ABB DSE203NMB6A100 3+N 10kA RCBO B6 100mA 2TAZ234414R3065

ABB DSE203NMB6A100 3+N 10kA RCBO B6 100mA 2TAZ234414R3065

SKU: DSE203NMB6A100Alt SKU: DSE203N M B6 A100MPN: 2TAZ234414R3065
Price
List Price £410.63 ex VAT
Your Price (ex VAT) Save 45%
£225.85 45% OFF
You save £184.78 per unit
Manufacturer Lead Time Estimated Delivery 12 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £225.85
Trade pricing is personalised to your account

Manufacturer Lead Time

£225.85

Why Choose the ABB DSE203NMB6A100 RCBO?

The ABB DSE203NMB6A100 is a premium 3P+N electronic residual current circuit breaker with overcurrent protection (eRCBO), engineered to provide comprehensive protection against overloads, short circuits and earth leakage faults in three-phase electrical systems. As part of the dependable ABB DSE203N M series, this compact device combines multiple protection functions into a single unit, making it ideal for commercial, industrial and OEM applications.

The DSE203NMB6A100 enhances electrical safety by monitoring residual currents while also protecting against overload and short-circuit conditions. Its electronic residual current sensing delivers reliable fault detection, helping safeguard personnel, equipment and installations whilst reducing panel space and simplifying wiring.

Featuring a 6 A Type B trip characteristic, 100 mA Type A residual current sensitivity and a 10 kA breaking capacity, this RCBO is well suited to three-phase distribution boards, industrial machinery, automation systems and commercial electrical installations. Its DIN rail mounting and compact three-module construction make installation quick and efficient.

Key Advantages

  • Compact 3P+N electronic RCBO combining overload, short-circuit and residual current protection.
  • 6 A Type B tripping characteristic for fast protection of sensitive circuits.
  • 100 mA Type A residual current protection.
  • 10 kA breaking capacity for demanding commercial and industrial installations.
  • Protects personnel and equipment against electrical faults.
  • DIN rail mounting for straightforward installation in modern distribution boards.

Key Features

  • ABB DSE203N M electronic RCBO series.
  • Rated current: 6 A.
  • Trip characteristic: Type B.
  • Residual current sensitivity: 100 mA.
  • Residual current type: Type A.
  • Configuration: 3P+N with unswitched neutral.
  • Rated breaking capacity: 10 kA.
  • Compact three-module DIN rail mounted design.

Reliable Protection for Three-Phase Electrical Installations

The ABB DSE203NMB6A100 integrates miniature circuit breaker and residual current protection into a single compact device, reducing installation complexity while delivering dependable protection against overloads, short circuits and earth leakage faults.

Its Type B tripping characteristic makes it suitable for applications requiring rapid disconnection during fault conditions, while the electronic residual current monitoring improves electrical safety and helps maintain reliable operation in industrial and commercial environments.

Typical Applications

  • Commercial distribution boards.
  • Industrial control panels.
  • OEM machinery.
  • Manufacturing facilities.
  • Automation and process control systems.
  • Three-phase electrical installations.

Technical Specifications

Tick the specs you need, then view products that match.

Poles 3-pole + N
Current 6 A
Phase Three Phase
Device Type RCBO
Trip Curve B curve
Residual Current 100 mA
RCD Type Type A
Function 3P+N electronic residual current circuit breaker with overcurrent protection (eRCBO).
Residual Current Type Type A.
Number of Poles 3 poles plus neutral, neutral unswitched.
Operating Characteristic Instantaneous trip.
Connection Type and Size Busbar 10 mm², rigid 1–25 mm², flexible 1–16 mm².
Electrical Endurance 10,000 cycles.
Mechanical Endurance 20,000 cycles.
Position of Neutral Terminals Left side.
Additional Protection Earth fault and indirect contact protection; 30 mA versions include direct contact protection.

Frequently Asked Questions

What is the ABB DSE203NMB6A100 used for?

It provides combined overcurrent and residual current protection for three-phase electrical circuits in industrial, commercial and OEM applications.

What does the Type B trip characteristic mean?

Type B devices provide rapid tripping at lower magnetic fault current levels, making them suitable for protecting sensitive circuits with low inrush currents.

What does the 100 mA residual current rating provide?

The 100 mA Type A residual current protection helps detect earth leakage faults and provides enhanced protection for equipment and installations.

How many poles does this RCBO protect?

The device protects three phases with an unswitched neutral using a 3P+N configuration.

Where is the DSE203NMB6A100 typically installed?

It is designed for DIN rail installation within commercial, industrial and OEM distribution boards and electrical control panels.

Trusted by Electrical Professionals Worldwide

ABB DSE203N M RCBOs are trusted by panel builders, electrical contractors and industrial engineers for delivering dependable circuit protection, compact installation and compliance with recognised international electrical standards.