ABB DSE203NMC13A10 3+N 10kA RCBO C13 10mA 2TAZ234414R1134

ABB DSE203NMC13A10 3+N 10kA RCBO C13 10mA 2TAZ234414R1134

SKU: DSE203NMC13A10Alt SKU: DSE203N M C13 A10MPN: 2TAZ234414R1134
Price
List Price £392.09 ex VAT
Your Price (ex VAT) Save 45%
£215.65 45% OFF
You save £176.44 per unit
Manufacturer Lead Time Estimated Delivery 12 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £215.65
Trade pricing is personalised to your account

Manufacturer Lead Time

£215.65

Why Choose the ABB DSE203NMC13A10 RCBO?

The ABB DSE203NMC13A10 is a compact and dependable electronic residual current circuit breaker with overcurrent protection (eRCBO) designed to protect three-phase electrical circuits against overloads, short circuits and earth leakage faults. Part of the ABB DSE203N M series, it combines residual current and overcurrent protection within a single DIN rail device, helping simplify electrical distribution-board design.

This electronic RCBO is suitable for commercial, industrial and machine-building installations where reliable circuit protection and efficient use of panel space are important. Its 3P+N configuration allows it to protect three-phase circuits incorporating a neutral conductor, while electronic residual current monitoring supports accurate detection of potentially hazardous leakage currents.

With a rated current of 13 A, a Type C tripping characteristic, 10 mA Type A residual current sensitivity and a 10 kA short-circuit breaking capacity, the DSE203NMC13A10 is suitable for circuits supplying equipment with moderate starting currents while providing enhanced protection against electric shock.

Key Advantages

  • Combined residual current and overcurrent protection in one compact device.
  • 13 A rated current for commercial and industrial three-phase circuits.
  • Type C tripping characteristic suitable for loads with moderate inrush currents.
  • 10 mA Type A residual current protection for enhanced electrical safety.
  • 10 kA short-circuit breaking capacity for dependable fault interruption.
  • Space-saving DIN rail design helps simplify distribution-board installation.

Key Features

  • ABB DSE203N M electronic RCBO series.
  • 13 A rated current.
  • Type C overcurrent characteristic.
  • 10 mA Type A residual current protection.
  • 3 poles + neutral configuration.
  • 10 kA rated short-circuit capacity.
  • Electronic residual current detection.
  • DIN rail mounting for electrical distribution boards and control panels.

Reliable Protection for Three-Phase Electrical Circuits

The ABB DSE203NMC13A10 monitors the protected circuit for excessive current and leakage to earth. When an overload, short circuit or residual current fault occurs, the RCBO disconnects the affected circuit to help reduce the risk of equipment damage, electrical fire and electric shock.

Its Type C operating characteristic is suitable for circuits supplying equipment with moderate inrush currents, including selected motors, lighting systems and control equipment. The sensitive 10 mA residual current threshold provides enhanced additional protection where a lower leakage-current trip level is required.

Typical Applications

  • Commercial electrical distribution boards.
  • Industrial control and automation panels.
  • Three-phase lighting and power circuits.
  • Machine building and OEM equipment.
  • Manufacturing and processing facilities.
  • Circuits requiring enhanced residual current protection.

Technical Specifications

Tick the specs you need, then view products that match.

Poles 3-pole + N
Current 13 A
Phase Three Phase
Device Type RCBO
Trip Curve C curve
Residual Current 10 mA
RCD Type Type A
Function 3P+N electronic residual current circuit breaker with overcurrent protection (eRCBO).
Poles 3 poles plus neutral (neutral unswitched).
Residual Current Type Type A with 30 mA version for additional direct contact protection.
Operating Characteristic Instantaneous trip for short-circuit and overload protection.
Connecting Capacity Busbar and terminals accept rigid conductors 1–25 mm² and flexible conductors 1–16 mm².
Electrical Endurance 10,000 cycles; Mechanical Endurance: 20,000 cycles.
Position of Neutral Terminals Left side.

Frequently Asked Questions

What is the ABB DSE203NMC13A10 used for?

The ABB DSE203NMC13A10 protects three-phase electrical circuits against overloads, short circuits and earth leakage faults.

What is the rated current of this RCBO?

The DSE203NMC13A10 has a rated current of 13 A.

What does the Type C characteristic mean?

A Type C tripping characteristic is suitable for circuits with moderate starting currents, including selected motors, lighting systems and control equipment.

What residual current protection does it provide?

This model provides 10 mA Type A residual current protection, detecting sinusoidal AC and pulsating DC leakage currents.

Where is the ABB DSE203NMC13A10 installed?

It is designed for DIN rail installation within commercial or industrial electrical distribution boards and control panels.

Trusted Electrical Protection from ABB

ABB DSE203N M electronic RCBOs are widely specified by electrical contractors, panel builders and industrial engineers for compact installation, dependable fault protection and reliable performance in modern electrical systems.