2CSR772440R1325 ABB DS202CRMB32APR30 RCBO 2P APR Type A B32 30 mA 10 kA

2CSR772440R1325 ABB DS202CRMB32APR30 RCBO 2P APR Type A B32 30 mA 10 kA

ABB DS202CRMB32APR30 is a 2-pole APR Type A RCBO with a 32 A B-curve rating, 30 mA residual current sensitivity and 10 kA breaking capacity, offering increased resistance to unwanted tripping.

SKU: 2CSR772440R1325Alt SKU: DS202CRMB32APR30MPN: 2CSR772440R1325
Price
List Price £299.17 ex VAT
Your Price (ex VAT) Save 35%
£194.46 35% OFF
You save £104.71 per unit
Manufacturer Lead Time Estimated Delivery 9 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £194.46
Trade pricing is personalised to your account

Manufacturer Lead Time

£194.46

Why Choose the ABB DS202CRMB32APR30 RCBO?

The ABB DS202CRMB32APR30 is a compact 2-pole residual current circuit breaker with overcurrent protection (RCBO) designed to protect end-user single-phase circuits against overloads, short circuits and residual earth fault currents. Part of the ABB DS202CR M APR series, it combines overcurrent and residual current protection within a space-saving two-module device for residential, commercial and industrial electrical installations.

This RCBO features ABB's APR Type A residual current characteristic, providing protection against the effects of sinusoidal alternating and direct pulsating earth fault currents while offering increased resistance to unwanted tripping. Its Type B overcurrent tripping characteristic is suited to general circuits with relatively low inrush currents, while its 30 mA residual current sensitivity provides protection against indirect contact and additional protection against direct contact.

With a rated current of 32 A, rated residual operating current of 30 mA, rated voltage of 230 V and rated short-circuit breaking capacity of 10 kA, the DS202CRMB32APR30 delivers dependable combined protection in a compact DIN-rail format. ABB order code 2CSR772440R1325 identifies the DS202CR M B32 APR30 configuration.

Key Advantages

  • Combined overload, short-circuit and residual current protection in one device.
  • 32 A rated current with Type B overcurrent tripping characteristic.
  • 30 mA residual current sensitivity for additional protection against direct contact.
  • APR characteristic provides increased resistance to unwanted residual-current tripping.
  • Type A protection against sinusoidal AC and direct pulsating earth fault currents.
  • 10 kA rated short-circuit breaking capacity for robust fault protection.
  • 3 kA resistance to unwanted tripping with an 8/20 µs surge wave.
  • Compact 2-pole protection in two modules helps conserve distribution-board space.

Key Features

  • ABB DS202CR M APR series RCBO.
  • 2-pole configuration in a two-module format.
  • 32 A rated current.
  • 30 mA rated residual operating current.
  • APR Type A residual current characteristic.
  • Type B overcurrent tripping characteristic.
  • 230 V rated voltage.
  • 50 Hz rated frequency.
  • 10 kA rated short-circuit breaking capacity.
  • IP20 protection rating.
  • DIN-rail mounting for modular electrical distribution equipment.

Reliable Protection with Enhanced Continuity of Service

The ABB DS202CRMB32APR30 combines miniature circuit breaker and residual current protection functions within a single compact device. It disconnects the protected circuit during overload or short-circuit conditions while also detecting sinusoidal alternating and direct pulsating earth fault currents, providing comprehensive protection without requiring separate MCB and residual current devices.

ABB's APR characteristic is designed to provide an effective balance between electrical safety and continuity of service through increased resistance to unwanted tripping caused by transient disturbances. With resistance to unwanted tripping of 3 kA on an 8/20 µs surge wave, the DS202CRMB32APR30 is particularly useful where improved continuity is required while retaining sensitive 30 mA residual current protection.

Typical Applications

  • Residential electrical distribution boards.
  • Commercial building electrical installations.
  • Industrial electrical distribution systems.
  • Single-phase end-user circuits requiring combined protection.
  • Circuits requiring 30 mA Type A residual current protection.
  • Installations where improved resistance to unwanted tripping is desirable.
  • General-purpose circuits suited to a Type B tripping characteristic.
  • DIN-rail mounted modular distribution equipment.

Technical Specifications

Series DS202CR M APR
Manufacturer type code DS202CR M B32 APR30
ABB order code 2CSR772440R1325
EAN 4022903035329
Product group DS200 / DSH200 RCBO
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 2
Rated current 32 A
Tripping characteristic B
Residual current characteristic APR Type A
Rated residual operating current 30 mA
Rated voltage 230 V
Rated frequency 50 Hz
Rated short-circuit breaking capacity (Icn) 10 kA
Rated ultimate short-circuit breaking capacity (Icu) 10 kA
Resistance to unwanted tripping (8/20 µs wave) 3 kA
Protection rating IP20
Reference standards IEC/EN 61009-1; IEC/EN 61009-2-1
Mounting type DIN rail
Module width 2 modules
Dimensions (W × H × D) 36 × 86 × 72 mm
Weight approx. 0.245 kg

Frequently Asked Questions

What is the ABB DS202CRMB32APR30 used for?

The DS202CRMB32APR30 provides combined protection against overloads, short circuits and residual earth fault currents in end-user single-phase circuits, with an APR characteristic designed to increase resistance to unwanted tripping.

What is the rated current of the DS202CRMB32APR30?

The ABB DS202CRMB32APR30 has a rated current of 32 A and uses a Type B overcurrent tripping characteristic.

What does APR mean on the ABB DS202CRMB32APR30?

The APR characteristic provides increased resistance to unwanted residual-current tripping, helping balance electrical safety and continuity of service while retaining Type A protection against sinusoidal AC and direct pulsating earth fault currents.

What residual current sensitivity does the DS202CRMB32APR30 provide?

The DS202CRMB32APR30 has a rated residual operating current of 30 mA, providing protection against indirect contact and additional protection against direct contact.

What is the breaking capacity of the ABB DS202CRMB32APR30?

The DS202CRMB32APR30 has a rated short-circuit breaking capacity of 10 kA.

Trusted ABB Protection with Enhanced Service Continuity

ABB DS202CR M APR RCBOs combine residual current and overcurrent protection with enhanced resistance to unwanted tripping, providing dependable protection and improved continuity of service for residential, commercial and industrial electrical installations.