Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB DS202CRMB65060HZ is a 2-pole Type A marine RCBO with a 6 A B-curve rating, 30 mA residual current sensitivity, 50/60 Hz dual-frequency compatibility and 10 kA breaking capacity.
£167.10
The ABB DS202CRMB65060HZ is a compact 2-pole residual current circuit breaker with overcurrent protection (RCBO) designed specifically for marine electrical applications requiring reliable operation at both 50 and 60 Hz. Part of the ABB DS202CR M 50/60 series, it combines protection against overloads, short circuits and residual earth fault currents within a space-saving two-module device.
This RCBO features Type A residual current detection for sinusoidal alternating and pulsating DC earth fault currents, together with a Type B tripping characteristic for overcurrent protection. Its 30 mA residual current sensitivity provides protection against indirect contact and additional protection against direct contact, while the dual-frequency design makes the device particularly suitable for shipboard and marine distribution systems.
With a rated current of 6 A, a rated residual operating current of 30 mA, 50/60 Hz dual-frequency compatibility and a rated short-circuit breaking capacity of 10 kA, the DS202CRMB65060HZ provides comprehensive circuit protection in a compact DIN-rail format. ABB order code 2CSR772198R1065 identifies the manufacturer type code DS202CR M B6 A30 50/60.
The ABB DS202CRMB65060HZ combines miniature circuit breaker and residual current protection functions in one compact device. It disconnects the protected circuit in response to overloads and short circuits while also detecting sinusoidal AC and pulsating DC earth fault currents, helping protect both electrical installations and people against electrical hazards.
The DS202CR M 50/60 range is specifically designed with dual-frequency compatibility for marine applications. Its compact two-module construction helps conserve valuable panel space, while the earth fault indicator, contact position indication and integrated test function support straightforward operation, fault identification and maintenance in shipboard electrical distribution systems.
| Series | DS202CR M 50/60 |
|---|---|
| Manufacturer type code | DS202CR M B6 A30 50/60 |
| ABB order code | 2CSR772198R1065 |
| Product type | Residual current circuit breaker with overcurrent protection (RCBO) |
| Application | Marine |
| Number of poles | 2 |
| Rated current | 6 A |
| Tripping characteristic | B |
| Residual current type | Type A |
| Rated residual operating current | 30 mA |
| Rated frequency | 50/60 Hz |
| Rated short-circuit breaking capacity (Icn) | 10 kA |
| Reference standards | IEC/EN 61009-1; IEC/EN 61009-2-1 |
| Mounting type | DIN rail |
| Module width | 2 modules |
| Weight | approx. 0.245 kg |
The DS202CRMB65060HZ is designed for marine electrical applications, providing combined protection against overloads, short circuits and residual earth fault currents in single-phase circuits.
The ABB DS202CRMB65060HZ has a rated current of 6 A and uses a Type B tripping characteristic.
The DS202CRMB65060HZ has a rated residual operating current of 30 mA and uses Type A residual current detection for sinusoidal AC and pulsating DC earth fault currents.
Yes. This DS202CR M variant is specifically designed for 50/60 Hz dual-frequency operation, making it suitable for marine electrical systems operating at either frequency.
The DS202CRMB65060HZ has a rated short-circuit breaking capacity of 10 kA.
ABB DS202CR M 50/60 RCBOs combine dual-frequency compatibility, residual current protection and overcurrent protection in a compact two-module format designed for dependable marine electrical distribution.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.