2CSR772140R3064 ABB DS202CRMC6A300 RCBO 2P Type A C6 300 mA 10 kA

2CSR772140R3064 ABB DS202CRMC6A300 RCBO 2P Type A C6 300 mA 10 kA

ABB DS202CRMC6A300 is a 2-pole Type A RCBO with a 6 A C-curve rating, 300 mA residual current sensitivity and 10 kA breaking capacity for combined overcurrent and earth leakage protection.

SKU: 2CSR772140R3064Alt SKU: DS202CRMC6A300MPN: 2CSR772140R3064
Price
List Price £279.96 ex VAT
Your Price (ex VAT) Save 35%
£181.97 35% OFF
You save £97.99 per unit
Manufacturer Lead Time Estimated Delivery 9 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £181.97
Trade pricing is personalised to your account

Manufacturer Lead Time

£181.97

Why Choose the ABB DS202CRMC6A300 RCBO?

The ABB DS202CRMC6A300 is a compact 2-pole residual current circuit breaker with overcurrent protection (RCBO) designed to provide combined protection against overloads, short circuits and earth leakage faults. Part of the ABB DS202CR M series, this device combines miniature circuit breaker and residual current protection functions in a space-saving two-module format.

This Type A RCBO detects sinusoidal alternating and pulsating DC residual currents, making it suitable for residential, commercial and industrial electrical installations. Its Type C tripping characteristic provides dependable overcurrent protection for circuits with moderate inrush currents, while the integrated test pushbutton enables routine verification of the residual current protection function.

With a rated current of 6 A, rated residual operating current of 300 mA and rated short-circuit breaking capacity of 10 kA, the DS202CRMC6A300 provides robust circuit protection in a compact DIN-rail device. ABB order code 2CSR772140R3064 identifies this specific DS202CR M Type A, C-curve configuration.

Key Advantages

  • Combined overload, short-circuit and residual current protection in one device.
  • 6 A rated current with Type C tripping characteristic.
  • 300 mA residual current sensitivity for earth leakage protection.
  • Type A residual current detection for sinusoidal AC and pulsating DC fault currents.
  • 10 kA breaking capacity for robust short-circuit protection.
  • Compact 2-pole, two-module design helps conserve distribution-board space.
  • Integrated test pushbutton for checking correct residual current operation.
  • Earth fault and contact position indication assists fault identification and maintenance.

Key Features

  • ABB DS202CR M series RCBO.
  • 2-pole configuration with both poles protected.
  • 6 A rated current.
  • 300 mA rated residual operating current.
  • Type A residual current characteristic.
  • Type C overcurrent tripping characteristic.
  • 10 kA rated short-circuit breaking capacity.
  • 50 Hz rated frequency.
  • DIN-rail mounting for modular distribution equipment.
  • Test pushbutton, earth fault indicator and contact position indicator.

Reliable Combined Circuit and Earth Leakage Protection

An RCBO combines the functions of a miniature circuit breaker and a residual current device within a single protective component. The ABB DS202CRMC6A300 disconnects the protected circuit when excessive current caused by an overload or short circuit is detected, while also responding to residual earth leakage currents.

The DS202CR series is engineered for compact distribution systems where comprehensive protection and efficient use of panel space are important. Type A residual current detection provides protection against both sinusoidal alternating and pulsating DC earth fault currents, while the integrated earth fault indicator and contact position indicator help simplify troubleshooting and maintenance.

Typical Applications

  • Residential electrical distribution boards.
  • Commercial building electrical installations.
  • Industrial distribution and control panels.
  • Branch circuits requiring combined overcurrent and earth leakage protection.
  • Equipment and machinery auxiliary circuits.
  • DIN-rail mounted modular electrical distribution systems.

Technical Specifications

Series DS202CR M
ABB order code 2CSR772140R3064
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 2
Rated current 6 A
Tripping characteristic C
Residual current type Type A
Rated residual operating current 300 mA
Rated short-circuit breaking capacity (Icn) 10 kA
Rated frequency 50 Hz
Protection rating IP20
Reference standards IEC/EN 61009-1; IEC/EN 61009-2-1
Mounting DIN rail
Module width 2 modules
Dimensions (W × H × D) 36 × 86 × 72 mm
Weight approx. 0.245 kg

Frequently Asked Questions

What is the ABB DS202CRMC6A300 used for?

The DS202CRMC6A300 provides combined protection against overloads, short circuits and residual earth leakage currents in residential, commercial and industrial electrical circuits.

What is the rated current of the DS202CRMC6A300?

The ABB DS202CRMC6A300 has a rated current of 6 A and uses a Type C tripping characteristic.

What residual current sensitivity does this RCBO provide?

This model has a rated residual operating current of 300 mA and is a Type A RCBO for detecting sinusoidal AC and pulsating DC residual currents.

What is the breaking capacity of the ABB DS202CRMC6A300?

The DS202CRMC6A300 has a rated short-circuit breaking capacity of 10 kA.