ABB F204 AC-80/0.3 L RCD - 4P - Type AC - 80A - 300mA

ABB F204 AC-80/0.3 L RCD – 4P – Type AC – 80A – 300mA

ABB F204 AC-80/0.3 L four pole Type AC residual current circuit breaker with 80 A rated current and 300 mA residual operating current for commercial and industrial electrical protection.

SKU: F204 AC-80/0.3 LAlt SKU: F204 AC-80/0.3-LMPN: 2CSF204023R3800
Price
List Price £280.65 ex VAT
Your Price (ex VAT) Save 35%
£182.42 35% OFF
You save £98.23 per unit
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £182.42
Trade pricing is personalised to your account

Manufacturer Lead Time

£182.42

Why Choose the ABB F204 AC-80/0.3 L Residual Current Circuit Breaker?

The ABB F204 AC-80/0.3 L is a premium 4 pole residual current circuit breaker (RCCB) engineered to provide dependable protection against earth leakage faults in commercial, industrial and infrastructure electrical installations. As part of the trusted ABB F200 Series, it delivers reliable protection for both personnel and equipment while helping installations comply with modern electrical safety standards.

Featuring an 80 A rated current and a 300 mA rated residual operating current, this RCCB is ideal for three-phase distribution systems requiring dependable earth fault protection. Its Type AC operating characteristic detects alternating sinusoidal residual currents, reducing the risk of electric shock and helping minimise fire hazards caused by insulation failures.

The L variant incorporates a left-hand neutral terminal configuration, making it suitable for installations where this wiring arrangement is specified. Designed for DIN rail mounting, the F204 AC-80/0.3 L offers robust construction, long mechanical life and compatibility with a comprehensive range of ABB accessories.

Key Advantages

  • Reliable 4 pole RCCB for commercial and industrial electrical installations.
  • 80 A rated current suitable for higher-load distribution circuits.
  • 300 mA residual operating current for earth fault and fire protection.
  • Type AC protection for alternating sinusoidal residual currents.
  • Left-hand neutral terminal for specific panel wiring layouts.
  • Compact DIN rail mounting with ABB quality and reliability.

Key Features

  • ABB F200 Series RCCB.
  • 80 A rated current.
  • 300 mA rated residual current.
  • 4 pole configuration.
  • Type AC residual current detection.
  • 230/400 V AC rated operational voltage.
  • 50 / 60 Hz operation.
  • Instantaneous operating characteristic.
  • DIN rail mounting.
  • Screw terminal connections.

Reliable Earth Leakage Protection

Residual current circuit breakers continuously monitor the balance between outgoing and returning current. If an earth leakage fault occurs, the RCCB disconnects the circuit almost instantly, helping to protect personnel from electric shock while reducing the likelihood of electrical fires caused by insulation breakdown.

The ABB F200 Series is widely specified for industrial control panels, commercial distribution boards and infrastructure projects where dependable performance, long service life and easy installation are essential.

Typical Applications

  • Commercial electrical distribution boards.
  • Industrial switchgear and control panels.
  • Manufacturing and processing facilities.
  • Infrastructure and public buildings.
  • Three-phase power distribution systems.
  • Electrical installations requiring left-hand neutral RCCBs.

Technical Specifications

Tick the specs you need, then view products that match.

Product Series ABB F200
Current 80 A
Phase Three Phase
Poles 4-pole
Device Type RCD
Residual Current 300 mA
RCD Type Type AC
Manufacturer ABB
Series F200 RCCB Series
Model F204 AC-80/0.3 L
Product ID 2CSF204023R3800
Product type Residual Current Circuit Breaker (RCCB)
Rated current 80 A
Rated residual operating current 300 mA
Residual current type Type AC
Rated operational voltage 230 / 400 V AC
Rated insulation voltage 500 V
Frequency 50 / 60 Hz
Number of poles 4
Operating characteristic Instantaneous
Rated conditional short-circuit current 10 kA
Maximum surge current 0.25 kA
Protection rating IP2X
Mounting type DIN rail
Neutral terminal position Left
Dimensions (H × W × D) 85 × 70 × 69 mm
Weight Approx. 0.38 kg
Standards IEC/EN 61008

Frequently Asked Questions

What is the ABB F204 AC-80/0.3 L used for?

It provides earth leakage protection by disconnecting the electrical supply when a residual current fault is detected, helping protect people and electrical installations.

What does the 300 mA residual current rating mean?

A 300 mA sensitivity is commonly specified for equipment and fire protection applications where higher residual current thresholds are appropriate.

What type of residual current does this RCCB detect?

The ABB F204 AC-80/0.3 L is a Type AC RCCB designed to detect alternating sinusoidal residual currents.

What does the L designation indicate?

The L version features the neutral terminal positioned on the left-hand side to suit specific switchboard wiring configurations.

Where is this RCCB typically installed?

It is designed for DIN rail mounting inside commercial and industrial distribution boards, switchgear and electrical control panels.

Trusted by Electrical Professionals Worldwide

ABB F200 Series residual current circuit breakers are trusted by electricians, panel builders and industrial engineers worldwide for dependable earth leakage protection, high build quality and long-term reliability.