ABB S201MT-K16NAH10 MCB - S200M - 1P+N - K - 16A

ABB S201MT-K16NAH10 MCB – S200M – 1P+N – K – 16A

ABB S201MT-K16NAH10 miniature circuit breaker with switched neutral, 16 A K characteristic and 10 kA breaking capacity for railway, traction and industrial circuit protection.

SKU: S201MT-K16NAH10Alt SKU: S201MT-K16NAH10MPN: 2CDV271106R0467
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the ABB S201MT-K16NAH10 Miniature Circuit Breaker?

The ABB S201MT-K16NAH10 is a high-performance miniature circuit breaker with switched neutral, designed to provide dependable overload and short-circuit protection for railway, traction and demanding industrial electrical systems. As part of the ABB S200MT series, it combines compact installation, robust construction and reliable protection for specialist electrical applications.

Featuring a K tripping characteristic, this MCB is ideal for circuits with higher inrush currents, including motors, transformers, inductive loads and auxiliary control circuits. The switched neutral configuration disconnects both the protected conductor and neutral simultaneously, improving circuit isolation and simplifying maintenance procedures.

With a 16 A rated current, 10 kA rated short-circuit breaking capacity and DIN rail mounting, the ABB S201MT-K16NAH10 is well suited to railway systems, industrial automation, OEM machinery and control panels where reliable electrical protection is essential.

Key Advantages

  • 16 A miniature circuit breaker for railway and industrial protection.
  • K characteristic designed for circuits with higher inrush currents.
  • Switched neutral configuration provides improved circuit isolation.
  • 10 kA breaking capacity for dependable fault protection.
  • Designed specifically for railway, traction and industrial applications.
  • Compact DIN rail mounting simplifies installation.

Key Features

  • ABB S200MT series.
  • 16 A rated current.
  • 1 protected pole plus switched neutral.
  • K tripping characteristic.
  • 10 kA rated short-circuit breaking capacity.
  • Current limiting miniature circuit breaker design.
  • Suitable for 50 / 60 Hz AC systems.
  • Compatible with ABB System pro M Compact accessories.

Reliable Protection for Railway and Industrial Systems

The ABB S200MT range has been developed specifically for traction and railway applications while also meeting the requirements of demanding industrial installations. Its current limiting design incorporates delayed thermal overload protection together with an electromechanical short-circuit tripping mechanism, delivering reliable protection for modern electrical systems.

The K characteristic allows the S201MT-K16NAH10 to operate reliably on circuits with elevated starting currents while reducing nuisance tripping. Combined with its switched neutral configuration and compatibility with ABB System pro M Compact accessories, it provides an excellent solution for panel builders, OEMs and railway engineers.

Typical Applications

  • Railway and rolling stock electrical systems.
  • Industrial control panels.
  • Motor and transformer protection.
  • Auxiliary power circuits.
  • OEM machinery.
  • Industrial automation systems.

Technical Specifications

Tick the specs you need, then view products that match.

Phase Single Phase
Current 16 A
Poles 1-pole + N
Device Type MCB
Trip Curve K curve
Breaking Capacity 10 kA
Manufacturer ABB
Series S200MT
Model S201MT-K16NAH10
Manufacturer Part Number 2CDV271106R0467
Product type Miniature Circuit Breaker (MCB)
Rated current 16 A
Number of poles 1 protected pole + switched neutral
Tripping characteristic K
Rated operational voltage 230 V AC
Input voltage type AC/DC
Rated insulation voltage 440 V
Rated impulse withstand voltage 4 kV
Frequency 50 / 60 Hz
Breaking capacity 10 kA
Rated ultimate breaking capacity (Icu) 15 kA
Protection rating IP20
Mounting type DIN rail
Dimensions (H × W × D) approx. 88 × 35 × 69 mm
Weight approx. 0.25 kg

Frequently Asked Questions

What is the ABB S201MT-K16NAH10 used for?

It provides overload and short-circuit protection for railway, traction, industrial and auxiliary electrical circuits.

What does the 16 A rating mean?

The 16 A rated current means the breaker is designed to protect circuits carrying up to 16 amps under normal operating conditions.

What does switched neutral mean?

The switched neutral disconnects the neutral conductor together with the protected pole, providing improved circuit isolation and increased maintenance safety.

What is the K tripping characteristic suitable for?

The K curve is designed for circuits with higher inrush currents, making it suitable for motors, transformers, inductive loads and specialist industrial equipment.

Can the ABB S201MT-K16NAH10 be DIN rail mounted?

Yes. It is designed for standard DIN rail mounting inside electrical control panels and distribution boards.

Trusted by Railway and Industrial Engineers Worldwide

ABB S200MT miniature circuit breakers are trusted worldwide for dependable circuit protection, robust construction and reliable performance in demanding railway and industrial environments.