ABB F202 AC-80/0.1 RCD - 2P - Type AC - 80A - 100mA

ABB F202 AC-80/0.1 RCD – 2P – Type AC – 80A – 100mA

ABB F202 AC-80/0.1 residual current circuit breaker from the F200 series, a 2-pole Type AC 80 A RCCB with 100 mA residual current sensitivity for earth leakage protection in electrical installations.

SKU: F202 AC-80/0,1Alt SKU: F202 AC-80/0.1MPN: 2CSF202001R2800
Price
List Price £176.75 ex VAT
Your Price (ex VAT) Save 35%
£114.89 35% OFF
You save £61.86 per unit
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £114.89
Trade pricing is personalised to your account

Manufacturer Lead Time

£114.89

Why Choose the ABB F202 AC-80/0.1 Residual Current Circuit Breaker?

The ABB F202 AC-80/0.1 is a high-quality 2-pole residual current circuit breaker (RCCB) designed to provide dependable protection against earth fault currents in electrical installations. As part of the trusted ABB F200 series, it monitors leakage current and disconnects the electrical supply when a residual current fault is detected, helping protect wiring, equipment and people from hazardous fault conditions.

This RCCB features a Type AC residual current characteristic, making it suitable for detecting sinusoidal alternating residual currents in standard AC electrical systems. With a rated residual operating current of 100 mA, the F202 AC-80/0.1 is suitable for applications where a higher residual current threshold is required for installation and equipment protection.

With a rated current of 80 A, a 2-pole configuration and DIN rail mounting, the ABB 2CSF202001R2800 is ideal for consumer units, distribution boards, switchboards and industrial control panels. Its compact modular design supports straightforward installation within modern electrical distribution systems.

Key Advantages

  • Compact 2-pole residual current circuit breaker for earth leakage protection.
  • 80 A rated current suitable for higher current protected circuits.
  • 100 mA residual current sensitivity for specified earth fault protection applications.
  • Type AC protection for sinusoidal AC residual currents.
  • DIN rail mounted design for quick installation in modular panels.
  • Part of the reliable ABB F200 RCCB series.

Key Features

  • ABB F200 series RCCB.
  • 2-pole residual current circuit breaker.
  • 80 A rated current.
  • 100 mA rated residual operating current.
  • Type AC residual current detection.
  • Instantaneous operating characteristic.
  • DIN rail mounting for modular electrical panels.
  • Designed to protect installations against earth fault current.

Reliable Earth Leakage Protection for Electrical Installations

Residual current circuit breakers such as the ABB F202 AC-80/0.1 compare the current flowing through live and neutral conductors. If leakage current to earth exceeds the rated operating threshold, the RCCB disconnects the supply to help reduce the risk of electrical shock, insulation fault damage and unsafe operating conditions.

The 100 mA sensitivity makes this RCCB suitable for installations requiring residual current protection at a higher trip level than 30 mA devices. Its 2-pole design disconnects both live and neutral conductors, supporting safe isolation in single-phase electrical distribution systems.

Typical Applications

  • Residential consumer units and distribution boards.
  • Commercial electrical distribution systems.
  • Sub-distribution and feeder circuits.
  • General-purpose earth leakage protection.
  • Industrial control panels and switchboards.
  • Single-phase installations requiring 2-pole residual current protection.

Technical Specifications

Tick the specs you need, then view products that match.

Product Series ABB F200
Current 80 A
Poles 2-pole
Residual Current 100 mA
RCD Type Type AC
Device Type RCD
Manufacturer ABB
Series F200
Model F202 AC-80/0.1
Product ID 2CSF202001R2800
EAN 8012542914402
Product type Residual current circuit breaker
Number of poles 2P
Rated current 80 A
Rated residual operating current 100 mA
Residual current type Type AC
Operating characteristic Instantaneous
Rated operational voltage 230 / 400 V AC
Rated insulation voltage 500 V
Rated conditional short-circuit current 10 kA
Rated impulse withstand voltage 4 kV
Frequency 50 / 60 Hz
Protection rating IP20 terminals, IP40 housing
Mounting type DIN rail mounting
Terminal type Screw terminals
Dimensions (H × W × D) approx. 85 × 35 × 69 mm
Weight approx. 0.20 kg
Standards IEC/EN 61008, UL 1053

Frequently Asked Questions

What is the ABB F202 AC-80/0.1 used for?

The ABB F202 AC-80/0.1 is used to provide residual current protection by disconnecting a circuit when earth leakage current is detected.

What current rating does this RCCB have?

The ABB F202 AC-80/0.1 has a rated current of 80 A.

What residual current sensitivity does it provide?

This RCCB has a rated residual operating current of 100 mA.

What does Type AC mean on this device?

Type AC means the device is designed to detect sinusoidal alternating residual currents in standard AC electrical installations.

Where is the ABB F202 AC-80/0.1 typically installed?

It is typically installed on a DIN rail inside consumer units, distribution boards, switchboards, control panels or modular electrical enclosures.

Trusted by Electrical Professionals Worldwide

ABB F200 residual current circuit breakers are widely used by electricians, panel builders and maintenance engineers for dependable earth leakage protection across residential, commercial and industrial electrical installations.