2CSR752140R3105 ABB DS202CRB10A300 10 A 2-Pole Type A 300 mA RCBO

2CSR752140R3105 ABB DS202CRB10A300 10 A 2-Pole Type A 300 mA RCBO

ABB DS202CRB10A300 is a 10 A 2-pole Type A RCBO with B tripping characteristic and 300 mA residual-current sensitivity for combined overload, short-circuit and earth-fault protection.

SKU: 2CSR752140R3105Alt SKU: DS202CRB10A300MPN: 2CSR752140R3105
Price
List Price £262.26 ex VAT
Your Price (ex VAT) Save 35%
£170.47 35% OFF
You save £91.79 per unit
Manufacturer Lead Time Estimated Delivery 9 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £170.47
Trade pricing is personalised to your account

Manufacturer Lead Time

£170.47

Why Choose the ABB DS202CRB10A300 RCBO?

The ABB DS202CRB10A300 is a compact 2-pole residual current circuit breaker with overcurrent protection (RCBO) designed to provide combined protection against overloads, short circuits and residual earth fault currents. Part of the ABB DS200 / DSH200 RCBO range, it integrates overcurrent and residual-current protection within a single modular protective device.

With a rated current of 10 A, B tripping characteristic and 300 mA rated residual operating current, the DS202CR B10 A300 provides coordinated protection for electrical circuits and connected equipment. Its Type A residual-current characteristic detects sinusoidal AC residual currents and pulsating DC residual currents, making it suitable for circuits containing many types of modern electronic equipment.

The 2-pole configuration provides switching of both circuit conductors, while the B characteristic is suitable for circuits with relatively low starting or inrush currents. The 300 mA residual-current rating makes this version suitable where earth-fault and leakage-current protection at that sensitivity is specified.

Key Advantages

  • Combined residual-current, overload and short-circuit protection in one modular device.
  • 10 A rated current for lower-current electrical circuits.
  • B tripping characteristic suitable for loads with relatively low starting or inrush currents.
  • 300 mA rated residual operating current for earth-fault and leakage-current protection.
  • Type A residual-current detection for sinusoidal AC and pulsating DC residual currents.
  • 2-pole configuration for switching both circuit conductors.
  • Compact modular format for integration into DIN-rail electrical distribution systems.

Key Features

  • ABB DS202CR RCBO.
  • 2-pole configuration.
  • 10 A rated current.
  • B tripping characteristic.
  • 300 mA rated residual operating current.
  • Type A residual-current characteristic.
  • Combined overload, short-circuit and residual-current protection.
  • Detection of sinusoidal AC and pulsating DC residual currents.
  • Modular design for DIN-rail electrical distribution systems.

Reliable Combined Circuit and Residual-Current Protection

An RCBO combines the functions of a miniature circuit breaker and a residual-current protective device within a single unit. The ABB DS202CRB10A300 therefore protects the connected circuit against overload and short-circuit currents while also detecting residual currents caused by insulation faults, leakage to earth or other electrical faults.

Its Type A characteristic enables detection of both sinusoidal alternating residual currents and pulsating DC residual currents. Combined with a 300 mA residual-current threshold, this makes the DS202CRB10A300 suitable for installations where Type A earth-fault protection at this sensitivity is specified rather than the 30 mA sensitivity commonly selected for additional protection against electric shock.

Typical Applications

  • Electrical circuits requiring 300 mA Type A residual-current protection.
  • Commercial and industrial electrical distribution boards.
  • Electrical control and automation panels.
  • Lighting, heating and other loads with relatively low inrush currents.
  • Circuits containing electronic equipment capable of producing pulsating DC residual currents.
  • Applications requiring combined overcurrent and earth-fault protection in a single modular device.

Technical Specifications

Series DS200 / DSH200 RCBO
Order code 2CSR752140R3105
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 2
Rated current 10 A
Tripping characteristic B
Residual-current type Type A
Rated residual current 300 mA
Mounting type DIN rail

Frequently Asked Questions

What is the ABB DS202CRB10A300 used for?

The DS202CRB10A300 is an RCBO designed to protect electrical circuits against overloads, short circuits and residual earth fault currents, with a rated residual operating current of 300 mA.

What is the current rating of the DS202CRB10A300?

The ABB DS202CRB10A300 has a rated current of 10 A and uses a B tripping characteristic.

What residual-current sensitivity does the DS202CRB10A300 provide?

The DS202CRB10A300 has a rated residual operating current of 300 mA.

What does Type A mean on the ABB DS202CRB10A300?

Type A means the RCBO is designed to detect sinusoidal AC residual currents as well as pulsating DC residual currents, supporting protection of circuits containing many types of modern electronic equipment.

How many poles does the DS202CRB10A300 have?

The DS202CRB10A300 is a 2-pole RCBO, providing switching of both circuit conductors.

Trusted ABB Circuit Protection

ABB DS200 and DSH200 RCBOs combine overcurrent and residual-current protection in a compact modular format, providing dependable protection for modern electrical distribution and control installations.