ABB DS201 M B25 F30 is a 1P+N Type F RCBO with a 25 A rated current, 30 mA residual current sensitivity, B tripping characteristic and 10 kA rated short-circuit breaking capacity for dependable protection of single-phase circuits including lines supplying inverters and electronically controlled equipment.
£581.72
The ABB DS201 M B25 F30 is a 1P+N Type F residual current circuit breaker with overcurrent protection (RCBO) designed to protect single-phase circuits against overloads, short circuits and residual earth fault currents. As part of the established ABB DS200 / DSH200 RCBO product group, it combines residual current and overcurrent protection within a compact DIN-rail device for residential, commercial and industrial electrical installations.
Its Type F residual current characteristic provides protection against sinusoidal AC, pulsating DC and high-frequency residual currents up to 1 kHz, making it specifically suitable for circuits supplying single-phase inverters. The B tripping characteristic is suited to compatible circuits with relatively low starting and inrush currents, while Type F technology also provides increased resistance to unwanted tripping caused by transient disturbances.
With a rated current of 25 A, a rated residual operating current of 30 mA and a rated short-circuit breaking capacity of 10 kA, the DS201 M B25 F30 provides dependable combined circuit protection. Its 1P+N configuration, compact DIN-rail format and Type F residual current detection make it a practical solution for modern single-phase installations incorporating inverter-based and electronically controlled equipment.
RCBOs such as the ABB DS201 M combine miniature circuit-breaker and residual current protection functions within a single device. The DS201 M B25 F30 can disconnect the protected circuit in response to overload, short-circuit or qualifying residual earth fault currents, while its 30 mA residual current sensitivity provides protection against indirect contact and additional protection against direct contact.
The Type F characteristic provides protection against sinusoidal AC, pulsating DC and high-frequency residual currents up to 1 kHz and offers increased resistance to unwanted tripping. Combined with its B curve overcurrent characteristic, the DS201 M B25 F30 is particularly suitable for compatible circuits supplying single-phase inverters and other electronically controlled loads with relatively low starting and inrush currents.
| Series | DS201 M Type F |
|---|---|
| Product group | DS200 / DSH200 RCBO |
| ABB type code | DS201MB25F30 |
| ABB order code | 2CSR275580R1255 |
| Product type | Residual current circuit breaker with overcurrent protection (RCBO) |
| Number of poles | 1P+N |
| Rated current | 25 A |
| Rated frequency | 50–60 Hz |
| Rated residual current | 30 mA |
| Residual current type | Type F |
| Tripping characteristic | B |
| Residual current frequency capability | Up to 1 kHz |
| Rated short-circuit breaking capacity (Icn) | 10 kA |
| Ultimate short-circuit breaking capacity (Icu) | 15 kA |
| Resistance to unwanted tripping (8/20 waveform) | 3 kA |
| Dimensions (W × H × D) | 35 × 85 × 69 mm |
| Weight | approx. 0.24 kg |
| Degree of protection | IP20 / IP40 |
| Mounting type | DIN rail |
| Standards | IEC/EN 61009-1, IEC/EN 61009-2-1, IEC/EN 62423 |
The ABB DS201 M B25 F30 protects compatible single-phase circuits against overload, short-circuit and residual earth fault currents and is specifically suitable for circuits supplying single-phase inverters and electronically controlled equipment.
The RCBO has a rated current of 25 A with a B tripping characteristic, making it suitable for compatible circuits with relatively low starting and inrush currents.
The DS201 M B25 F30 has a rated residual operating current of 30 mA and uses a Type F residual current characteristic.
Type F provides protection against sinusoidal AC, pulsating DC and high-frequency residual currents up to 1 kHz, while also providing increased resistance to unwanted tripping. It is specifically suitable for circuits supplying single-phase inverters.
The DS201 M B25 F30 has a rated short-circuit breaking capacity (Icn) of 10 kA and an ultimate short-circuit breaking capacity (Icu) of 15 kA.
ABB DS201 M Type F RCBOs combine residual current and overcurrent protection in a compact DIN-rail format, providing dependable circuit protection for residential, commercial and industrial installations including applications supplying single-phase inverters and electronically controlled equipment.