ABB F204 AC S-40/0.5 RCD - 4P - Type AC Selective - 40A - 500mA

ABB F204 AC S-40/0.5 RCD – 4P – Type AC Selective – 40A – 500mA

ABB F204ACS-40/0.5 4 pole Type AC residual current circuit breaker with 40 A rated current and 500 mA sensitivity for commercial and industrial electrical protection.

SKU: F204ACS-40/0.5Alt SKU: F204ACS-40/0.5MPN: 2CSF204901R4400
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the ABB F204ACS-40/0.5 Residual Current Circuit Breaker?

The ABB F204ACS-40/0.5, also known as F204 AC-40/0.5, is a high quality 4 pole residual current circuit breaker (RCCB) designed to protect people and electrical installations against earth fault currents. As part of the proven ABB F200 series, it delivers dependable earth leakage protection for commercial, industrial and infrastructure electrical systems.

This RCCB features Type AC residual current protection, making it suitable for detecting alternating sinusoidal residual currents. With a 500 mA residual operating current, it is commonly installed for upstream fault protection and fire protection in electrical distribution systems, helping minimise damage caused by insulation faults.

With a 40 A rated current, 500 mA residual current sensitivity and 4 pole configuration, the ABB F204ACS-40/0.5 is ideal for protecting three phase distribution boards, industrial control panels and commercial electrical installations.

Key Advantages

  • Professional 4 pole RCCB for three phase electrical installations.
  • 40 A rated current for commercial and industrial distribution circuits.
  • 500 mA residual current sensitivity for fault protection and fire protection.
  • Type AC residual current protection for alternating sinusoidal earth leakage currents.
  • Instantaneous operating characteristic for rapid fault disconnection.
  • Compact DIN rail mounting design for modern distribution boards.

Key Features

  • ABB F200 residual current circuit breaker series.
  • F204 AC-40/0.5 model designation.
  • 40 A rated current.
  • 500 mA residual operating current.
  • 4 pole configuration.
  • Type AC earth leakage protection.
  • Instantaneous tripping characteristic.
  • DIN rail mounting with screw terminals.

Reliable Type AC Earth Leakage Protection

Residual current circuit breakers continuously monitor the balance of current flowing through live conductors and disconnect the electrical supply whenever earth leakage is detected. This helps protect electrical installations from insulation faults while reducing the risk of fire and equipment damage.

The ABB F204ACS-40/0.5 provides dependable Type AC protection for standard AC electrical installations. Its 500 mA sensitivity makes it particularly suitable for upstream protection and fire protection within commercial and industrial distribution systems.

Typical Applications

  • Commercial electrical distribution boards.
  • Industrial switchboards and control panels.
  • Three phase power distribution systems.
  • Building services installations.
  • Infrastructure electrical systems.
  • Installations requiring 500 mA Type AC residual current protection.

Technical Specifications

Tick the specs you need, then view products that match.

Product Series ABB F200
Current 40 A
Phase Three Phase
Poles 4-pole
Device Type RCD
Residual Current 500 mA
RCD Type Type AC
Model F204ACS-40/0.5
Manufacturer ABB
Series F200
Product ID 2CSF204001R4400
EAN 8012542782209
Product type Residual Current Circuit Breaker (RCCB)
Rated current 40 A
Rated residual operating current 500 mA
Residual current type Type AC
Operating characteristic Instantaneous
Number of poles 4
Rated voltage 230/400 V AC
Maximum operating voltage 480Y / 277 V AC
Frequency 50 / 60 Hz
Rated conditional short-circuit current 10 kA
Maximum surge current 0.25 kA
Protection rating IP20
Mounting type DIN rail
Dimensions (H × W × D) approx. 85 × 70 × 69 mm
Weight approx. 0.36 kg

Frequently Asked Questions

What is the ABB F204ACS-40/0.5 used for?

It provides Type AC residual current protection against earth leakage faults in commercial, industrial and infrastructure electrical installations.

What is the rated current of this RCCB?

The ABB F204ACS-40/0.5 has a 40 A rated current.

What residual current sensitivity does this model provide?

This model provides 500 mA residual current sensitivity, making it suitable for fault protection and fire protection applications.

What does Type AC protection mean?

Type AC protection detects alternating sinusoidal residual currents found in conventional AC electrical installations.

Where is this RCCB typically installed?

It is commonly installed on a DIN rail within commercial distribution boards, industrial control panels and electrical switchboards.

Trusted by Electrical Professionals Worldwide

ABB F200 residual current circuit breakers are trusted by electrical contractors, panel builders and industrial engineers for reliable earth leakage protection, robust construction and dependable long-term performance.