ABB F202 RCD - 2P - Type A - 100A - 100mA

ABB F202 RCD – 2P – Type A – 100A – 100mA

ABB F202 A-100/0.1 residual current circuit breaker, a 2-pole Type A RCCB with 100 A rated current and 100 mA residual operating current for earth leakage protection in electrical installations.

SKU: 2CSF202101R2900Alt SKU: F202 A-100/0.1MPN: 2CSF202101R2900
Price
List Price £293.94 ex VAT
Your Price (ex VAT) Save 35%
£191.06 35% OFF
You save £102.88 per unit
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £191.06
Trade pricing is personalised to your account

Manufacturer Lead Time

£191.06

Why Choose the ABB F202 A-100/0.1 Residual Current Circuit Breaker?

The ABB F202 A-100/0.1 is a reliable 2-pole residual current circuit breaker (RCCB) designed to protect people, equipment and electrical installations against earth leakage faults. Identified by ABB product code 2CSF202101R2900, this device forms part of the trusted ABB F200 RCCB series, widely used in residential, commercial and industrial distribution systems.

This Type A RCCB detects alternating residual currents and pulsating DC residual currents, making it suitable for circuits supplying modern electrical and electronic loads. Its compact modular format, robust terminal design and DIN rail mounting make it straightforward to install within distribution boards, control panels and switchgear assemblies.

With a rated current of 100 A and a 100 mA residual operating current, the ABB F202 A-100/0.1 is ideal for higher-load circuits where dependable earth leakage protection is required. The device provides instantaneous residual current protection and supports safe, compliant electrical installations.

Key Advantages

  • High-quality ABB 2-pole Type A RCCB for earth leakage protection.
  • 100 A rated current suitable for higher-load electrical circuits.
  • 100 mA trip sensitivity for residual current fault protection.
  • Detects AC and pulsating DC residual currents.
  • Compact DIN rail mounted residual current device.
  • Designed for residential, commercial and industrial distribution systems.

Key Features

  • ABB F200 residual current circuit breaker series.
  • 2-pole RCCB configuration.
  • 100 A rated current.
  • 100 mA rated residual operating current.
  • Type A residual current detection.
  • Instantaneous tripping performance.
  • Toggle switch actuator.
  • Screw terminal connection.
  • DIN rail mounting for modular distribution boards.

Reliable Earth Leakage Protection for Electrical Installations

Residual current circuit breakers monitor the balance of current flowing through live and neutral conductors. If an imbalance occurs due to leakage current to earth, the RCCB disconnects the circuit quickly, helping reduce the risk of electric shock, insulation damage and electrical fire.

The ABB F200 series is engineered for dependable residual current protection across a wide range of installations. The F202 A-100/0.1 provides robust protection for high-current circuits while maintaining a compact two-module DIN rail footprint, making it a practical choice for professional electrical distribution applications.

Typical Applications

  • Commercial distribution boards.
  • Industrial control panels and switchgear.
  • Building services and infrastructure systems.
  • Residential consumer units requiring higher current protection.
  • Power distribution circuits with earth leakage protection requirements.
  • Electrical installations supplying equipment with electronic components.

Technical Specifications

Tick the specs you need, then view products that match.

Product Series ABB F200
Current 100 A
Poles 2-pole
Device Type RCD
Residual Current 100 mA
RCD Type Type A
Manufacturer ABB
Series F200
Model F202 A-100/0.1
Product code 2CSF202101R2900
Product type Residual Current Circuit Breaker (RCCB)
Number of poles 2
Rated current 100 A
Rated residual current 100 mA
Residual current type Type A
Rated operational voltage 277 V AC
Typical rated AC voltage 230 V AC
Frequency 50 / 60 Hz
Standards IEC/EN 61008, UL 1053
Mounting type DIN rail
Terminal type Screw terminal
Actuator type Toggle switch
Break time Instantaneous
Degree of protection IP2X terminals / IP40 housing
Operating temperature -25 to +55 °C
Dimensions (H × W × D) approx. 85 × 35 × 69 mm
HS Code 85363030
Country of Manufacture Italy

Frequently Asked Questions

What is the ABB F202 A-100/0.1 used for?

The ABB F202 A-100/0.1 is used to protect electrical installations against earth leakage faults by disconnecting the circuit when residual current is detected.

What is the rated current of this RCCB?

This RCCB has a 100 A rated current, making it suitable for higher-load circuits in distribution boards and switchgear.

What residual current sensitivity does it provide?

The ABB F202 A-100/0.1 has a 100 mA rated residual operating current.

What does Type A residual current detection mean?

Type A devices detect alternating residual currents and pulsating DC residual currents, making them suitable for many modern electrical loads.

How is the ABB 2CSF202101R2900 installed?

The device is designed for DIN rail mounting inside electrical distribution boards, control panels and modular switchgear assemblies.

Trusted by Electrical Professionals Worldwide

ABB F200 residual current circuit breakers are widely specified by electricians, panel builders and electrical engineers for dependable earth leakage protection, robust construction and long-term performance in modern electrical installations.