2CSR752140R1405 ABB DS202CRB40A30 40 A 2-Pole Type A 30 mA RCBO

2CSR752140R1405 ABB DS202CRB40A30 40 A 2-Pole Type A 30 mA RCBO

ABB DS202CRB40A30 is a 40 A 2-pole Type A RCBO with B tripping characteristic and 30 mA residual-current sensitivity for combined overload, short-circuit and earth-fault protection.

SKU: 2CSR752140R1405Alt SKU: DS202CRB40A30MPN: 2CSR752140R1405
Price
List Price £248.92 ex VAT
Your Price (ex VAT) Save 35%
£161.80 35% OFF
You save £87.12 per unit
Manufacturer Lead Time Estimated Delivery 9 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £161.80
Trade pricing is personalised to your account

Manufacturer Lead Time

£161.80

Why Choose the ABB DS202CRB40A30 RCBO?

The ABB DS202CRB40A30 is a compact and dependable 2-pole residual current circuit breaker with overcurrent protection (RCBO) designed to provide combined protection against overloads, short circuits and residual earth fault currents. Part of the ABB DS200 / DSH200 RCBO range, it combines overcurrent and residual-current protection in a single modular device for electrical distribution circuits.

With a rated current of 40 A, B tripping characteristic and 30 mA rated residual operating current, the DS202CR B40 A30 provides coordinated protection for final circuits and connected equipment. Its Type A residual-current characteristic detects sinusoidal AC residual currents as well as pulsating DC residual currents, making it suitable for modern electrical installations containing electronic loads.

The 2-pole configuration provides switching of both circuit conductors, while the B characteristic is suitable for circuits with relatively low inrush currents. Its 30 mA sensitivity supports additional protection against electric shock, making the DS202CRB40A30 a practical protective device for commercial, industrial and other professional electrical distribution applications.

Key Advantages

  • Combined residual-current, overload and short-circuit protection in one modular device.
  • 40 A rated current for higher-current electrical circuits.
  • B tripping characteristic suitable for circuits with relatively low starting or inrush currents.
  • 30 mA residual-current sensitivity for additional protection against electric shock.
  • Type A residual-current detection for sinusoidal AC and pulsating DC fault currents.
  • 2-pole configuration for switching both circuit conductors.
  • Compact modular format for straightforward integration into DIN-rail distribution systems.

Key Features

  • ABB DS202CR RCBO.
  • 2-pole configuration.
  • 40 A rated current.
  • B tripping characteristic.
  • 30 mA rated residual operating current.
  • Type A residual-current characteristic.
  • Combined overload, short-circuit and residual-current protection.
  • Detection of sinusoidal AC and pulsating DC residual currents.
  • Modular design for DIN-rail electrical distribution systems.

Reliable Combined Circuit and Residual-Current Protection

An RCBO combines the functions of a miniature circuit breaker and a residual-current protective device within a single unit. The ABB DS202CRB40A30 therefore protects connected circuits against overload and short-circuit currents while also detecting leakage to earth caused by insulation faults or other electrical problems.

The Type A characteristic enables the RCBO to respond to sinusoidal alternating residual currents and pulsating DC residual currents. This makes Type A protection particularly relevant to modern installations where electronic power supplies, controls and other semiconductor-based equipment can produce residual-current waveforms requiring more than conventional AC-only detection.

Typical Applications

  • Electrical final circuits requiring 30 mA residual-current protection.
  • Commercial and industrial distribution boards.
  • Electrical control and automation panels.
  • Lighting, heating and other loads with relatively low inrush currents.
  • Circuits supplying modern electronic equipment.
  • Applications requiring combined overcurrent and Type A residual-current protection.

Technical Specifications

Series DS200 / DSH200 RCBO
Order code 2CSR752140R1405
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 2
Rated current 40 A
Tripping characteristic B
Residual-current type Type A
Rated residual current 30 mA
Mounting type DIN rail

Frequently Asked Questions

What is the ABB DS202CRB40A30 used for?

The DS202CRB40A30 is an RCBO used to protect electrical circuits against overloads, short circuits and residual earth fault currents.

What is the current rating of the DS202CRB40A30?

The ABB DS202CRB40A30 has a rated current of 40 A and uses a B tripping characteristic.

What residual-current sensitivity does this RCBO provide?

The DS202CRB40A30 has a rated residual operating current of 30 mA.

What does Type A mean on the ABB DS202CRB40A30?

Type A means the RCBO is designed to detect sinusoidal AC residual currents and pulsating DC residual currents, making it suitable for many circuits containing modern electronic equipment.

How many poles does the DS202CRB40A30 have?

The DS202CRB40A30 is a 2-pole RCBO, providing switching of both circuit conductors.

Trusted ABB Circuit Protection

ABB DS200 and DSH200 RCBOs combine overcurrent and residual-current protection in a compact modular format, providing dependable circuit protection for modern electrical distribution installations.