Why Choose the ABB DSE203NMC13A30 RCBO?

The ABB DSE203NMC13A30 is a compact and reliable residual current circuit breaker with overcurrent protection (RCBO) designed for three-phase plus neutral electrical circuits. It combines overload, short-circuit and earth leakage protection within one DIN rail-mounted device, helping improve electrical safety while reducing the number of protective components required inside a distribution board.

As part of the ABB DSE203N RCBO series, this device is suitable for commercial, industrial and advanced residential installations. Its combined protection functions simplify electrical panel design, installation and fault diagnosis by providing both overcurrent and residual current protection for an individual circuit.

The DSE203NMC13A30 has a rated current of 13 A, a Type C tripping characteristic and a rated residual operating current of 30 mA. Its Type A residual current detection provides protection against sinusoidal AC and pulsating DC residual currents, making it suitable for circuits supplying electronic equipment, controls and loads with moderate starting currents.

Key Advantages

  • Combined overload, short-circuit and residual current protection.
  • 13 A rated current for three-phase final circuits and equipment.
  • 30 mA residual current sensitivity for additional protection against electric shock.
  • Type A residual current detection for AC and pulsating DC fault currents.
  • Type C tripping curve suitable for loads with moderate inrush currents.
  • Three-phase plus neutral configuration for four-wire electrical systems.
  • Compact DIN rail design helps conserve distribution board space.
  • Individual circuit protection supports easier fault identification and maintenance.

Key Features

  • ABB DSE203N RCBO series.
  • 13 A rated current.
  • C-curve instantaneous tripping characteristic.
  • 30 mA rated residual operating current.
  • Type A residual current protection.
  • Three protected phases with switched neutral functionality.
  • Thermal protection against sustained overloads.
  • Magnetic protection against short-circuit currents.
  • Integrated earth leakage protection.
  • Test button for routine verification of the residual current mechanism.
  • Modular DIN rail mounting for electrical distribution boards.

Combined Protection for Three-Phase Circuits

An RCBO protects an electrical circuit against several common fault conditions. Its thermal and magnetic protection elements disconnect the supply during sustained overloads or short-circuit events, while the residual current mechanism monitors the balance of current flowing through the live conductors and neutral.

When earth leakage reaches the specified operating threshold, the ABB DSE203NMC13A30 disconnects the protected circuit. Combining these functions within one device provides dedicated residual current protection and can help prevent a fault on one circuit from unnecessarily disconnecting other circuits within the installation.

Type A Residual Current and C-Curve Protection

Type A residual current protection detects sinusoidal alternating residual currents and pulsating direct residual currents. This makes the DSE203NMC13A30 suitable for circuits containing electronic controls, switch-mode power supplies and other modern equipment that may generate pulsating DC leakage currents.

The Type C tripping characteristic allows the RCBO to tolerate moderate starting currents while maintaining effective short-circuit protection. It is commonly selected for circuits supplying small motors, pumps, fans, control transformers, lighting equipment and other commercial or industrial loads.

Typical Applications

  • Three-phase commercial distribution boards.
  • Industrial control and automation circuits.
  • Small motors, pumps and ventilation equipment.
  • Control transformers and inductive electrical loads.
  • Lighting and building services systems.
  • Electronic control equipment and power supplies.
  • Workshops and light industrial installations.
  • Electrical panels requiring individual residual current protection.

Technical Specifications

Tick the specs you need, then view products that match.

Poles 3-pole + N
Current 13 A
Phase Three Phase
Device Type RCBO
Trip Curve C curve
Residual Current 30 mA
RCD Type Type A
Function 3P+N electronic residual current circuit breaker with overcurrent protection (eRCBO).
Residual Current Type Type A, 30 mA for additional direct contact protection.
Poles 3 poles plus neutral (neutral unswitched).
Operating Characteristic Instantaneous tripping.
Connecting Capacity Busbar 10 mm²; rigid conductors 1 to 25 mm²; flexible conductors 1 to 16 mm².
Electrical Endurance 10,000 cycles.
Mechanical Endurance 20,000 cycles.
Position of Neutral Terminals Left side.

Frequently Asked Questions

What is the ABB DSE203NMC13A30 used for?

The ABB DSE203NMC13A30 is used to protect three-phase plus neutral electrical circuits against overloads, short circuits and earth leakage currents.

What is the rated current of this RCBO?

The DSE203NMC13A30 has a rated current of 13 A and a Type C tripping characteristic.

What does the 30 mA rating mean?

The 30 mA value is the rated residual operating current. The RCBO disconnects the protected circuit when earth leakage reaches its operating threshold, providing additional protection against electric shock.

What residual current type does this device use?

This RCBO uses Type A residual current protection, which detects sinusoidal AC and pulsating DC residual fault currents.

What is a Type C tripping characteristic?

A Type C tripping characteristic is suitable for circuits with moderate inrush currents, including small motors, pumps, fans, transformers and commercial electrical equipment.