Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB DS201 M C25 F30 is a 1P+N Type F RCBO with a 25 A rated current, 30 mA residual current sensitivity, C tripping characteristic and 10 kA rated short-circuit breaking capacity, specifically suited to protecting single-phase circuits supplying inverters and electronically controlled equipment.
£543.68
The ABB DS201 M C25 F30 is a compact 1P+N Type F residual current circuit breaker with overcurrent protection (RCBO) designed to protect single-phase final circuits against overloads, short circuits and residual earth fault currents. As part of the established ABB DS200 / DSH200 RCBO product group, it combines residual current and overcurrent protection within a two-module DIN-rail device for residential, commercial and industrial electrical installations.
Its Type F residual current characteristic incorporates APR features for increased resistance to unwanted tripping and can detect high-frequency residual currents up to 1 kHz. This makes the DS201 M C25 F30 particularly suitable for circuits supplying single-phase inverters and electronically controlled equipment, while the C tripping characteristic accommodates moderate starting and inrush currents.
With a rated current of 25 A, a rated residual operating current of 30 mA and a rated short-circuit breaking capacity of 10 kA, the DS201 M C25 F30 provides dependable combined protection for compatible single-phase circuits. Its 230 V rated voltage, 1P+N configuration and compact DIN-rail format provide a practical protection solution for modern electrical installations containing inverter-based and electronically controlled loads.
RCBOs such as the ABB DS201 M combine miniature circuit-breaker and residual current protection functions within a single device. The DS201 M C25 F30 can disconnect the protected circuit in response to overload, short-circuit or qualifying residual earth fault currents, while its 30 mA residual current sensitivity provides protection against indirect contact and additional protection against direct contact.
The Type F characteristic incorporates APR features for increased resistance to unwanted tripping and extends residual current detection to high-frequency currents up to 1 kHz. Combined with its C curve overcurrent characteristic, the DS201 M C25 F30 is particularly suitable for compatible circuits supplying single-phase inverters and other electronically controlled loads with moderate starting or inrush currents.
| Series | DS201 M Type F |
|---|---|
| Product group | DS200 / DSH200 RCBO |
| ABB type code | DS201MC25F30 |
| ABB order code | 2CSR275580R1254 |
| GTIN / EAN | 8012542593119 |
| Product type | Residual current circuit breaker with overcurrent protection (RCBO) |
| Number of poles | 1P+N |
| Rated current | 25 A |
| Rated voltage | 230 V |
| Rated operational voltage | 240 V AC |
| Rated frequency | 50–60 Hz |
| Rated residual current | 30 mA |
| Residual current type | Type F |
| Tripping characteristic | C |
| Residual current frequency capability | Up to 1 kHz |
| Rated short-circuit breaking capacity (Icn) | 10 kA |
| Ultimate short-circuit breaking capacity (Icu) | 15 kA |
| Rated insulation voltage (Ui) | 500 V |
| Dimensions (W × H × D) | 35 × 85 × 69 mm |
| Weight | approx. 0.2 kg |
| Degree of protection | IP20 / IP40 |
| Mounting type | DIN rail |
| Standards | IEC/EN 61009-1, IEC/EN 61009-2-1, IEC/EN 62423 |
The ABB DS201 M C25 F30 protects single-phase final circuits against overload, short-circuit and residual earth fault currents and is specifically suitable for circuits supplying single-phase inverters and electronically controlled equipment.
The RCBO has a rated current of 25 A with a C tripping characteristic, making it suitable for compatible circuits with moderate starting and inrush currents.
The DS201 M C25 F30 has a rated residual operating current of 30 mA and uses a Type F residual current characteristic.
Type F incorporates APR features for increased resistance to unwanted tripping and can detect high-frequency residual currents up to 1 kHz, making it particularly suitable for circuits supplying single-phase inverters.
The DS201 M C25 F30 has a rated short-circuit breaking capacity (Icn) of 10 kA and an ultimate short-circuit breaking capacity (Icu) of 15 kA.
ABB DS201 M Type F RCBOs combine residual current and overcurrent protection in a compact DIN-rail format, providing dependable circuit protection for residential, commercial and industrial installations including applications supplying single-phase inverters and electronically controlled equipment.
We use cookies