2CSR772198R1325 ABB DS202CRMB325060HZ RCBO 2P Type A B32 30 mA 50/60 Hz 10 kA

2CSR772198R1325 ABB DS202CRMB325060HZ RCBO 2P Type A B32 30 mA 50/60 Hz 10 kA

ABB DS202CRMB325060HZ is a 2-pole Type A marine RCBO with a 32 A B-curve rating, 30 mA residual current sensitivity, 50/60 Hz dual-frequency compatibility and 10 kA breaking capacity.

SKU: 2CSR772198R1325Alt SKU: DS202CRMB325060HZMPN: 2CSR772198R1325
Price
List Price £257.08 ex VAT
Your Price (ex VAT) Save 35%
£167.10 35% OFF
You save £89.98 per unit
Manufacturer Lead Time Estimated Delivery 9 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £167.10
Trade pricing is personalised to your account

Manufacturer Lead Time

£167.10

Why Choose the ABB DS202CRMB325060HZ RCBO?

The ABB DS202CRMB325060HZ is a compact and reliable 2-pole residual current circuit breaker with overcurrent protection (RCBO) designed for marine electrical applications requiring dependable operation at both 50 and 60 Hz. Part of the ABB DS202CR M 50/60 series, it combines protection against overloads, short circuits and residual earth fault currents within a space-saving two-module device.

This RCBO features Type A residual current detection for sinusoidal alternating and pulsating DC earth fault currents, together with a Type B tripping characteristic for overcurrent protection. Its 30 mA residual current sensitivity provides protection against indirect contact and additional protection against direct contact, while its dual-frequency design makes it particularly suitable for shipboard and marine electrical distribution systems.

With a rated current of 32 A, a rated residual operating current of 30 mA, 50/60 Hz dual-frequency compatibility and a rated short-circuit breaking capacity of 10 kA, the DS202CRMB325060HZ provides comprehensive circuit protection in a compact DIN-rail format. ABB order code 2CSR772198R1325 identifies the manufacturer type code DS202CR M B32 A30 50/60.

Key Advantages

  • Combined overload, short-circuit and residual current protection in one device.
  • 50/60 Hz dual-frequency compatibility for marine electrical systems.
  • 32 A rated current with Type B tripping characteristic.
  • 30 mA residual current sensitivity for additional protection against direct contact.
  • Type A residual current detection for sinusoidal AC and pulsating DC earth fault currents.
  • 10 kA rated short-circuit breaking capacity for robust fault protection.
  • Compact 2-pole protection in only two modules helps conserve valuable distribution-board space.
  • Designed specifically for dependable circuit protection in marine electrical installations.

Key Features

  • ABB DS202CR M 50/60 series RCBO.
  • 2-pole configuration in a two-module format.
  • 32 A rated current.
  • 30 mA rated residual operating current.
  • Type A residual current characteristic.
  • Type B overcurrent tripping characteristic.
  • 50/60 Hz dual-frequency operation.
  • 10 kA rated short-circuit breaking capacity.
  • Designed for marine electrical applications.
  • DIN-rail mounting for compact modular distribution systems.

Reliable Circuit Protection for Marine Electrical Systems

RCBOs such as the ABB DS202CRMB325060HZ combine miniature circuit breaker and residual current protection functions within a single compact device. The RCBO disconnects the protected circuit in response to overloads and short circuits while also detecting sinusoidal alternating and pulsating DC earth fault currents, helping protect electrical installations and people against electrical hazards.

The DS202CR M 50/60 range is specifically designed for marine applications where compatibility with both 50 and 60 Hz electrical systems is required. Its compact two-module construction helps conserve valuable panel space, while the 30 mA Type A residual current function provides additional protection against direct contact in appropriate installations.

Typical Applications

  • Marine electrical distribution boards.
  • Shipboard single-phase electrical circuits.
  • Marine auxiliary electrical systems.
  • On-board control and distribution panels.
  • Circuits requiring 50/60 Hz dual-frequency compatibility.
  • Marine circuits requiring 30 mA Type A residual current protection.
  • 32 A branch and final circuits requiring combined protection.
  • Compact DIN-rail mounted marine distribution equipment.

Technical Specifications

Series DS202CR M 50/60
Manufacturer type code DS202CR M B32 A30 50/60
ABB order code 2CSR772198R1325
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Application Marine
Number of poles 2
Rated current 32 A
Tripping characteristic B
Residual current type Type A
Rated residual operating current 30 mA
Rated frequency 50/60 Hz
Rated short-circuit breaking capacity (Icn) 10 kA
Reference standards IEC/EN 61009-1; IEC/EN 61009-2-1
Mounting type DIN rail
Module width 2 modules
Weight approx. 0.245 kg

Frequently Asked Questions

What is the ABB DS202CRMB325060HZ used for?

The DS202CRMB325060HZ is designed for marine electrical applications, providing combined protection against overloads, short circuits and residual earth fault currents.

What is the rated current of the DS202CRMB325060HZ?

The ABB DS202CRMB325060HZ has a rated current of 32 A and uses a Type B tripping characteristic.

What residual current sensitivity does this RCBO provide?

The DS202CRMB325060HZ has a rated residual operating current of 30 mA and uses Type A residual current detection for sinusoidal AC and pulsating DC earth fault currents.

Can the ABB DS202CRMB325060HZ operate at both 50 and 60 Hz?

Yes. This DS202CR M variant is designed for 50/60 Hz dual-frequency operation, making it suitable for marine electrical systems operating at either frequency.

What is the breaking capacity of the ABB DS202CRMB325060HZ?

The DS202CRMB325060HZ has a rated short-circuit breaking capacity of 10 kA.

Trusted ABB Protection for Marine Electrical Systems

ABB DS202CR M 50/60 RCBOs combine dual-frequency compatibility, residual current protection and overcurrent protection in a compact two-module format designed for dependable marine electrical distribution.