ABB S202-K16 MCB - S200 - 2P - K - 16A

ABB S202-K16 MCB – S200 – 2P – K – 16A

ABB S202-K16 2 pole miniature circuit breaker with 16 A rated current, K trip characteristic and 6 kA breaking capacity for motor control and electrical distribution applications.

SKU: S202-K16Alt SKU: S202-K16MPN: 2CDS252001R0467
Price
List Price £74.19 ex VAT
Your Price (ex VAT) Save 45%
£40.80 45% OFF
You save £33.39 per unit
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £40.80
Trade pricing is personalised to your account

Manufacturer Lead Time

£40.80

Why Choose the ABB S202-K16 Miniature Circuit Breaker?

The ABB S202-K16 is a robust 2 pole miniature circuit breaker (MCB) designed to provide dependable protection against overloads and short circuits in industrial, commercial and residential electrical installations. As part of the trusted ABB System pro M Compact S200 series, it delivers reliable circuit protection in a compact DIN rail mounted design.

Featuring a K trip characteristic, the S202-K16 is specifically developed for circuits with higher inrush currents, making it ideal for motor control circuits, transformers, solenoids and other inductive loads. Its thermal and magnetic tripping mechanisms minimise nuisance tripping during normal equipment start-up while ensuring fast disconnection during fault conditions.

With a 16 A rated current, 2 pole configuration and a 6 kA breaking capacity, the ABB S202-K16 offers reliable protection for industrial machinery, automation systems and electrical distribution installations requiring dependable performance.

Key Advantages

  • Compact 2 pole miniature circuit breaker for reliable circuit protection.
  • 16 A rated current for industrial and commercial applications.
  • K curve tripping characteristic designed for higher inrush current loads.
  • 6 kA breaking capacity for dependable fault interruption.
  • Thermal and magnetic tripping mechanisms provide overload and short circuit protection.
  • Compatible with ABB System pro M Compact accessories.

Key Features

  • ABB System pro M Compact S200 series.
  • 16 A rated current.
  • 2 pole configuration.
  • K tripping characteristic.
  • 6 kA rated short circuit breaking capacity.
  • Current limiting design.
  • DIN rail mounting to IEC 60715.
  • Suitable for industrial, commercial and residential applications.

Reliable Protection for Motor and Control Circuits

Miniature circuit breakers such as the ABB S202-K16 automatically disconnect electrical circuits when overload or short circuit conditions occur. This helps protect wiring, machinery and connected equipment while improving installation safety and reducing downtime.

The K curve characteristic is particularly suitable for protecting motors, transformers and inductive loads that experience temporary inrush currents during start-up, delivering dependable protection without unnecessary interruptions.

Typical Applications

  • Motor control circuits.
  • Industrial automation systems.
  • Electrical control panels.
  • Transformer protection.
  • Machine building.
  • Commercial electrical distribution.

Technical Specifications

Tick the specs you need, then view products that match.

Current 16 A
Phase Single Phase
Poles 2-pole
Device Type MCB
Trip Curve K curve
Breaking Capacity 6 kA
Manufacturer ABB
Series System pro M Compact S200
Model S202-K16
Product ID 2CDS252001R0467
EAN 4016779507417
Product type Miniature circuit breaker (MCB)
Rated current 16 A
Number of poles 2
Tripping characteristic K
Rated operational voltage Up to 440 V AC
Frequency 50 / 60 Hz
Breaking capacity 6 kA
Protection rating IP20 (IP40 when installed in an enclosure)
Mounting type DIN rail
Dimensions (H × W × D) 88 × 35 × 69 mm
Weight Approx. 0.23 kg
HS Code 85362010
Country of Manufacture Germany

Frequently Asked Questions

What is the ABB S202-K16 used for?

The ABB S202-K16 protects electrical circuits against overloads and short circuits, particularly in motor control and inductive load applications.

What does the K trip characteristic mean?

A K curve circuit breaker is designed to tolerate higher inrush currents while still providing reliable overload and short circuit protection.

What is the rated current of the ABB S202-K16?

The ABB S202-K16 has a 16 A rated current.

How many poles does this miniature circuit breaker have?

This model features a 2 pole configuration for switching and protecting two conductors simultaneously.

How is the ABB S202-K16 installed?

The breaker is designed for quick installation onto a standard DIN rail inside distribution boards and electrical control panels.

Trusted by Electrical Professionals Worldwide

ABB System pro M Compact miniature circuit breakers are trusted worldwide by electricians, panel builders and industrial engineers for delivering reliable circuit protection, consistent performance and long service life.