2CSR772140R1104 ABB DS202CRMC10A30 DS202CR M C10 A30 2P 10A 30mA Type A RCBO

2CSR772140R1104 ABB DS202CRMC10A30 DS202CR M C10 A30 2P 10A 30mA Type A RCBO

ABB DS202CRMC10A30 is a 2-pole 10 A C-curve Type A RCBO with 30 mA residual current sensitivity, 230 V AC rating and 10 kA short-circuit breaking capacity for combined overcurrent and earth fault protection.

SKU: 2CSR772140R1104Alt SKU: DS202CRMC10A30MPN: 2CSR772140R1104
Price
List Price £257.08 ex VAT
Your Price (ex VAT) Save 35%
£167.10 35% OFF
You save £89.98 per unit
Manufacturer Lead Time Estimated Delivery 9 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £167.10
Trade pricing is personalised to your account

Manufacturer Lead Time

£167.10

Why Choose the ABB DS202CRMC10A30 RCBO?

The ABB DS202CRMC10A30 is a compact 2-pole residual current circuit breaker with overcurrent protection (RCBO) designed to protect end-user single-phase circuits against overloads, short circuits and residual earth fault currents. Part of the ABB DS202CR M series within the DS200 / DSH200 RCBO product group, it combines residual current and overcurrent protection in a space-saving two-module device.

This RCBO provides Type A residual current protection, detecting sinusoidal AC and pulsating DC residual currents. Its C tripping characteristic is suitable for circuits with moderate inrush currents, while the 30 mA rated residual operating current provides protection against indirect contact and additional protection against direct contact.

With a rated current of 10 A, a rated voltage of 230 V AC and a 10 kA rated short-circuit breaking capacity, the DS202CRMC10A30 provides robust combined protection in a compact DIN rail format. Its two protected poles and high breaking capacity make it suitable for residential, commercial and industrial electrical installations.

Key Advantages

  • Combined residual current and overcurrent protection in one compact RCBO.
  • 10 A rated current with C tripping characteristic.
  • 30 mA Type A residual current protection.
  • Detects sinusoidal AC and pulsating DC residual currents.
  • 10 kA rated short-circuit breaking capacity for robust fault protection.
  • 2 protected poles in only two modules for efficient use of distribution board space.

Key Features

  • ABB DS202CR M RCBO series.
  • 2-pole configuration with 2 protected poles.
  • 10 A rated current.
  • C tripping characteristic.
  • Type A residual current protection.
  • 30 mA rated residual operating current.
  • 230 V AC rated voltage.
  • 50 Hz rated frequency.
  • 10 kA rated short-circuit breaking capacity (Icn).
  • 7.5 kA rated service short-circuit breaking capacity (Ics).
  • 440 V rated insulation voltage (Ui).
  • 4 kV rated impulse withstand voltage (Uimp).
  • IP20 protection rating.
  • DIN rail mounting in a compact two-module format.

Reliable Combined Circuit and Residual Current Protection

RCBOs combine the functions of a miniature circuit breaker and residual current device in a single protective device. The ABB DS202CRMC10A30 protects end-user single-phase circuits against overload and short-circuit currents while also disconnecting the supply when potentially hazardous residual earth fault currents are detected.

The Type A characteristic provides protection against sinusoidal alternating and pulsating direct residual currents. With its 30 mA residual current sensitivity, C tripping characteristic and 10 kA short-circuit breaking capacity, the DS202CRMC10A30 provides dependable combined protection for circuits that may experience moderate starting or inrush currents.

Typical Applications

  • Residential electrical installations.
  • Commercial electrical distribution systems.
  • Industrial electrical installations.
  • End-user single-phase circuits.
  • Lighting and general-purpose circuits.
  • Circuits supplying electrical and electronic equipment.
  • Circuits with moderate starting or inrush currents.
  • Distribution boards requiring combined overcurrent and 30 mA residual current protection.

Technical Specifications

Series DS202CR M
Product group DS200 / DSH200 RCBO
ABB order code 2CSR772140R1104
EAN 4022903034407
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 2
Number of protected poles 2
Rated current 10 A
Tripping characteristic C
Residual current type Type A
Rated residual current 30 mA
Rated voltage 230 V AC
Rated frequency 50 Hz
Rated short-circuit breaking capacity (Icn) 10 kA
Rated service short-circuit breaking capacity (Ics) 7.5 kA
Rated insulation voltage (Ui) 440 V
Rated impulse withstand voltage (Uimp) 4 kV
Protection rating IP20
Standards IEC/EN 61009-1; IEC/EN 61009-2-1
Mounting type DIN rail
Module width 2 modules
Dimensions (W × H × D) 36 × 86 × 72 mm
Weight approx. 0.245 kg

Frequently Asked Questions

What is the ABB DS202CRMC10A30 used for?

The ABB DS202CRMC10A30 is an RCBO designed to protect end-user single-phase circuits against overloads, short circuits and residual earth fault currents in residential, commercial and industrial installations.

What is the current rating of the ABB DS202CRMC10A30?

The DS202CRMC10A30 has a rated current of 10 A and uses a C tripping characteristic.

What residual current protection does this RCBO provide?

The DS202CRMC10A30 provides Type A residual current protection with a rated residual operating current of 30 mA, detecting sinusoidal AC and pulsating DC residual currents.

What is the breaking capacity of the ABB DS202CRMC10A30?

The DS202CRMC10A30 has a rated short-circuit breaking capacity (Icn) of 10 kA and a rated service short-circuit breaking capacity (Ics) of 7.5 kA.

What does the C characteristic mean on the DS202CRMC10A30?

The C tripping characteristic is suitable for circuits that can experience moderate inrush currents, making the RCBO appropriate for a wide range of residential, commercial and industrial electrical loads.

Trusted ABB Circuit Protection

ABB DS202CR M RCBOs combine residual current and overcurrent protection in a compact two-module format, providing dependable protection for end-user single-phase circuits across residential, commercial and industrial electrical installations.