installations. Manufactured by IMO Precision Controls, it forms part of the proven B10R RCCB series, offering reliable protection for industrial control panels, commercial distribution systems and machinery.

The device continuously monitors the current flowing through the live and neutral conductors. If an earth leakage fault causes an imbalance above the rated residual operating current, the RCD disconnects the supply, helping reduce the risk of electric shock and equipment damage. Its Type A characteristic enables detection of both AC and pulsating DC residual currents, making it suitable for modern electronic loads and industrial equipment.

With a 40 A rated current, 100 mA residual operating current, 1 Pole + Neutral configuration and a 230 V AC operating voltage, the B10R2040-100-A delivers dependable earth leakage protection while offering straightforward DIN rail installation in electrical distribution equipment.

Key Advantages

  • Reliable Type A residual current protection for industrial and commercial installations.
  • 40 A rated current for higher load circuits.
  • 100 mA residual operating current for earth leakage protection.
  • Type A protection detects AC and pulsating DC residual currents.
  • 10 kA conditional short-circuit rating.
  • Compact DIN rail mounting for simple installation.

Key Features

  • IMO B10R residual current device series.
  • 40 A rated operational current.
  • 100 mA rated residual operating current.
  • Type A residual current characteristic.
  • 1 Pole + Neutral configuration.
  • 230 V AC rated voltage.
  • 10 kA conditional short-circuit capacity.
  • DIN rail mounting for electrical panels and distribution boards.

Reliable Earth Leakage Protection

Residual current devices monitor the balance between live and neutral currents. When current leaks to earth because of damaged insulation, faulty equipment or accidental contact, the device disconnects the supply within milliseconds to help improve electrical safety.

The Type A characteristic allows the IMO B10R2040-100-A to detect both sinusoidal AC and pulsating DC residual currents, making it suitable for installations supplying modern electronic equipment, industrial controls and automation systems. The device should always be installed alongside appropriate overcurrent protection.

Typical Applications

  • Industrial electrical distribution boards.
  • Commercial electrical installations.
  • Industrial machinery and automation systems.
  • Control panels and switchboards.
  • OEM electrical equipment.
  • General earth leakage protection circuits.

Technical Specifications

Tick the specs you need, then view products that match.

Voltage 230 V
Phase Single Phase
Poles 1-pole + N
Device Type RCD
Residual Current 100 mA
RCD Type Type A
Manufacturer IMO Precision Controls
Series B10R
Model B10R2040-100-A
Alternative SKU B10R2040100A
Product type Residual Current Device (RCD/RCCB)
Rated current 40 A
Rated residual operating current 100 mA
Residual current type Type A
Pole configuration 1 Pole + Neutral (2 Pole)
Rated voltage 230 V AC
Frequency 50 / 60 Hz
Conditional short-circuit rating 10 kA
Mounting type DIN rail
Protection rating IP20
Standard IEC 61008-1
HS Code 8536201090
Country of Manufacture China

Frequently Asked Questions

What is the IMO B10R2040-100-A used for?

The B10R2040-100-A provides earth leakage protection by disconnecting single-phase electrical circuits when a residual current fault is detected.

What does Type A mean?

Type A RCDs detect both alternating residual currents and pulsating DC residual currents generated by many modern electronic devices and equipment.

What is the current rating?

The IMO B10R2040-100-A has a rated operational current of 40 A.

What residual current sensitivity does it provide?

The device has a 100 mA rated residual operating current for dependable earth leakage protection.

Does this RCD provide overload protection?

No. This device provides residual current protection only and should be installed with a suitably rated miniature circuit breaker or fuse for overload and short-circuit protection.

Trusted Electrical Protection from IMO

IMO B10R residual current devices are trusted by electrical contractors, panel builders and industrial engineers for dependable earth leakage protection and reliable operation across demanding industrial and commercial electrical installations.