Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB DS201MC16F30 is a 16 A 1P+N Type F RCBO with C tripping characteristic, 30 mA residual-current sensitivity and 10 kA short-circuit breaking capacity for combined overcurrent and earth-fault protection.
£543.68
The ABB DS201MC16F30 is a compact and reliable 1P+N residual current circuit breaker with overcurrent protection (RCBO) designed to provide combined protection against overloads, short circuits and residual earth fault currents. Part of the ABB DS201 M / System pro M compact range, it combines residual-current and overcurrent protection in a single modular device for single-phase electrical circuits.
With a rated current of 16 A, C tripping characteristic and 30 mA rated residual operating current, the DS201 M C16 F30 provides coordinated protection for final circuits. Its Type F residual-current characteristic is designed to detect sinusoidal AC and pulsating DC residual currents while also providing protection for circuits containing single-phase frequency converters and other loads capable of producing composite residual currents.
The DS201MC16F30 combines a 10 kA rated short-circuit breaking capacity with 230–240 V AC operation and standard DIN-rail mounting. Its Type F characteristic also provides increased resistance to unwanted tripping from transient disturbances, making the RCBO particularly useful for modern electrical installations containing electronically controlled equipment.
An RCBO combines miniature circuit-breaker and residual-current protection functions within one device. The ABB DS201MC16F30 therefore disconnects the protected circuit in response to overloads and short circuits while also detecting potentially hazardous residual currents caused by insulation faults or leakage to earth.
Type F residual-current protection is particularly relevant to modern equipment using variable-speed or frequency-controlled electronics. In addition to the residual-current waveforms covered by Type A devices, Type F RCBOs are designed for appropriate single-phase frequency-converter applications and provide increased immunity to unwanted tripping, supporting both electrical safety and continuity of service.
| Series | DS201 M / System pro M compact |
|---|---|
| Order code | 2CSR275580R1164 |
| Product type | Residual current circuit breaker with overcurrent protection (RCBO) |
| Configuration | 1P+N |
| Number of protected poles | 1 |
| Rated current | 16 A |
| Tripping characteristic | C |
| Residual-current type | Type F |
| Rated residual current | 30 mA |
| Rated operational voltage | 230–240 V AC |
| Rated frequency | 50 / 60 Hz |
| Rated short-circuit breaking capacity | 10 kA |
| Mounting type | 35 mm DIN rail |
| Width | 35 mm |
| Standards | IEC/EN 61009-1 |
The DS201MC16F30 is an RCBO designed to protect single-phase circuits against overloads, short circuits and residual earth fault currents, including applications with suitable frequency-controlled electronic loads.
The ABB DS201MC16F30 has a rated current of 16 A and uses a C tripping characteristic.
The DS201MC16F30 has a rated residual operating current of 30 mA.
Type F residual-current protection is intended for circuits with modern electronic loads, including suitable single-phase frequency converters, and can detect composite residual-current waveforms in addition to those covered by Type A protection.
The DS201MC16F30 has a rated short-circuit breaking capacity of 10 kA.
ABB DS201 M Type F RCBOs combine overcurrent and advanced residual-current protection in a compact modular format, providing dependable protection for modern electrical installations and electronically controlled loads.