ABB F202AC-63/0.3 RCD - 2P - Type AC - 63A - 300mA

ABB F202AC-63/0.3 RCD – 2P – Type AC – 63A – 300mA

ABB F202 AC-63/0,3 2 pole Type AC residual current circuit breaker rated at 63 A with 300 mA residual current sensitivity for commercial and industrial electrical installations.

SKU: 2CSF202001R3630Alt SKU: F202 AC-63/0.3MPN: 2CSF202001R3630
Price
List Price £153.70 ex VAT
Your Price (ex VAT) Save 35%
£99.91 35% OFF
You save £53.80 per unit
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £99.91
Trade pricing is personalised to your account

Manufacturer Lead Time

£99.91

Why Choose the ABB F202 AC-63/0,3 Residual Current Circuit Breaker?

The ABB F202 AC-63/0,3 is a high performance residual current circuit breaker (RCCB) designed to provide reliable protection against earth leakage faults in commercial, industrial and building electrical installations. As part of the trusted ABB F200 series, it disconnects the electrical supply when dangerous residual currents are detected, helping to improve electrical safety and protect equipment.

This 2-pole Type AC RCCB is suitable for single-phase AC systems where protection against sinusoidal alternating residual currents is required. With a 63 A rated current and 300 mA residual operating current, it is ideal for feeder circuits, distribution boards and industrial installations requiring dependable earth fault protection.

Featuring a compact DIN rail mounted design, durable screw terminals and ABB's proven engineering, the F202 AC-63/0,3 offers straightforward installation together with long service life in demanding electrical environments.

Key Advantages

  • Reliable ABB F200 series RCCB.
  • 63 A rated current for higher load circuits.
  • 300 mA residual current sensitivity.
  • 2-pole Type AC earth leakage protection.
  • Compact DIN rail mounting.
  • Suitable for commercial and industrial electrical installations.

Key Features

  • ABB F202 AC-63/0,3 residual current circuit breaker.
  • F200 modular protection series.
  • 63 A rated current.
  • 300 mA rated residual current.
  • 2-pole construction.
  • Type AC residual current detection.
  • Instantaneous operating characteristic.
  • Screw terminal connections.
  • DIN rail mounting.

Reliable Earth Leakage Protection

Residual current circuit breakers continuously monitor the balance between live and neutral conductors. If an earth leakage fault is detected, the RCCB disconnects the supply rapidly to help reduce the risk of electric shock and minimise damage caused by insulation faults or earth leakage currents.

The ABB F202 AC-63/0,3 is intended for use alongside appropriately rated miniature circuit breakers or fuses, providing dependable residual current protection for modern electrical installations.

Typical Applications

  • Commercial electrical distribution boards.
  • Industrial switchboards.
  • Building services installations.
  • Machinery and equipment power distribution.
  • Control panels.
  • General single-phase AC distribution circuits.

Technical Specifications

Tick the specs you need, then view products that match.

Product Series ABB F200
Current 63 A
Poles 2-pole
Device Type RCD
Residual Current 300 mA
RCD Type Type AC
Manufacturer ABB
Series F200
Model F202 AC-63/0,3
Product ID 2CSF202001R3630
EAN 8012542780809
Product type Residual Current Circuit Breaker (RCCB)
Number of poles 2
Rated current 63 A
Rated residual current 300 mA
Residual current type Type AC
Rated operational voltage 230 / 400 V AC
Frequency 50 / 60 Hz
Rated insulation voltage 500 V
Rated impulse withstand voltage 4 kV
Rated conditional short-circuit current 10 kA
Protection rating IP20 terminals / IP40 housing
Mounting type DIN rail
Operating temperature -25°C to +55°C
Dimensions (H × W × D) 85 × 35 × 69 mm
Weight approx. 0.20 kg
Standards IEC/EN 61008, UL 1053

Frequently Asked Questions

What is the ABB F202 AC-63/0,3 used for?

It provides residual current protection by disconnecting electrical circuits when earth leakage currents exceed 300 mA.

What current rating does this RCCB have?

The ABB F202 AC-63/0,3 has a rated current of 63 A.

What type of residual current does it detect?

This model is a Type AC RCCB designed to detect sinusoidal alternating residual currents.

Does this device provide overload protection?

No. An RCCB provides earth leakage protection only and should be installed together with a suitable circuit breaker or fuse.

Where is the ABB F202 AC-63/0,3 typically installed?

It is commonly installed on DIN rails within distribution boards, switchboards and industrial control panels.

Trusted by Electrical Professionals Worldwide

ABB F200 series RCCBs are trusted by electrical contractors, panel builders and industrial engineers for dependable earth leakage protection across commercial and industrial installations.