Why Choose the ABB DSE203NMB13A100 RCBO?

The ABB DSE203NMB13A100 is a high-performance 3P+N electronic residual current circuit breaker with overcurrent protection (eRCBO), designed to provide reliable protection against overloads, short circuits and earth leakage faults in three-phase electrical installations. As part of the proven ABB DSE203N M series, this compact device integrates multiple protection functions into a single unit, making it an excellent choice for commercial, industrial and OEM applications.

Designed to improve electrical safety and system reliability, the DSE203NMB13A100 continuously monitors residual current whilst protecting circuits against overload and short-circuit conditions. Its electronic residual current technology helps safeguard personnel and equipment whilst reducing installation space within distribution boards and control panels.

With a 13 A Type B trip characteristic, 100 mA Type A residual current sensitivity and a 10 kA breaking capacity, the ABB DSE203NMB13A100 is ideal for protecting three-phase distribution systems, industrial machinery, automation equipment and commercial electrical installations. Its compact DIN rail mounted design enables straightforward installation within modern switchboards.

Key Advantages

  • Compact 3P+N electronic RCBO combining overload, short-circuit and residual current protection.
  • 13 A Type B tripping characteristic for rapid protection of sensitive circuits.
  • 100 mA Type A residual current protection.
  • 10 kA breaking capacity suitable for demanding commercial and industrial installations.
  • Protects personnel and electrical equipment against multiple fault conditions.
  • DIN rail mounted design saves valuable distribution board space.

Key Features

  • ABB DSE203N M electronic RCBO series.
  • Rated current: 13 A.
  • Trip characteristic: Type B.
  • Residual current sensitivity: 100 mA.
  • Residual current type: Type A.
  • Configuration: 3P+N with unswitched neutral.
  • Rated short-circuit breaking capacity: 10 kA.
  • Compact three-module DIN rail mounted construction.

Reliable Circuit Protection for Three-Phase Installations

The ABB DSE203NMB13A100 combines miniature circuit breaker functionality with electronic residual current protection within a single compact device. This simplifies installation whilst delivering dependable protection against overloads, short circuits and earth leakage faults across commercial and industrial electrical systems.

Its Type B tripping characteristic provides rapid operation for circuits with relatively low inrush currents, making it well suited for protecting sensitive electrical equipment, automation systems and distribution circuits requiring dependable fault protection.

Typical Applications

  • Commercial distribution boards.
  • Industrial electrical installations.
  • OEM machinery.
  • Automation and process control systems.
  • Manufacturing facilities.
  • Three-phase power distribution.

Technical Specifications

Tick the specs you need, then view products that match.

Poles 3-pole + N
Current 13 A
Phase Three Phase
Device Type RCBO
Trip Curve B curve
Residual Current 100 mA
RCD Type Type A
Function 3P+N electronic residual current circuit breaker with overcurrent protection (eRCBO).
Residual Current Type Type A.
Number of Poles 3 poles plus neutral (neutral unswitched).
Connection Bottom power supply connection.
Terminal Capacity Busbar 10 mm², rigid 1–25 mm², flexible 1–16 mm².
Operating Characteristic Instantaneous.
Electrical Endurance 10,000 cycles.
Mechanical Endurance 20,000 cycles.
Position of Neutral Terminals Left.

Frequently Asked Questions

What is the ABB DSE203NMB13A100 used for?

It provides combined overcurrent and residual current protection for three-phase electrical circuits in industrial, commercial and OEM installations.

What does the Type B trip characteristic mean?

Type B devices provide rapid magnetic tripping at relatively low fault current levels, making them suitable for protecting circuits with low inrush currents.

What does the 100 mA residual current rating provide?

The 100 mA Type A residual current protection detects earth leakage faults and helps improve electrical safety whilst protecting equipment and electrical installations.

How many poles does this RCBO protect?

The device protects three phases with an unswitched neutral using a 3P+N configuration.

Where is the DSE203NMB13A100 typically installed?

It is designed for DIN rail installation within commercial distribution boards, industrial control panels and OEM electrical equipment.

Trusted by Electrical Professionals Worldwide

ABB DSE203N M RCBOs are trusted by electrical contractors, panel builders and industrial engineers for delivering reliable circuit protection, compact installation and compliance with recognised international electrical standards.