2CSR772140R3135 ABB DS202CRMB13A300 RCBO 2P Type A B13 300 mA 10 kA

2CSR772140R3135 ABB DS202CRMB13A300 RCBO 2P Type A B13 300 mA 10 kA

ABB DS202CRMB13A300 is a 2-pole Type A RCBO with a 13 A B-curve rating, 300 mA residual current sensitivity and 10 kA breaking capacity for combined overcurrent and earth fault protection.

SKU: 2CSR772140R3135Alt SKU: DS202CRMB13A300MPN: 2CSR772140R3135
Price
List Price £279.96 ex VAT
Your Price (ex VAT) Save 35%
£181.97 35% OFF
You save £97.99 per unit
Manufacturer Lead Time Estimated Delivery 9 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £181.97
Trade pricing is personalised to your account

Manufacturer Lead Time

£181.97

Why Choose the ABB DS202CRMB13A300 RCBO?

The ABB DS202CRMB13A300 is a compact and reliable 2-pole residual current circuit breaker with overcurrent protection (RCBO) designed to protect single-phase circuits against overloads, short circuits and residual earth fault currents. As part of the ABB DS202CR M series, it combines residual current and overcurrent protection within a space-saving two-module device for residential, commercial and industrial electrical distribution systems.

This Type A RCBO provides protection against sinusoidal alternating and pulsating DC residual currents, while its Type B tripping characteristic provides overcurrent protection suited to circuits with relatively low inrush currents. The integrated RCBO design simplifies distribution-board installation by combining functions that would otherwise require separate protective devices.

With a rated current of 13 A, a rated residual operating current of 300 mA and a 10 kA rated short-circuit breaking capacity, the DS202CRMB13A300 provides dependable circuit protection in a compact DIN-rail format. ABB order code 2CSR772140R3135 identifies this specific DS202CR M B13 Type A configuration.

Key Advantages

  • Combined overload, short-circuit and residual current protection in one device.
  • 13 A rated current for protected single-phase circuits.
  • Type B tripping characteristic for circuits with relatively low inrush currents.
  • 300 mA residual current sensitivity for earth leakage protection.
  • Type A residual current detection for sinusoidal AC and pulsating DC fault currents.
  • 10 kA rated short-circuit breaking capacity for robust fault protection.
  • Compact 2-pole, two-module construction saves distribution-board space.
  • DIN-rail mounting supports straightforward installation in modular distribution systems.

Key Features

  • ABB DS202CR M series RCBO.
  • 2-pole configuration in only two modules.
  • 13 A rated current.
  • 300 mA rated residual operating current.
  • Type A residual current characteristic.
  • Type B overcurrent tripping characteristic.
  • 10 kA rated short-circuit breaking capacity.
  • 230 V AC rated operating voltage.
  • 50 Hz rated frequency.
  • IP20 protection rating.
  • DIN-rail mounting for modular electrical distribution boards.

Reliable Combined Protection for Electrical Circuits

RCBOs such as the ABB DS202CRMB13A300 combine miniature circuit breaker and residual current protection functions in a single device. The RCBO disconnects the protected circuit in response to overload or short-circuit conditions while also detecting residual earth fault currents, helping provide comprehensive protection from a compact modular component.

The DS202CR series is designed for end-user single-phase circuits in residential, commercial and industrial installations. Its Type A residual current characteristic responds to sinusoidal alternating and pulsating DC earth fault currents, while the Type B overcurrent characteristic is suited to circuits where relatively low magnetic trip thresholds are required.

Typical Applications

  • Residential electrical distribution boards.
  • Commercial building electrical installations.
  • Industrial electrical distribution systems.
  • Single-phase branch circuits requiring combined protection.
  • Circuits requiring Type A residual current detection.
  • DIN-rail mounted modular distribution equipment.

Technical Specifications

Series DS202CR M
ABB order code 2CSR772140R3135
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 2
Rated current 13 A
Tripping characteristic B
Residual current type Type A
Rated residual operating current 300 mA
Rated operating voltage 230 V AC
Rated frequency 50 Hz
Rated short-circuit breaking capacity 10 kA
Rated service short-circuit breaking capacity 7.5 kA
Rated insulation voltage 440 V
Rated impulse withstand voltage 4 kV
Protection rating IP20
Pollution degree 3
Operating temperature -25 to +55 °C
Reference standards IEC/EN 61009-1; IEC/EN 61009-2-1
Mounting type DIN rail
Module width 2 modules
Dimensions (H × W × D) 86 × 36 × 72 mm
Weight approx. 0.22 kg

Frequently Asked Questions

What is the ABB DS202CRMB13A300 used for?

The DS202CRMB13A300 protects single-phase electrical circuits against overloads, short circuits and residual earth fault currents in residential, commercial and industrial installations.

What is the rated current of the DS202CRMB13A300?

The ABB DS202CRMB13A300 has a rated current of 13 A and a Type B tripping characteristic.

What residual current sensitivity does this RCBO provide?

The DS202CRMB13A300 has a rated residual operating current of 300 mA and uses Type A residual current detection.

What is the breaking capacity of the ABB DS202CRMB13A300?

The DS202CRMB13A300 has a rated short-circuit breaking capacity of 10 kA.

How is the ABB DS202CRMB13A300 installed?

The RCBO is designed for DIN-rail mounting and occupies two modules in a compatible modular distribution board or enclosure.

Trusted ABB Protection for Electrical Installations

ABB DS202CR RCBOs combine residual current and overcurrent protection in a compact two-module format, providing dependable protection for residential, commercial and industrial electrical distribution systems.