Why Choose the ABB DSE203NMC40A10 RCBO?

The ABB DSE203NMC40A10 is a compact 3P+N electronic residual current circuit breaker with overcurrent protection (eRCBO) engineered to protect three-phase electrical installations against overloads, short circuits and earth leakage faults. As part of the ABB DSE203N M series, it combines overcurrent and residual current protection within a single modular device, helping reduce panel space and simplify installation.

Designed for commercial, industrial and OEM applications, the DSE203NMC40A10 features an unswitched neutral, electronic residual current monitoring and DIN rail mounting. It provides dedicated protection for individual three-phase circuits, helping minimise disruption by isolating only the affected circuit when a fault occurs.

With a 40 A rated current, Type C tripping characteristic, 10 mA Type A residual current sensitivity and a 10 kA short-circuit breaking capacity, this RCBO is well suited to protecting circuits supplying equipment with moderate inrush currents while providing enhanced protection against electric shock.

Key Advantages

  • Combined overload, short-circuit and earth leakage protection in one compact device.
  • 40 A rated current for higher-load three-phase circuits.
  • Type C tripping characteristic suitable for moderate inrush current applications.
  • 10 mA Type A residual current protection for enhanced electrical safety.
  • 10 kA short-circuit breaking capacity for dependable fault interruption.
  • Compact three-module DIN rail design saves valuable enclosure space.
  • Suitable for commercial, industrial and machine-building installations.

Key Features

  • ABB DSE203N M electronic RCBO.
  • 3 poles plus neutral (neutral unswitched).
  • 40 A rated current.
  • Type C overcurrent characteristic.
  • 10 mA Type A residual current protection.
  • 10 kA rated short-circuit breaking capacity.
  • Electronic residual current monitoring.
  • DIN rail mounting.

Reliable Protection for Three-Phase Electrical Systems

The ABB DSE203NMC40A10 continuously monitors electrical circuits for overloads, short circuits and earth leakage currents. When a fault is detected, the RCBO disconnects the affected circuit rapidly, helping protect equipment, reduce downtime and improve electrical safety.

Its Type C tripping characteristic is suitable for circuits supplying motors, pumps, lighting systems, transformers and other equipment with moderate starting currents. The integrated 10 mA Type A residual current protection detects both AC and pulsating DC leakage currents, making it suitable for modern installations incorporating electronic equipment.

Typical Applications

  • Commercial electrical distribution boards.
  • Industrial switchboards and control panels.
  • Machine-building and OEM equipment.
  • Three-phase power distribution.
  • Manufacturing and automation systems.
  • Commercial lighting installations.
  • Motor and pump circuits with moderate inrush currents.
  • Critical circuits requiring sensitive 10 mA residual current protection.

Technical Specifications

Tick the specs you need, then view products that match.

Current 40 A
Phase Three Phase
Poles 3-pole + N
Device Type RCBO
Trip Curve C curve
Residual Current 10 mA
RCD Type Type A
Function 3P+N electronic residual current circuit breaker with overcurrent protection (eRCBO).
Current Rating C40 A (40 Amps, Type C characteristic).
Residual Current Type Type A for AC and pulsating DC residual currents.
Number of Poles 3 protected poles + neutral (neutral unswitched).
Connection Type Bottom power supply connection with busbar, rigid (1–25 mm²), and flexible (1–16 mm²) cable compatibility.
Mechanical Endurance 20,000 cycles.
Electrical Endurance 10,000 cycles.
Operating Characteristic Instantaneous tripping for short circuit protection.
Position of Neutral Terminals Left side.

Frequently Asked Questions

What is the ABB DSE203NMC40A10 used for?

The ABB DSE203NMC40A10 provides combined overload, short-circuit and earth leakage protection for three-phase electrical circuits.

What is the rated current of this RCBO?

The DSE203NMC40A10 has a rated current of 40 A.

What does the Type C tripping characteristic mean?

Type C devices are designed for circuits with moderate inrush currents, making them suitable for many commercial and industrial loads including motors and transformers.

What residual current protection does this model provide?

This RCBO provides 10 mA Type A residual current protection capable of detecting both AC and pulsating DC leakage currents.

Where is the ABB DSE203NMC40A10 typically installed?

It is designed for DIN rail installation within commercial and industrial distribution boards, switchboards and electrical control panels.

Trusted Electrical Protection from ABB

ABB DSE203N M electronic RCBOs are trusted by electrical contractors, panel builders and industrial engineers for their compact design, dependable circuit protection and long operational life.