ABB S201MT-K4NAH10 MCB - S200M - 1P+N - K - 4A

ABB S201MT-K4NAH10 MCB – S200M – 1P+N – K – 4A

ABB S201MT-K4NAH10 miniature circuit breaker with switched neutral, 4 A K characteristic and 10 kA breaking capacity for railway, traction and industrial circuit protection.

SKU: S201MT-K4NAH10Alt SKU: S201MT-K4NAH10MPN: 2CDV271106R0337
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the ABB S201MT-K4NAH10 Miniature Circuit Breaker?

The ABB S201MT-K4NAH10 is a high-performance miniature circuit breaker with switched neutral, designed to provide dependable overload and short-circuit protection for railway, traction and demanding industrial electrical systems. As part of the ABB S200MT series, it combines compact construction with robust protection and compliance with recognised railway standards.

Featuring a K tripping characteristic, this MCB is ideal for circuits supplying motors, transformers and other inductive loads with elevated inrush currents. The switched neutral configuration disconnects both the protected conductor and neutral simultaneously, improving circuit isolation and enhancing maintenance safety.

With a 4 A rated current, 10 kA short-circuit breaking capacity and compact DIN rail mounting, the ABB S201MT-K4NAH10 is well suited to industrial automation systems, railway infrastructure, OEM machinery and auxiliary power circuits where dependable electrical protection is essential.

Key Advantages

  • 4 A miniature circuit breaker for low-current protection.
  • K characteristic designed for inductive loads with higher inrush currents.
  • Switched neutral improves electrical isolation.
  • 10 kA breaking capacity for dependable fault protection.
  • Designed for railway, traction and industrial applications.
  • Compact DIN rail mounting saves valuable enclosure space.

Key Features

  • ABB S200MT series.
  • 4 A rated current.
  • 1 protected pole plus switched neutral.
  • K tripping characteristic.
  • 10 kA rated short-circuit breaking capacity.
  • Current limiting miniature circuit breaker.
  • Suitable for 50 / 60 Hz AC systems.
  • Compatible with ABB System pro M compact accessories.

Reliable Protection for Railway and Industrial Systems

The ABB S200MT range has been developed specifically for railway and traction applications while also meeting the requirements of demanding industrial installations. Its current limiting design incorporates delayed thermal overload protection together with an electromechanical short-circuit tripping mechanism for reliable circuit protection.

The K characteristic provides dependable protection for circuits with elevated starting currents, reducing nuisance tripping while maintaining effective fault protection. Combined with its switched neutral configuration and compact modular design, the S201MT-K4NAH10 is an excellent choice for panel builders, OEMs and railway engineers.

Typical Applications

  • Railway and rolling stock electrical systems.
  • Industrial control panels.
  • Motor and transformer protection.
  • Auxiliary power circuits.
  • OEM machinery.
  • Industrial automation systems.

Technical Specifications

Tick the specs you need, then view products that match.

Phase Single Phase
Current 4 A
Poles 1-pole + N
Device Type MCB
Trip Curve K curve
Breaking Capacity 10 kA
Manufacturer ABB
Series S200MT
Model S201MT-K4NAH10
Manufacturer Part Number 2CDV271106R0337
Product type Miniature Circuit Breaker (MCB)
Rated current 4 A
Number of poles 1 protected pole + switched neutral
Tripping characteristic K
Rated operational voltage 230 V AC
Maximum operational voltage 253 V AC
Rated insulation voltage 440 V
Rated impulse withstand voltage 4 kV
Frequency 50 / 60 Hz
Breaking capacity 10 kA
Standards IEC/EN 60898-1, IEC/EN 60947-2
Protection rating IP20
Mounting type DIN rail
Dimensions (H × W × D) approx. 88 × 35 × 69 mm
Weight approx. 0.25 kg

Frequently Asked Questions

What is the ABB S201MT-K4NAH10 used for?

It provides overload and short-circuit protection for railway, industrial and low-current electrical circuits.

What does the K tripping characteristic mean?

The K characteristic is designed for circuits with higher inrush currents, making it suitable for motors, transformers and inductive loads.

What does switched neutral provide?

The switched neutral disconnects the neutral conductor together with the protected pole, improving circuit isolation during maintenance and fault conditions.

What is the breaking capacity of this breaker?

The ABB S201MT-K4NAH10 has a 10 kA rated short-circuit breaking capacity.

Can this MCB be installed on a DIN rail?

Yes. It is designed for standard DIN rail mounting inside electrical control panels and distribution boards.

Trusted by Railway and Industrial Engineers Worldwide

ABB S200MT miniature circuit breakers are trusted worldwide for reliable circuit protection, robust construction and dependable performance in demanding railway and industrial environments.