ABB DSE203NMC6A100 3+N 10kA RCBO C6 100mA 2TAZ234414R3064

ABB DSE203NMC6A100 3+N 10kA RCBO C6 100mA 2TAZ234414R3064

SKU: DSE203NMC6A100Alt SKU: DSE203N M C6 A100MPN: 2TAZ234414R3064
Price
List Price £410.63 ex VAT
Your Price (ex VAT) Save 45%
£225.85 45% OFF
You save £184.78 per unit
Manufacturer Lead Time Estimated Delivery 12 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £225.85
Trade pricing is personalised to your account

Manufacturer Lead Time

£225.85

Why Choose the ABB DSE203NMC6A100 RCBO?

The ABB DSE203NMC6A100 is a high-performance 3P+N electronic residual current circuit breaker with overcurrent protection (eRCBO), designed to provide comprehensive protection against overloads, short circuits and earth leakage faults in three-phase electrical installations. Part of the trusted ABB DSE203N M series, this RCBO combines advanced protection and compact installation in a single device for commercial, industrial and OEM applications.

Designed to improve electrical safety and system reliability, the DSE203NMC6A100 protects personnel and equipment by automatically disconnecting the circuit in the event of overload, short circuit or residual current faults. Its electronic residual current sensing delivers dependable protection while simplifying panel layouts by combining multiple protective functions into one device.

With a 6 A Type C trip characteristic, 100 mA Type A residual current sensitivity and a 10 kA breaking capacity, the ABB DSE203NMC6A100 is ideal for protecting three-phase distribution circuits, machinery, control panels and industrial electrical installations. The compact three-module design allows efficient DIN rail installation within modern distribution boards.

Key Advantages

  • Compact 3P+N electronic RCBO combining overcurrent and residual current protection.
  • 6 A Type C characteristic suitable for circuits with moderate inrush currents.
  • 100 mA Type A residual current protection for enhanced electrical safety.
  • 10 kA breaking capacity for demanding commercial and industrial installations.
  • Protects against overloads, short circuits and earth leakage faults.
  • Space-saving three-module design simplifies distribution board layouts.

Key Features

  • ABB DSE203N M electronic RCBO series.
  • Rated current: 6 A.
  • Trip characteristic: Type C.
  • Residual current sensitivity: 100 mA.
  • Residual current type: Type A.
  • Configuration: 3P+N with unswitched neutral.
  • Rated short-circuit breaking capacity: 10 kA.
  • DIN rail mounted for standard distribution boards.

Comprehensive Circuit Protection for Three-Phase Installations

The ABB DSE203NMC6A100 combines miniature circuit breaker and residual current protection into a single compact device. This reduces installation complexity while providing reliable protection against overloads, short circuits and earth leakage faults, helping minimise equipment damage and improve electrical safety.

Its electronic residual current technology and Type C tripping characteristic make it suitable for commercial buildings, industrial machinery, distribution boards and automation systems where dependable protection and high fault-breaking capacity are essential.

Typical Applications

  • Industrial distribution boards.
  • Commercial electrical installations.
  • OEM machinery and equipment.
  • Motor control and automation panels.
  • Manufacturing facilities.
  • Three-phase power distribution systems.

Technical Specifications

Tick the specs you need, then view products that match.

Poles 3-pole + N
Current 6 A
Phase Three Phase
Device Type RCBO
Trip Curve C curve
Residual Current 100 mA
RCD Type Type A
Type 3P+N electronic residual current circuit breaker with overcurrent protection (eRCBO).
Residual Current Type Type A.
Number of Poles Protected 3 poles plus neutral (neutral unswitched).
Operating Characteristic Instantaneous trip function.
Connection Bottom power supply connection; neutral terminal positioned on the left.
Terminal Capacity Busbar 10 mm²; rigid cables 1–25 mm²; flexible cables 1–16 mm².
Electrical Endurance Rated for 10,000 cycles.
Mechanical Endurance Rated for 20,000 cycles.
Weight 0.549 kg.

Frequently Asked Questions

What is the ABB DSE203NMC6A100 used for?

It provides combined overcurrent and residual current protection for three-phase electrical circuits in commercial and industrial installations.

What does the Type C trip characteristic mean?

Type C breakers are designed for circuits with moderate inrush currents, making them suitable for motors, transformers and general industrial loads.

What does the 100 mA residual current rating provide?

The 100 mA residual current sensitivity provides earth leakage protection commonly used for equipment protection and fire prevention applications.

How many poles does this RCBO protect?

The device protects three phases with an unswitched neutral in a 3P+N configuration.

Where is the DSE203NMC6A100 typically installed?

It is installed on standard DIN rails within commercial, industrial and OEM electrical distribution boards and control panels.

Trusted by Electrical Professionals Worldwide

ABB DSE203N M RCBOs are widely specified by electrical contractors, panel builders and industrial engineers for dependable circuit protection, high reliability and compliance with international electrical safety standards.