2CSR772198R1205 ABB DS202CR M B20 A30 50/60 RCBO 20 A 30 mA 2P

2CSR772198R1205 ABB DS202CR M B20 A30 50/60 RCBO 20 A 30 mA 2P

ABB DS202CR M B20 A30 50/60 two-pole Type A RCBO with 20 A rated current, 30 mA residual current sensitivity, B tripping characteristic and 10 kA breaking capacity for 230 V AC 50/60 Hz electrical circuits.

SKU: 2CSR772198R1205Alt SKU: DS202CRMB205060HZMPN: 2CSR772198R1205
Price
List Price £257.08 ex VAT
Your Price (ex VAT) Save 35%
£167.10 35% OFF
You save £89.98 per unit
Manufacturer Lead Time Estimated Delivery 9 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £167.10
Trade pricing is personalised to your account

Manufacturer Lead Time

£167.10

Why Choose the ABB DS202CR M B20 A30 50/60 RCBO?

The ABB DS202CR M B20 A30 50/60 is a compact and highly reliable two-pole residual current circuit breaker with overcurrent protection (RCBO) designed to protect single-phase final circuits against overloads, short circuits and earth fault currents. As part of the ABB DS202CR series, it combines residual current and overcurrent protection within a space-saving two-module DIN-rail device.

This RCBO provides Type A residual current protection, detecting sinusoidal alternating and pulsating direct residual currents. Its B tripping characteristic provides sensitive magnetic overcurrent protection suitable for circuits with relatively low inrush currents, while the integrated residual current function provides additional protection against direct contact at a sensitivity of 30 mA.

With a rated current of 20 A, a rated residual operating current of 30 mA and a 10 kA short-circuit breaking capacity, the DS202CR M B20 A30 50/60 provides comprehensive circuit protection in a compact format. Its 230 V AC rated operational voltage and 50/60 Hz dual-frequency compatibility make this version particularly suitable for marine electrical installations and other demanding single-phase distribution applications.

Key Advantages

  • Combined residual current, overload and short-circuit protection in one compact device.
  • 20 A rated current with B-curve tripping characteristic.
  • 30 mA Type A residual current protection against sinusoidal AC and pulsating DC earth fault currents.
  • 10 kA rated short-circuit breaking capacity for robust circuit protection.
  • 50/60 Hz dual-frequency compatibility suitable for marine electrical systems.
  • Compact two-pole, two-module design saves valuable distribution board space.
  • Blue flag fault indication assists with identification of residual current trips.
  • DIN-rail mounting enables straightforward integration into electrical distribution equipment.

Key Features

  • ABB DS202CR M RCBO series.
  • 20 A rated current.
  • 30 mA rated residual operating current.
  • Type A residual current protection.
  • B tripping characteristic.
  • Two-pole configuration with both poles protected.
  • 230 V AC rated operational voltage.
  • 10 kA rated short-circuit breaking capacity.
  • 50/60 Hz operating frequency.
  • 4 kV rated impulse withstand voltage.
  • IP20 protection rating.
  • Blue flag fault indication for easier fault identification.
  • DIN-rail mounting with installation in any mounting position.

Reliable Combined Circuit and Residual Current Protection

RCBOs combine the functions of a miniature circuit breaker and residual current protection device within a single unit. The ABB DS202CR M B20 A30 50/60 therefore protects electrical circuits against excessive current caused by overloads and short circuits while simultaneously detecting residual earth leakage currents that could present a risk to people or electrical equipment.

The Type A residual current characteristic provides protection against sinusoidal alternating and pulsating direct earth fault currents. Together with its 30 mA sensitivity, B-curve overcurrent characteristic and 10 kA breaking capacity, the DS202CR provides dependable final-circuit protection while reducing the amount of space required within electrical distribution equipment.

Typical Applications

  • Marine electrical distribution systems.
  • Shipboard single-phase final circuits.
  • Lighting and auxiliary electrical circuits.
  • Socket and power distribution circuits.
  • Control and equipment circuits requiring 30 mA residual current protection.
  • Electrical panels requiring combined overcurrent and earth fault protection.

Technical Specifications

Series DS202CR
Product group DS200 / DSH200 RCBO
Order code 2CSR772198R1205
EAN 4022903034995
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 2
Number of protected poles 2
Rated current 20 A
Rated residual current 30 mA
Residual current type Type A
Tripping characteristic B
Rated operational voltage 230 V AC
Rated insulation voltage 440 V
Rated impulse withstand voltage 4 kV
Rated short-circuit breaking capacity 10 kA
Rated ultimate short-circuit breaking capacity (Icu) 10 kA
Rated service short-circuit breaking capacity (Ics) 7.5 kA
Frequency 50/60 Hz
Power loss 5.04 W
Energy limiting class 3
Electrical endurance 10,000 operations
Mechanical endurance 20,000 operations
Overvoltage category III
Protection rating IP20
Pollution degree 3
Operating temperature -25 to +55 °C
Storage temperature -40 to +70 °C
Tightening torque 4 N·m
Maximum cable size 35 mm²
Wire stripping length 11 mm
Mounting type DIN rail
Module width 2 modules
Standards IEC/EN 61009-1; IEC/EN 61009-2-1
Application Marine electrical installations
Weight approx. 0.245 kg

Frequently Asked Questions

What is the ABB DS202CR M B20 A30 50/60 used for?

This RCBO provides combined protection against overloads, short circuits and residual earth fault currents in single-phase final circuits, with the 50/60 Hz version particularly suited to marine electrical installations.

What is the rated current of the DS202CR M B20 A30 50/60?

The RCBO has a rated current of 20 A and uses a B tripping characteristic.

What residual current sensitivity does this RCBO provide?

The DS202CR M B20 A30 50/60 has a rated residual operating current of 30 mA and provides Type A residual current protection.

What is the breaking capacity of this ABB RCBO?

The DS202CR M B20 A30 50/60 has a rated short-circuit breaking capacity of 10 kA.

What does 50/60 mean in the ABB DS202CR M B20 A30 50/60 designation?

The 50/60 designation identifies the device's 50/60 Hz dual-frequency compatibility, making this version suitable for marine installations and electrical systems operating at either frequency.

Trusted ABB Circuit Protection

ABB DS202CR RCBOs combine residual current and overcurrent protection in a compact two-module DIN-rail format, providing dependable protection for single-phase circuits in demanding electrical installations.