ABB F202 AC-40/0.5 RCD - 2P - Type AC - 40A - 500mA

ABB F202 AC-40/0.5 RCD – 2P – Type AC – 40A – 500mA

ABB F202 AC-40/0,5 residual current circuit breaker from the F200 series, a 2 pole Type AC RCCB rated at 40 A with 500 mA residual current sensitivity for DIN rail electrical distribution applications.

SKU: F202 AC-40/0.5Alt SKU: F202 AC-40/0.5MPN: 2CSF202001R4400
Price
List Price £178.12 ex VAT
Your Price (ex VAT) Save 35%
£115.78 35% OFF
You save £62.34 per unit
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £115.78
Trade pricing is personalised to your account

Manufacturer Lead Time

£115.78

Why Choose the ABB F202 AC-40/0,5 Residual Current Circuit Breaker?

The ABB F202 AC-40/0,5 is a reliable residual current circuit breaker (RCCB) designed to provide dependable protection against earth leakage faults in electrical distribution systems. As part of the trusted ABB F200 series, it helps protect people and installations by detecting fault current to earth and disconnecting the circuit when the rated residual current threshold is exceeded.

This 2-pole Type AC residual current device is suitable for single-phase AC systems where protection against sinusoidal alternating residual currents is required. With a 40 A rated current and 500 mA residual current sensitivity, it is well suited for commercial, industrial and building services applications requiring robust earth fault protection.

The ABB F202 AC-40/0,5 features a compact modular design for DIN rail mounting, making it easy to install in distribution boards, switchboards and control panels. Its screw terminal connections and ABB engineering support secure installation and long term performance in demanding electrical environments.

Key Advantages

  • Reliable ABB F200 series RCCB for residual current protection.
  • 2-pole configuration suitable for single-phase electrical circuits.
  • 40 A rated current for protected distribution applications.
  • 500 mA residual current sensitivity for earth fault protection.
  • Type AC detection for sinusoidal alternating residual currents.
  • Compact DIN rail mounting for distribution boards and control panels.

Key Features

  • ABB F202 AC-40/0,5 residual current circuit breaker.
  • F200 series modular residual current device.
  • 40 A rated current.
  • 500 mA rated residual current.
  • 2-pole design.
  • Type AC residual current protection.
  • Instantaneous operating characteristic.
  • Screw terminal connection for secure wiring.
  • DIN rail mounting for fast panel installation.

Reliable Earth Fault Protection for Electrical Installations

Residual current circuit breakers monitor the balance between live and neutral conductors. If earth leakage current is detected, the RCCB disconnects the circuit to help reduce the risk of electric shock, insulation fault damage and fire hazards caused by residual current faults.

The ABB F202 AC-40/0,5 is designed for installations requiring dependable residual current protection without integrated overcurrent protection. It should be used alongside suitably rated circuit breakers or protective devices to provide complete circuit protection.

Typical Applications

  • Commercial electrical distribution boards.
  • Industrial switchboards and control panels.
  • Single-phase power distribution systems.
  • Building services and electrical installation protection.
  • Electrical circuits requiring 500 mA residual current protection.
  • DIN rail mounted modular protection assemblies.

Technical Specifications

Tick the specs you need, then view products that match.

Product Series ABB F200
Current 40 A
Poles 2-pole
Device Type RCD
Residual Current 500 mA
RCD Type Type AC
Manufacturer ABB
Series F200
Model F202 AC-40/0,5
Product type Residual current circuit breaker / RCCB
Product ID 2CSF202001R4400
EAN 8012542781004
Number of poles 2
Rated current 40 A
Rated residual current 500 mA
Residual current type Type AC
Rated operational voltage 230 / 400 V AC
Rated insulation voltage 500 V
Rated impulse withstand voltage 4 kV
Frequency 50 / 60 Hz
Rated conditional short-circuit current 10 kA
Operating characteristic Instantaneous
Standards IEC/EN 61008, UL 1053
Mounting type DIN rail
Terminal type Screw terminals
Protection rating IP20 terminals / IP40 housing
Width in modules 2
Operating temperature -25°C to +55°C
Dimensions (H × W × D) approx. 85 × 35 × 69 mm
Weight approx. 0.20 kg

Frequently Asked Questions

What is the ABB F202 AC-40/0,5 used for?

The ABB F202 AC-40/0,5 is used to provide residual current protection in electrical installations by detecting earth leakage faults and disconnecting the circuit when required.

What current rating does this RCCB have?

This RCCB has a rated current of 40 A, making it suitable for protected single-phase distribution applications.

What residual current sensitivity does the device provide?

The F202 AC-40/0,5 has a rated residual current sensitivity of 500 mA.

What does Type AC mean on this ABB RCCB?

Type AC means the device is designed to detect sinusoidal alternating residual currents commonly found in standard AC electrical circuits.

Does this RCCB provide overload protection?

No. This is a residual current circuit breaker and does not provide overcurrent or short-circuit protection. It should be installed with suitable circuit protection devices.

Trusted by Electrical Installers Worldwide

ABB F200 series residual current devices are widely used by electrical contractors, panel builders and facilities engineers for reliable earth fault protection in commercial and industrial installations.