2CSR772440R3325 ABB DS202CR M B32 APR300 RCBO 32 A 300 mA 2P

2CSR772440R3325 ABB DS202CR M B32 APR300 RCBO 32 A 300 mA 2P

ABB DS202CR M B32 APR300 two-pole Type A AP-R RCBO with 32 A rated current, 300 mA residual current sensitivity, B tripping characteristic, 10 kA breaking capacity and enhanced resistance to unwanted tripping for residential, commercial and industrial single-phase circuits.

SKU: 2CSR772440R3325Alt SKU: DS202CRMB32APR300MPN: 2CSR772440R3325
Price
List Price £315.71 ex VAT
Your Price (ex VAT) Save 35%
£205.21 35% OFF
You save £110.50 per unit
Manufacturer Lead Time Estimated Delivery 9 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £205.21
Trade pricing is personalised to your account

Manufacturer Lead Time

£205.21

Why Choose the ABB DS202CR M B32 APR300 RCBO?

The ABB DS202CR M B32 APR300 is a compact two-pole residual current circuit breaker with overcurrent protection (RCBO) designed to protect single-phase circuits against overloads, short circuits and residual earth fault currents. As part of the ABB DS202CR range within the DS200 / DSH200 RCBO product group, it combines overcurrent and residual current protection within a space-efficient two-module DIN-rail device.

This RCBO features Type A AP-R residual current protection, providing protection against sinusoidal alternating and pulsating direct residual currents while offering increased immunity to unwanted tripping. ABB AP-R technology is designed to provide an effective balance between electrical protection and continuity of service, particularly in installations where transient disturbances could otherwise cause unnecessary operation of residual current protection.

With a rated current of 32 A, a rated residual operating current of 300 mA, a B tripping characteristic and a 10 kA rated short-circuit breaking capacity, the DS202CR M B32 APR300 provides dependable protection for residential, commercial and industrial circuits. Its 3,000 A resistance to unwanted tripping with an 8/20 µs surge waveform further supports continuity of service in electrically demanding installations.

Key Advantages

  • Combined residual current, overload and short-circuit protection in one compact device.
  • 32 A rated current with B-curve tripping characteristic.
  • 300 mA Type A AP-R residual current protection.
  • Enhanced immunity to transient disturbances helps reduce unwanted tripping.
  • 3,000 A resistance to unwanted tripping with an 8/20 µs surge waveform.
  • 10 kA rated short-circuit breaking capacity for robust circuit protection.
  • Two-pole construction for single-phase circuit protection.
  • Compact two-module DIN-rail format saves distribution board space.

Key Features

  • ABB DS202CR M AP-R RCBO series.
  • 32 A rated current.
  • 300 mA rated residual operating current.
  • Type A AP-R residual current characteristic.
  • B tripping characteristic.
  • Two-pole configuration.
  • 10 kA rated short-circuit breaking capacity.
  • 3,000 A resistance to unwanted tripping with an 8/20 µs surge waveform.
  • Protection against overload and short-circuit currents.
  • Protection against sinusoidal alternating and pulsating direct residual currents.
  • Designed for residential, commercial and industrial applications.
  • Compact two-module construction for DIN-rail installation.

Reliable Circuit Protection with AP-R Technology

RCBOs combine the functions of a miniature circuit breaker and residual current protection device within a single unit. The ABB DS202CR M B32 APR300 therefore protects single-phase circuits against excessive current caused by overloads and short circuits while simultaneously detecting sinusoidal alternating and pulsating direct residual earth fault currents.

The Type A AP-R characteristic provides increased immunity to unwanted tripping, with resistance of 3,000 A to an 8/20 µs surge waveform. Combined with its 300 mA residual current sensitivity, B-curve characteristic and 10 kA breaking capacity, the DS202CR M B32 APR300 provides reliable earth fault and overcurrent protection where continuity of service is an important requirement.

Typical Applications

  • Residential electrical distribution systems.
  • Commercial buildings and electrical installations.
  • Industrial electrical distribution panels.
  • Higher-current single-phase final circuits.
  • Power and auxiliary electrical circuits.
  • Circuits with relatively low starting and inrush currents.
  • Installations requiring 300 mA residual current protection.
  • Circuits requiring enhanced immunity to unwanted residual current tripping.

Technical Specifications

Series DS202CR
Product group DS200 / DSH200 RCBO
Manufacturer material ID DS202CRMB32APR300
ABB order code 2CSR772440R3325
EAN 4022903035411
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 2
Rated current 32 A
Rated residual current 300 mA
Residual current type Type A AP-R
Tripping characteristic B
Rated short-circuit breaking capacity (Icn) 10 kA
Resistance to unwanted tripping 3,000 A (8/20 µs waveform)
Mounting type DIN rail
Module width 2 modules
Standards IEC/EN 61009-1; IEC/EN 61009-2-1
Applications Residential, commercial and industrial electrical installations
Weight approx. 0.245 kg

Frequently Asked Questions

What is the ABB DS202CR M B32 APR300 used for?

The ABB DS202CR M B32 APR300 provides combined protection against overloads, short circuits and residual earth fault currents in residential, commercial and industrial single-phase electrical circuits.

What is the rated current of the DS202CR M B32 APR300?

The RCBO has a rated current of 32 A and uses a B tripping characteristic, making it suitable for circuits with relatively low starting and inrush currents.

What does AP-R mean on the ABB DS202CR M B32 APR300?

AP-R identifies ABB residual current protection designed with increased immunity to unwanted tripping. The DS202CR M B32 APR300 provides resistance of 3,000 A to an 8/20 µs surge waveform, helping improve continuity of service during transient disturbances.

What residual current sensitivity does this RCBO provide?

The DS202CR M B32 APR300 has a rated residual operating current of 300 mA and provides Type A AP-R protection against sinusoidal alternating and pulsating direct residual currents.

What is the breaking capacity of the ABB DS202CR M B32 APR300?

The DS202CR M B32 APR300 has a rated short-circuit breaking capacity of 10 kA in accordance with IEC/EN 61009-1 and IEC/EN 61009-2-1.