2CSR772198R1405 ABB DS202CRMB405060HZ DS202CR M B40 Type A 30 mA 50/60 Hz RCBO 2P

2CSR772198R1405 ABB DS202CRMB405060HZ DS202CR M B40 Type A 30 mA 50/60 Hz RCBO 2P

ABB DS202CRMB405060HZ is a compact 2-pole Type A marine RCBO with a 40 A rated current, B tripping characteristic, 30 mA residual-current sensitivity, 50/60 Hz dual-frequency compatibility and 10 kA short-circuit capacity.

SKU: 2CSR772198R1405Alt SKU: DS202CRMB405060HZMPN: 2CSR772198R1405
Price
List Price £257.08 ex VAT
Your Price (ex VAT) Save 35%
£167.10 35% OFF
You save £89.98 per unit
Manufacturer Lead Time Estimated Delivery 9 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £167.10
Trade pricing is personalised to your account

Manufacturer Lead Time

£167.10

Why Choose the ABB DS202CRMB405060HZ RCBO?

The ABB DS202CRMB405060HZ is a compact and reliable 2-pole residual current circuit breaker with overcurrent protection (RCBO) designed for marine electrical installations requiring dual-frequency operation. As part of the ABB DS202CR M 50/60 Hz series, it combines overload, short-circuit and residual-current protection in a space-saving two-module device for end-user circuits.

This RCBO provides a 40 A rated current, B tripping characteristic and Type A residual-current protection. Type A protection detects sinusoidal alternating residual currents and direct pulsating residual currents, making the device suitable for circuits supplying a broad range of modern electrical and electronic equipment.

With a rated residual operating current of 30 mA, 50/60 Hz dual-frequency compatibility and a rated short-circuit capacity of 10 kA, the DS202CRMB405060HZ provides comprehensive protection for suitable marine circuits. Its compact 2-pole, two-module format helps conserve valuable DIN-rail space while providing dependable overcurrent and earth-fault protection.

Key Advantages

  • Combined RCBO protection against overload, short circuit and residual-current faults.
  • 40 A rated current for higher-current final circuits.
  • B tripping characteristic suitable for circuits with relatively low inrush currents.
  • Type A residual-current protection for sinusoidal AC and pulsating DC residual currents.
  • 30 mA rated residual operating current for additional protection against direct contact.
  • 50/60 Hz dual-frequency compatibility for marine electrical systems.
  • 10 kA rated short-circuit capacity for robust circuit protection.
  • Compact 2-pole design occupying two modules to optimise DIN-rail space.

Key Features

  • ABB DS202CR M 50/60 Hz series RCBO.
  • 40 A rated current.
  • B tripping characteristic.
  • Type A residual-current characteristic.
  • 30 mA residual-current sensitivity.
  • 2-pole configuration.
  • 10 kA rated short-circuit capacity.
  • 50/60 Hz dual-frequency operation.
  • Compact two-module DIN-rail format.
  • Designed specifically for marine electrical applications.
  • Test pushbutton for functional verification.
  • Earth-fault indicator for easier fault identification.
  • Contact position indicator (CPI) for clear contact-status indication.

Dual-Frequency Protection for Marine Electrical Systems

RCBOs combine the functions of a miniature circuit breaker and a residual-current device in one protective unit. The ABB DS202CRMB405060HZ protects end-user circuits against excessive current caused by overloads and short circuits while also detecting sinusoidal alternating and direct pulsating earth-fault currents.

The DS202CR M 50/60 Hz range is designed for marine applications where compatibility with both 50 Hz and 60 Hz electrical systems is required. Its Type A residual-current characteristic, 30 mA sensitivity and compact two-pole construction provide effective circuit protection while making efficient use of distribution-board space.

Typical Applications

  • Marine electrical distribution systems.
  • Shipboard final circuit protection.
  • Marine control and distribution panels.
  • Circuits operating at 50 Hz or 60 Hz.
  • Circuits supplying electrical and electronic equipment.
  • Marine auxiliary and service circuits.
  • Installations requiring compact combined overcurrent and residual-current protection.

Technical Specifications

Series DS202CR M 50/60 Hz
Type code DS202CR M B40 A30 50/60
ABB order code 2CSR772198R1405
EAN 4022903035053
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 2
Rated current 40 A
Tripping characteristic B
Residual-current type Type A
Rated residual operating current 30 mA
Rated frequency 50/60 Hz
Rated short-circuit capacity (Icn) 10 kA
Module width 2 modules
Mounting type DIN rail
Weight approx. 0.245 kg
Application Marine electrical installations
Standards IEC/EN 61009-1; IEC/EN 61009-2-1

Frequently Asked Questions

What is the ABB DS202CRMB405060HZ used for?

The DS202CRMB405060HZ is a 2-pole RCBO designed for marine electrical applications, protecting end-user circuits against overloads, short circuits and residual earth-fault currents.

What is the rated current of the ABB DS202CRMB405060HZ?

The RCBO has a rated current of 40 A and uses a B tripping characteristic.

What residual-current sensitivity does this RCBO provide?

The DS202CRMB405060HZ has a rated residual operating current of 30 mA and provides Type A residual-current protection.

Can the DS202CRMB405060HZ operate at both 50 Hz and 60 Hz?

Yes. This ABB DS202CR M variant provides 50/60 Hz dual-frequency compatibility for marine electrical applications.

What is the breaking capacity of the DS202CRMB405060HZ?

The ABB DS202CRMB405060HZ has a rated short-circuit capacity of 10 kA, providing robust overcurrent protection for suitable marine circuits.

Trusted Marine Circuit Protection from ABB

ABB DS202CR M 50/60 Hz RCBOs provide compact combined overcurrent and residual-current protection for marine electrical installations, combining dual-frequency compatibility with dependable protection in a space-saving two-module format.