ABB DSE203NMC40A100 3+N 10kA RCBO C40 100mA 2TAZ234414R3404

ABB DSE203NMC40A100 3+N 10kA RCBO C40 100mA 2TAZ234414R3404

SKU: DSE203NMC40A100Alt SKU: DSE203N M C40 A100MPN: 2TAZ234414R3404
Price
List Price £410.63 ex VAT
Your Price (ex VAT) Save 45%
£225.85 45% OFF
You save £184.78 per unit
Manufacturer Lead Time Estimated Delivery 12 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £225.85
Trade pricing is personalised to your account

Manufacturer Lead Time

£225.85

Why Choose the ABB DSE203NMC40A100 RCBO?

The ABB DSE203NMC40A100 is a high-performance 3P+N electronic residual current circuit breaker with overcurrent protection (eRCBO), designed to provide reliable protection against overloads, short circuits and earth leakage faults in three-phase electrical installations. As part of the proven ABB DSE203N M series, this compact protective device integrates multiple protection functions into a single unit, making it ideal for commercial, industrial and OEM applications.

Designed to maximise electrical safety and installation efficiency, the DSE203NMC40A100 continuously monitors residual current whilst protecting circuits against overload and short-circuit conditions. By combining overcurrent and residual current protection within one device, it reduces panel space requirements, simplifies installation and improves overall system reliability.

Featuring a 40 A Type C trip characteristic, 100 mA Type A residual current sensitivity and a 10 kA breaking capacity, the ABB DSE203NMC40A100 is ideally suited to protecting three-phase distribution systems, industrial machinery, HVAC equipment, automation systems and commercial electrical installations. Its compact three-module DIN rail mounted construction enables straightforward installation within modern switchboards and control panels.

Key Advantages

  • Compact 3P+N electronic RCBO combining overload, short-circuit and residual current protection.
  • 40 A Type C tripping characteristic for circuits with moderate inrush currents.
  • 100 mA Type A residual current protection.
  • 10 kA breaking capacity for demanding commercial and industrial applications.
  • Protects personnel and electrical equipment against multiple fault conditions.
  • DIN rail mounted design saves valuable space within distribution boards.

Key Features

  • ABB DSE203N M electronic RCBO series.
  • Rated current: 40 A.
  • Trip characteristic: Type C.
  • Residual current sensitivity: 100 mA.
  • Residual current type: Type A.
  • Configuration: 3P+N with unswitched neutral.
  • Rated short-circuit breaking capacity: 10 kA.
  • Compact three-module DIN rail mounted construction.

Reliable Protection for Three-Phase Electrical Systems

The ABB DSE203NMC40A100 combines miniature circuit breaker functionality with advanced electronic residual current protection in a single compact device. This simplifies installation whilst providing dependable protection against overloads, short circuits and earth leakage faults across commercial and industrial electrical systems.

Its Type C tripping characteristic makes it particularly suitable for circuits supplying motors, transformers, HVAC systems, compressors and other equipment with moderate inrush currents. Combined with Type A residual current detection, it delivers reliable protection for modern three-phase installations.

Typical Applications

  • Commercial distribution boards.
  • Industrial electrical installations.
  • Motor control centres.
  • HVAC equipment.
  • OEM machinery.
  • Automation and process control systems.
  • Three-phase power distribution.

Technical Specifications

Tick the specs you need, then view products that match.

Poles 3-pole + N
Current 40 A
Phase Three Phase
Device Type RCBO
Trip Curve C curve
Residual Current 100 mA
RCD Type Type A
Type 3P+N electronic residual current circuit breaker with overcurrent protection (eRCBO).
Residual Current Type Type A.
Number of Poles 3 poles plus neutral (unswitched neutral).
Operating Characteristic Instantaneous.
Rated Current 40 A.
Connection Type Bottom power supply connection.
Terminal Capacity Busbar 10 mm², rigid 1–25 mm², flexible 1–16 mm².
Electrical Endurance 10,000 cycles.
Mechanical Endurance 20,000 cycles.
Position of Neutral Terminal Left side.

Frequently Asked Questions

What is the ABB DSE203NMC40A100 used for?

It provides combined overcurrent and residual current protection for three-phase electrical circuits in commercial, industrial and OEM installations.

What does the Type C trip characteristic mean?

Type C devices are designed for circuits with moderate inrush currents, making them ideal for motors, transformers, compressors and industrial electrical equipment.

What does the 100 mA residual current rating provide?

The 100 mA Type A residual current protection detects AC and pulsating DC earth leakage currents, helping improve electrical safety and equipment protection.

How many poles does this RCBO protect?

The device protects three phases with an unswitched neutral using a 3P+N configuration.

Where is the DSE203NMC40A100 typically installed?

It is designed for DIN rail installation within commercial distribution boards, industrial control panels and OEM electrical equipment.

Trusted by Electrical Professionals Worldwide

ABB DSE203N M RCBOs are trusted by electrical contractors, switchboard manufacturers and industrial engineers for delivering dependable circuit protection, compact installation and compliance with recognised international electrical standards.