Why Choose the ABB DSE203NMC50A30 Electronic RCBO?

The ABB DSE203NMC50A30 is a compact three-phase plus neutral electronic residual current circuit breaker with overcurrent protection (eRCBO). It combines overload, short-circuit and earth leakage protection within one device, helping simplify distribution board design while providing dedicated protection for the connected electrical circuit.

Part of the ABB DSE203N M electronic RCBO range, this model is designed for commercial, industrial and building-services installations requiring dependable circuit protection. Its integrated design can reduce wiring complexity, conserve panel space and make fault identification more straightforward than installations using separate overcurrent and residual current devices.

The DSE203NMC50A30 features a rated current of 50 A, a Type C tripping characteristic and 30 mA Type A residual current protection. It is suitable for three-phase circuits supplying equipment with moderate starting currents, including motors, pumps, HVAC systems, commercial machinery and automation equipment.

Key Advantages

  • Combined overload, short-circuit and earth leakage protection.
  • 50 A rated current for higher-load three-phase circuits.
  • 30 mA residual current sensitivity for additional protection against electric shock.
  • Type A residual current detection for AC and pulsating DC fault currents.
  • Type C tripping characteristic for equipment with moderate inrush currents.
  • 10 kA short-circuit breaking capacity.
  • Three-phase plus neutral configuration.
  • Compact electronic RCBO design helps conserve switchboard space.

Key Features

  • ABB DSE203N M electronic RCBO series.
  • 50 A rated current.
  • C-curve overcurrent tripping characteristic.
  • 30 mA rated residual operating current.
  • Type A residual current protection.
  • 10 kA rated breaking capacity.
  • Three protected phases plus neutral connection.
  • Thermal overload protection.
  • Magnetic short-circuit protection.
  • Electronic earth leakage detection.
  • Residual current test function.
  • Earth fault trip and contact position indication.

Combined Protection for Three-Phase Circuits

The ABB DSE203NMC50A30 protects against several common electrical fault conditions. Its thermal mechanism responds to sustained overloads, while magnetic protection provides rapid disconnection during short-circuit events. The electronic residual current system monitors the balance of current flowing through the live conductors and neutral.

When earth leakage reaches the specified operating threshold, the RCBO disconnects the protected circuit. Integrating these protection functions within one device provides individual circuit protection and can prevent a fault on one circuit from unnecessarily interrupting unrelated electrical loads.

Type A Residual Current and C-Curve Protection

Type A residual current protection detects sinusoidal alternating residual currents and pulsating direct residual currents. This makes the DSE203NMC50A30 suitable for circuits containing electronic controls, variable-speed equipment, switch-mode power supplies and other devices that may generate pulsating DC leakage currents.

The Type C tripping characteristic is commonly selected for circuits with moderate starting or inrush currents. Typical applications include motors, pumps, HVAC equipment, transformers, commercial machinery and industrial control systems, subject to the requirements of the electrical installation design.

Typical Applications

  • Commercial distribution boards.
  • Industrial switchboards and control panels.
  • Three-phase motor circuits.
  • HVAC and ventilation equipment.
  • Pumps and compressors.
  • Building-services installations.
  • Automation and machine control systems.
  • General higher-load three-phase final circuits.

Technical Specifications

Tick the specs you need, then view products that match.

Poles 3-pole + N
Current 50 A
Phase Three Phase
Device Type RCBO
Trip Curve C curve
Residual Current 30 mA
RCD Type Type A
Function 3P+N electronic residual current circuit breaker with overcurrent protection (eRCBO).
Number of Poles 3 poles plus neutral (neutral unswitched).
Residual Current Type Type A, 30 mA sensitive for additional direct contact protection.
Operating Characteristic Instantaneous trip for earth fault and overload protection.
Connecting Capacity Suitable for busbars 10 mm², rigid conductors 1–25 mm², and flexible conductors 1–16 mm².
Position of Neutral Terminals Left side.
Electrical Endurance Rated for 10,000 operational cycles.
Mechanical Endurance Rated for 20,000 mechanical cycles.
Weight 0.549 kg.

Frequently Asked Questions

What is the ABB DSE203NMC50A30?

The ABB DSE203NMC50A30 is a 3P+N electronic RCBO that combines overload, short-circuit and Type A residual current protection within one compact device.

What is the rated current of this RCBO?

The DSE203NMC50A30 has a rated current of 50 A.

What tripping characteristic does it use?

This model uses a Type C tripping characteristic, making it suitable for circuits containing equipment with moderate starting currents.

What residual current protection does it provide?

It provides 30 mA Type A residual current protection for sinusoidal AC and pulsating DC earth leakage currents.

What is the short-circuit breaking capacity?

The ABB DSE203NMC50A30 has a rated short-circuit breaking capacity of 10 kA.