2CSR772140R0164 ABB DS202CRMC16A10 16 A 2-Pole Type A 10 mA RCBO

2CSR772140R0164 ABB DS202CRMC16A10 16 A 2-Pole Type A 10 mA RCBO

ABB DS202CRMC16A10 is a 16 A 2-pole Type A RCBO with C tripping characteristic and 10 mA residual-current sensitivity for combined overload, short-circuit and earth-fault protection.

SKU: 2CSR772140R0164Alt SKU: DS202CRMC16A10MPN: 2CSR772140R0164
Price
List Price £273.12 ex VAT
Your Price (ex VAT) Save 35%
£177.53 35% OFF
You save £95.59 per unit
Manufacturer Lead Time Estimated Delivery 9 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £177.53
Trade pricing is personalised to your account

Manufacturer Lead Time

£177.53

Why Choose the ABB DS202CRMC16A10 RCBO?

The ABB DS202CRMC16A10 is a 2-pole residual current circuit breaker with overcurrent protection (RCBO) designed to combine overload, short-circuit and residual-current protection within a single modular protective device. Part of the ABB DS200 / DSH200 RCBO range, the DS202CR M C16 A10 provides coordinated circuit and earth-fault protection for professional electrical distribution applications.

With a rated current of 16 A, C tripping characteristic and highly sensitive 10 mA rated residual operating current, this RCBO is intended for circuits where a lower residual-current operating threshold is required. Its Type A residual-current characteristic provides detection of sinusoidal AC residual currents and pulsating DC residual currents.

The 2-pole configuration provides switching of both circuit conductors, while the C characteristic is suitable for circuits with moderate starting or inrush currents. Combining these characteristics in one DIN-rail device makes the DS202CRMC16A10 a practical choice for dedicated circuits requiring 16 A overcurrent protection together with sensitive 10 mA Type A residual-current protection.

Key Advantages

  • Combined residual-current, overload and short-circuit protection in one modular device.
  • 16 A rated current for dedicated electrical circuits.
  • C tripping characteristic suitable for loads with moderate starting or inrush currents.
  • Highly sensitive 10 mA rated residual operating current.
  • Type A residual-current detection for sinusoidal AC and pulsating DC residual currents.
  • 2-pole configuration for switching both circuit conductors.
  • Modular construction for integration into DIN-rail electrical distribution systems.

Key Features

  • ABB DS202CR M RCBO.
  • 2-pole configuration.
  • 16 A rated current.
  • C tripping characteristic.
  • 10 mA rated residual operating current.
  • Type A residual-current characteristic.
  • Combined overload, short-circuit and residual-current protection.
  • Detection of sinusoidal AC and pulsating DC residual currents.
  • Modular design for DIN-rail electrical distribution systems.

Sensitive Combined Circuit and Residual-Current Protection

An RCBO combines overcurrent and residual-current protection in one device, allowing the ABB DS202CRMC16A10 to respond to overloads and short circuits while also detecting leakage currents to earth. Its 10 mA residual-current sensitivity provides a lower operating threshold than commonly used 30 mA RCBO variants, making it suitable for circuits where particularly sensitive residual-current detection is specified.

The Type A characteristic enables the DS202CRMC16A10 to detect sinusoidal alternating residual currents and pulsating DC residual currents. This capability is relevant to modern circuits containing electronic components that can generate residual-current waveforms beyond those covered by conventional AC-only residual-current protection.

Typical Applications

  • Dedicated circuits requiring sensitive 10 mA residual-current protection.
  • Commercial and professional electrical distribution systems.
  • Electrical control and automation panels.
  • Circuits supplying loads with moderate starting or inrush currents.
  • Circuits supplying electronic equipment capable of producing pulsating DC residual currents.
  • Applications requiring combined 16 A overcurrent and Type A residual-current protection.

Technical Specifications

Series DS200 / DSH200 RCBO
Order code 2CSR772140R0164
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 2
Rated current 16 A
Tripping characteristic C
Residual-current type Type A
Rated residual current 10 mA
Mounting type DIN rail

Frequently Asked Questions

What is the ABB DS202CRMC16A10 used for?

The DS202CRMC16A10 is a 2-pole RCBO used to protect electrical circuits against overloads, short circuits and residual earth fault currents.

What is the current rating of the DS202CRMC16A10?

The ABB DS202CRMC16A10 has a rated current of 16 A and uses a C tripping characteristic.

What residual-current sensitivity does the DS202CRMC16A10 provide?

The DS202CRMC16A10 has a rated residual operating current of 10 mA, providing sensitive residual-current detection for circuits where this operating threshold is specified.

What does Type A mean on the ABB DS202CRMC16A10?

Type A means the RCBO is designed to detect sinusoidal AC residual currents as well as pulsating DC residual currents, making it suitable for many circuits containing modern electronic equipment.

How many poles does the DS202CRMC16A10 have?

The DS202CRMC16A10 is a 2-pole RCBO, providing switching of both circuit conductors.

Trusted ABB Circuit Protection

ABB DS200 and DSH200 RCBOs combine overcurrent and residual-current protection in a compact modular format, providing dependable protection for modern electrical distribution and control installations.