2CSR275189R1165 ABB DS201 M B16 A30 110V RCBO 1P+N 16 A 30 mA Type A

2CSR275189R1165 ABB DS201 M B16 A30 110V RCBO 1P+N 16 A 30 mA Type A

ABB DS201 M B16 A30 110V is a 1P+N Type A RCBO with a 16 A rated current, 30 mA residual current sensitivity, B tripping characteristic and 110 V AC configuration for combined overcurrent and residual current protection.

SKU: 2CSR275189R1165Alt SKU: DS201MB16A30110VMPN: 2CSR275189R1165
Price
List Price £201.73 ex VAT
Your Price (ex VAT) Save 35%
£131.12 35% OFF
You save £70.61 per unit
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £131.12
Trade pricing is personalised to your account

Manufacturer Lead Time

£131.12

Why Choose the ABB DS201 M B16 A30 110V RCBO?

The ABB DS201 M B16 A30 110V is a compact and reliable 1P+N Type A residual current circuit breaker with overcurrent protection (RCBO) designed to protect compatible single-phase circuits against overloads, short circuits and residual earth leakage faults. As part of the established ABB DS200 / DSH200 RCBO product group, it combines residual current and overcurrent protection within a single DIN-rail device for electrical distribution and control applications.

This RCBO provides Type A residual current protection, enabling detection of sinusoidal AC residual currents and pulsating DC residual currents. Its B tripping characteristic is suited to circuits with relatively low starting and inrush currents, while the integrated RCBO design provides both overcurrent and residual current protection within one compact protective device.

With a rated current of 16 A, a rated residual operating current of 30 mA and a 110 V AC voltage configuration, the DS201 M B16 A30 110V is designed for compatible low-voltage single-phase applications. Its 1P+N configuration provides protection of the phase conductor together with neutral switching, making it suitable for distribution boards and control systems requiring dedicated 110 V circuit protection.

Key Advantages

  • Combined residual current and overcurrent protection in one RCBO.
  • 16 A rated current for compatible single-phase electrical circuits.
  • 30 mA rated residual operating current for sensitive earth leakage protection.
  • 110 V AC configuration for compatible low-voltage systems.
  • Type A residual current detection for sinusoidal AC and pulsating DC residual currents.
  • B tripping characteristic suitable for circuits with relatively low starting and inrush currents.
  • 1P+N configuration combining phase protection with neutral switching.
  • Compact DIN-rail format for efficient electrical distribution and control-panel installation.

Key Features

  • ABB DS201 M RCBO series.
  • 16 A rated current.
  • 30 mA rated residual operating current.
  • 110 V AC voltage configuration.
  • Type A residual current characteristic.
  • B curve overcurrent tripping characteristic.
  • 1P+N pole configuration.
  • Protection against overload and short-circuit currents.
  • Protection against sinusoidal AC and pulsating DC residual currents.
  • DIN-rail mounting for electrical distribution equipment.

Reliable Combined Circuit and Residual Current Protection

RCBOs such as the ABB DS201 M combine the functions of a miniature circuit breaker and residual current device within a single protective unit. The DS201 M B16 A30 110V can disconnect the protected circuit in response to overload, short-circuit or qualifying residual earth leakage currents, providing coordinated protection while reducing the need for separate protective devices.

The Type A residual current characteristic enables the DS201 M B16 A30 110V to respond to sinusoidal alternating residual currents as well as pulsating DC residual currents. Combined with its B curve overcurrent characteristic and 30 mA residual current sensitivity, this makes the RCBO suitable for compatible 110 V circuits requiring combined overcurrent and residual current protection.

Typical Applications

  • 110 V electrical distribution circuits.
  • Industrial control panels and control systems.
  • Low-voltage single-phase electrical circuits.
  • Control and auxiliary circuits.
  • Compatible lighting and equipment circuits.
  • Circuits with relatively low starting and inrush currents.
  • Distribution circuits requiring combined overcurrent and residual current protection.

Technical Specifications

Series DS201 M
Product group DS200 / DSH200 RCBO
ABB order code 2CSR275189R1165
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 1P+N
Rated current 16 A
Voltage configuration 110 V AC
Rated residual current 30 mA
Residual current type Type A
Tripping characteristic B
Mounting type DIN rail

Frequently Asked Questions

What is the ABB DS201 M B16 A30 110V used for?

The ABB DS201 M B16 A30 110V is an RCBO designed to protect compatible 110 V single-phase circuits against overload, short-circuit and residual earth leakage currents.

What is the rated current of the DS201 M B16 A30 110V?

The RCBO has a rated current of 16 A with a B tripping characteristic.

What residual current rating does this RCBO have?

The DS201 M B16 A30 110V has a rated residual operating current of 30 mA and uses Type A residual current detection.

What voltage is the ABB DS201 M B16 A30 110V designed for?

This DS201 M variant is configured for 110 V AC applications, making it suitable for compatible low-voltage electrical distribution and control circuits.

What does the B characteristic mean on the DS201 M B16 A30 110V?

The B tripping characteristic is suited to circuits with relatively low starting and inrush currents while providing dependable overload and short-circuit protection.

Trusted ABB Circuit Protection

ABB DS201 M RCBOs combine residual current and overcurrent protection in a compact DIN-rail format, providing dependable protection for electrical distribution, control and auxiliary circuits.