B10R2032-30 IMO RCD 10KA, 30mA 1 Pole + N, 32 Amp, 230VAC

B10R2032-30 IMO RCD 10KA, 30mA 1 Pole + N, 32 Amp, 230VAC

SKU: B10R2032-30Alt SKU: B10R203230MPN: B10R2032-30
Price
List Price £40.55 ex VAT
Your Price (ex VAT) Save 30%
£28.39 30% OFF
You save £12.17 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £28.39
Trade pricing is personalised to your account

Manufacturer Lead Time

£28.39

Why Choose the IMO B10R2032-30 Residual Current Device?

The IMO B10R2032-30 is a compact and dependable residual current device (RCD/RCCB) designed to detect earth leakage faults in single-phase electrical installations. Manufactured by IMO Precision Controls, it provides reliable residual current protection for distribution boards, industrial control panels, machinery and commercial electrical systems.

The device continuously monitors the balance between the current flowing through the live and neutral conductors. When an imbalance exceeding the rated residual operating current is detected, the B10R2032-30 disconnects the electrical supply, helping reduce the risks associated with electric shock, insulation failure and earth leakage faults.

With a rated current of 32 A, a sensitive 30 mA residual operating current and a 1 Pole + Neutral configuration, the IMO B10R2032-30 is suitable for single-phase 230 V AC electrical systems. Its compact DIN rail format enables straightforward installation within consumer units, distribution boards and electrical enclosures.

Key Advantages

  • Reliable residual current protection for single-phase electrical circuits.
  • 32 A rated current for commercial and industrial installations.
  • 30 mA residual operating current for enhanced earth leakage protection.
  • 1 Pole + Neutral configuration for 230 V AC systems.
  • 10 kA conditional short-circuit rating.
  • Compact DIN rail design for straightforward installation.

Key Features

  • IMO B10R residual current device series.
  • 32 A rated operational current.
  • 30 mA rated residual operating current.
  • 10 kA conditional short-circuit capacity.
  • 1 Pole + Neutral switching configuration.
  • 230 V AC rated operating voltage.
  • Integrated test function for routine operational checks.
  • Compact DIN rail mounting format.

Dependable Earth Leakage Protection

Residual current devices compare the electrical current travelling through the live conductor with the current returning through the neutral conductor. Under normal operating conditions, these values remain balanced. If current leaks to earth through damaged insulation, faulty equipment or another unintended path, the resulting imbalance causes the RCD to disconnect the supply.

The 30 mA sensitivity of the IMO B10R2032-30 makes it suitable for circuits requiring enhanced residual current protection. The device should be installed alongside appropriately rated overcurrent protection because an RCD does not replace a miniature circuit breaker or fuse.

Typical Applications

  • Single-phase electrical distribution boards.
  • Industrial machinery and control panels.
  • Commercial electrical installations.
  • Socket and equipment supply circuits.
  • Automation and OEM control systems.
  • Circuits requiring 30 mA earth leakage protection.

Technical Specifications

Tick the specs you need, then view products that match.

Voltage 230 V
Phase Single Phase
Poles 2-pole
Device Type RCD
Residual Current 30 mA
Manufacturer IMO Precision Controls
Series B10R
Model B10R2032-30
Product type Residual current device (RCD/RCCB)
Rated current 32 A
Rated residual operating current 30 mA
Pole configuration 1 Pole + Neutral
Number of poles 2
Rated voltage 230 V AC
Frequency 50 / 60 Hz
Conditional short-circuit rating 10 kA
Mounting type DIN rail
Protection rating IP20
Application Earth leakage and residual current protection
HS Code 8536201090
Country of Manufacture China

Frequently Asked Questions

What is the IMO B10R2032-30 used for?

The B10R2032-30 is used to detect residual current and earth leakage faults in single-phase electrical circuits, disconnecting the supply when its rated trip threshold is exceeded.

What is the current rating of this RCD?

The IMO B10R2032-30 has a rated operational current of 32 A.

What residual current sensitivity does it provide?

This device has a rated residual operating current of 30 mA.

What voltage and pole configuration does it use?

The B10R2032-30 is designed for 230 V AC single-phase systems and has a 1 Pole + Neutral configuration.

Does this RCD provide overload protection?

No. The B10R2032-30 provides residual current protection and should be installed with a suitably rated circuit breaker or fuse for overload and short-circuit protection.

Trusted Electrical Protection from IMO

IMO residual current devices are used by electrical contractors, panel builders and industrial engineers to provide dependable earth leakage protection within modern electrical distribution and control systems.