2CSR772440R3135 ABB DS202CR M B13 APR300 RCBO 13 A 300 mA 2P

2CSR772440R3135 ABB DS202CR M B13 APR300 RCBO 13 A 300 mA 2P

ABB DS202CR M B13 APR300 two-pole Type A AP-R RCBO with 13 A rated current, 300 mA residual current sensitivity, B tripping characteristic, 10 kA breaking capacity and enhanced resistance to unwanted tripping for residential, commercial and industrial single-phase circuits.

SKU: 2CSR772440R3135Alt SKU: DS202CRMB13APR300MPN: 2CSR772440R3135
Price
List Price £315.71 ex VAT
Your Price (ex VAT) Save 35%
£205.21 35% OFF
You save £110.50 per unit
Manufacturer Lead Time Estimated Delivery 9 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £205.21
Trade pricing is personalised to your account

Manufacturer Lead Time

£205.21

Why Choose the ABB DS202CR M B13 APR300 RCBO?

The ABB DS202CR M B13 APR300 is a compact two-pole residual current circuit breaker with overcurrent protection (RCBO) designed to protect single-phase circuits against overloads, short circuits and residual earth fault currents. As part of the ABB DS202CR range within the DS200 / DSH200 RCBO product group, it combines overcurrent and residual current protection in a space-efficient two-module DIN-rail device.

This RCBO features Type A AP-R residual current protection, providing protection against sinusoidal alternating and pulsating direct residual currents while offering increased immunity to unwanted tripping. ABB AP-R technology provides a balance between electrical protection and continuity of service, making it particularly useful in installations where transient disturbances could otherwise cause unnecessary operation of residual current protection.

With a rated current of 13 A, a rated residual operating current of 300 mA, a B tripping characteristic and a 10 kA rated short-circuit breaking capacity, the DS202CR M B13 APR300 provides dependable protection for residential, commercial and industrial circuits. Its 3,000 A resistance to unwanted tripping with an 8/20 µs surge waveform further supports continuity of service in electrically demanding installations.

Key Advantages

  • Combined residual current, overload and short-circuit protection in one compact device.
  • 13 A rated current with B-curve tripping characteristic.
  • 300 mA Type A AP-R residual current protection.
  • Enhanced immunity to transient disturbances helps reduce unwanted tripping.
  • 3,000 A resistance to unwanted tripping with an 8/20 µs surge waveform.
  • 10 kA rated short-circuit breaking capacity for robust circuit protection.
  • Two protected poles for comprehensive single-phase circuit protection.
  • Compact two-module DIN-rail format saves distribution board space.

Key Features

  • ABB DS202CR M AP-R RCBO series.
  • 13 A rated current.
  • 300 mA rated residual operating current.
  • Type A AP-R residual current characteristic.
  • B tripping characteristic.
  • Two-pole configuration.
  • 10 kA rated short-circuit breaking capacity.
  • 3,000 A resistance to unwanted tripping with an 8/20 µs surge waveform.
  • Protection against overload and short-circuit currents.
  • Protection against sinusoidal alternating and pulsating direct residual currents.
  • Integrated test function for verification of residual current operation.
  • DIN-rail mounting in a compact two-module enclosure.

Reliable Circuit Protection with AP-R Technology

RCBOs combine the functions of a miniature circuit breaker and residual current protection device within a single unit. The ABB DS202CR M B13 APR300 therefore protects single-phase circuits against excessive current caused by overloads and short circuits while simultaneously detecting sinusoidal alternating and pulsating direct residual earth fault currents.

The Type A AP-R characteristic provides increased immunity to unwanted tripping, with resistance of 3,000 A to an 8/20 µs surge waveform. Combined with its 300 mA residual current sensitivity, B-curve characteristic and 10 kA breaking capacity, the DS202CR M B13 APR300 provides reliable earth fault and overcurrent protection where continuity of service is an important requirement.

Typical Applications

  • Residential electrical distribution systems.
  • Commercial buildings and electrical installations.
  • Industrial electrical distribution panels.
  • Single-phase final circuits.
  • Lighting and auxiliary electrical circuits.
  • Circuits with relatively low starting and inrush currents.
  • Installations requiring 300 mA residual current protection.
  • Circuits requiring enhanced immunity to unwanted residual current tripping.

Technical Specifications

Series DS202CR
Product group DS200 / DSH200 RCBO
Manufacturer material ID DS202CRMB13APR300
ABB order code 2CSR772440R3135
EAN 4022903035374
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 2
Rated current 13 A
Rated residual current 300 mA
Residual current type Type A AP-R
Tripping characteristic B
Rated short-circuit breaking capacity (Icn) 10 kA
Resistance to unwanted tripping 3,000 A (8/20 µs waveform)
Mounting type DIN rail
Module width 2 modules
Standards IEC/EN 61009-1; IEC/EN 61009-2-1
Applications Residential, commercial and industrial electrical installations
Weight approx. 0.245 kg

Frequently Asked Questions

What is the ABB DS202CR M B13 APR300 used for?

The ABB DS202CR M B13 APR300 provides combined protection against overloads, short circuits and residual earth fault currents in residential, commercial and industrial single-phase electrical circuits.

What is the rated current of the DS202CR M B13 APR300?

The RCBO has a rated current of 13 A and uses a B tripping characteristic, making it suitable for circuits with relatively low starting and inrush currents.

What does AP-R mean on the ABB DS202CR M B13 APR300?

AP-R identifies ABB residual current protection designed with increased immunity to unwanted tripping. The DS202CR M B13 APR300 provides resistance of 3,000 A to an 8/20 µs surge waveform, helping improve continuity of service during transient disturbances.

What residual current sensitivity does this RCBO provide?

The DS202CR M B13 APR300 has a rated residual operating current of 300 mA and provides Type A AP-R protection against sinusoidal alternating and pulsating direct residual currents.

What is the breaking capacity of the ABB DS202CR M B13 APR300?

The DS202CR M B13 APR300 has a rated short-circuit breaking capacity of 10 kA in accordance with the applicable IEC/EN 61009 standards.

Trusted ABB Circuit Protection

ABB DS202CR M AP-R RCBOs combine overcurrent and residual current protection with increased immunity to unwanted tripping, providing dependable circuit protection and continuity of service for residential, commercial and industrial electrical installations.