ABB S201M-D10NA MCB - S200M - 1P+N - D - 10A

ABB S201M-D10NA MCB – S200M – 1P+N – D – 10A

ABB S201M-D10NA 1P+N miniature circuit breaker with 10 A rated current, D tripping characteristic and 10 kA breaking capacity for circuits with high inrush currents.

SKU: S201M-D10NAAlt SKU: S201M-D10NAMPN: 2CDS271103R0101
Price
List Price £61.26 ex VAT
Your Price (ex VAT) Save 45%
£33.69 45% OFF
You save £27.57 per unit
Manufacturer Lead Time Estimated Delivery 14 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £33.69
Trade pricing is personalised to your account

Manufacturer Lead Time

£33.69

Why Choose the ABB S201M-D10NA Miniature Circuit Breaker?

The ABB S201M-D10NA is a dependable 1P+N miniature circuit breaker (MCB) from the ABB System pro M compact S200M series. Designed to protect electrical circuits against overloads and short circuits, it provides reliable performance for residential, commercial and industrial installations.

Featuring a D tripping characteristic, the S201M-D10NA is suitable for circuits with high inrush currents, including motors, transformers, control equipment and inductive loads. Its current limiting design helps reduce fault energy, while delayed thermal and electromechanical trip mechanisms provide effective protection during overload and short circuit conditions.

Rated at 10 A with a 10 kA short circuit breaking capacity, this compact 1P+N MCB is designed for DIN rail installation in distribution boards and control panels. It is part of ABB’s proven modular circuit protection range and supports safe, efficient electrical system design.

Key Advantages

  • Compact 1P+N miniature circuit breaker for reliable circuit protection.
  • 10 A rated current for industrial and control circuit applications.
  • D curve tripping characteristic for high inrush current loads.
  • 10 kA breaking capacity for robust short circuit protection.
  • Current limiting design helps minimise fault energy.
  • Suitable for residential, commercial and industrial installations.

Key Features

  • ABB System pro M compact S200M series.
  • Model: S201M-D10NA.
  • Product ID: 2CDS271103R0101.
  • 10 A rated current.
  • D tripping characteristic.
  • 1P+N configuration.
  • 10 kA rated short circuit breaking capacity.
  • DIN rail mounting for distribution boards and control panels.

Reliable Protection for High Inrush Current Circuits

The ABB S201M-D10NA combines delayed thermal overload protection with electromechanical short circuit protection. This dual tripping technology helps protect wiring, equipment and connected loads from electrical faults while supporting safe system operation.

Its D curve characteristic makes it particularly suited to circuits where brief high starting currents are expected during normal operation, such as motor loads, transformers and industrial control equipment.

Typical Applications

  • Motor control circuits.
  • Transformer protection.
  • Industrial machinery.
  • Control panels and automation systems.
  • Commercial distribution boards.
  • Electrical installations with high inrush current loads.

Technical Specifications

Tick the specs you need, then view products that match.

Current 10 A
Phase Single Phase
Poles 1-pole + N
Device Type MCB
Trip Curve D curve
Breaking Capacity 10 kA
Manufacturer ABB
Series System pro M compact S200M
Model S201M-D10NA
Product ID 2CDS271103R0101
EAN 4016779599948
Product type Miniature Circuit Breaker (MCB)
Rated current 10 A
Tripping characteristic D
Number of poles 1P+N
Rated operational voltage 230 V AC
Frequency 50 / 60 Hz
Rated short circuit capacity 10 kA
Protection rating IP20
Mounting type DIN rail
Dimensions (W × H × D) approx. 35 × 88 × 69 mm
Standards IEC/EN 60898-1, IEC/EN 60947-2, UL 1077
HS Code 85362010
Country of Manufacture Germany

Frequently Asked Questions

What is the ABB S201M-D10NA used for?

The S201M-D10NA is used to protect electrical circuits against overloads and short circuits, particularly in applications with high inrush currents.

What does the D curve tripping characteristic mean?

A D curve miniature circuit breaker is designed for circuits with high starting currents, making it suitable for motors, transformers and inductive loads.

What is the rated current of the S201M-D10NA?

The ABB S201M-D10NA has a rated current of 10 A.

What is the short circuit breaking capacity?

This miniature circuit breaker provides a rated short circuit breaking capacity of 10 kA.

How is the ABB S201M-D10NA installed?

The breaker is designed for DIN rail mounting inside electrical distribution boards, control panels and machine cabinets.

Trusted by Electrical Professionals Worldwide