2CSR275189R1065 ABB DS201 M B6 A30 110V RCBO 1P+N 6 A 30 mA Type A

2CSR275189R1065 ABB DS201 M B6 A30 110V RCBO 1P+N 6 A 30 mA Type A

ABB DS201 M B6 A30 110V is a 1P+N Type A RCBO with a 6 A rated current, 30 mA residual current sensitivity, B tripping characteristic and 110 V AC configuration for combined overcurrent and residual current protection.

SKU: 2CSR275189R1065Alt SKU: DS201MB6A30110VMPN: 2CSR275189R1065
Price
List Price £201.73 ex VAT
Your Price (ex VAT) Save 35%
£131.12 35% OFF
You save £70.61 per unit
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £131.12
Trade pricing is personalised to your account

Manufacturer Lead Time

£131.12

Why Choose the ABB DS201 M B6 A30 110V RCBO?

The ABB DS201 M B6 A30 110V is a compact and reliable 1P+N Type A residual current circuit breaker with overcurrent protection (RCBO) designed to protect compatible single-phase circuits against overloads, short circuits and residual earth leakage faults. As part of the established ABB DS200 / DSH200 RCBO product group, it combines residual current and overcurrent protection within a single DIN-rail device for electrical distribution and control applications.

This RCBO provides Type A residual current protection, enabling detection of sinusoidal AC residual currents and pulsating DC residual currents. Its B tripping characteristic is suited to circuits with relatively low starting and inrush currents, while the integrated RCBO design provides overcurrent and residual current protection within one compact protective device.

With a rated current of 6 A, a rated residual operating current of 30 mA and a 110 V AC voltage configuration, the DS201 M B6 A30 110V is designed for compatible low-voltage single-phase applications. Its 1P+N configuration provides protection of the phase conductor together with neutral switching, making it suitable for distribution boards and control systems requiring dedicated 110 V circuit protection.

Key Advantages

  • Combined residual current and overcurrent protection in one RCBO.
  • 6 A rated current for low-current electrical circuits.
  • 30 mA rated residual operating current for sensitive earth leakage protection.
  • 110 V AC configuration for compatible low-voltage systems.
  • Type A residual current detection for sinusoidal AC and pulsating DC residual currents.
  • B tripping characteristic suitable for circuits with relatively low starting and inrush currents.
  • 1P+N configuration combining phase protection with neutral switching.
  • Compact DIN-rail format for efficient electrical distribution and control-panel installation.

Key Features

  • ABB DS201 M RCBO series.
  • 6 A rated current.
  • 30 mA rated residual operating current.
  • 110 V AC voltage configuration.
  • Type A residual current characteristic.
  • B curve overcurrent tripping characteristic.
  • 1P+N pole configuration.
  • Protection against overload and short-circuit currents.
  • Protection against sinusoidal AC and pulsating DC residual currents.
  • DIN-rail mounting for electrical distribution equipment.

Reliable Combined Circuit and Residual Current Protection

RCBOs such as the ABB DS201 M combine the functions of a miniature circuit breaker and residual current device within a single protective unit. The DS201 M B6 A30 110V can disconnect the protected circuit in response to overload, short-circuit or qualifying residual earth leakage currents, providing coordinated protection while reducing the need for separate protective devices.

The Type A residual current characteristic enables the DS201 M B6 A30 110V to respond to sinusoidal alternating residual currents as well as pulsating DC residual currents. Combined with its B curve overcurrent characteristic and 30 mA residual current sensitivity, this makes the RCBO suitable for compatible 110 V circuits requiring combined overcurrent and residual current protection.

Typical Applications

  • 110 V electrical distribution circuits.
  • Industrial control panels and control systems.
  • Low-current single-phase electrical circuits.
  • Control and auxiliary circuits.
  • Compatible lighting and equipment circuits.
  • Circuits with relatively low starting and inrush currents.
  • Distribution circuits requiring combined overcurrent and residual current protection.

Technical Specifications

Series DS201 M
Product group DS200 / DSH200 RCBO
ABB order code 2CSR275189R1065
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 1P+N
Rated current 6 A
Voltage configuration 110 V AC
Rated residual current 30 mA
Residual current type Type A
Tripping characteristic B
Mounting type DIN rail

Frequently Asked Questions

What is the ABB DS201 M B6 A30 110V used for?

The ABB DS201 M B6 A30 110V is an RCBO designed to protect compatible 110 V single-phase circuits against overload, short-circuit and residual earth leakage currents.

What is the rated current of the DS201 M B6 A30 110V?

The RCBO has a rated current of 6 A with a B tripping characteristic.

What residual current rating does this RCBO have?

The DS201 M B6 A30 110V has a rated residual operating current of 30 mA and uses Type A residual current detection.

What voltage is the ABB DS201 M B6 A30 110V designed for?

This DS201 M variant is configured for 110 V AC applications, making it suitable for compatible low-voltage electrical distribution and control circuits.

What does the B characteristic mean on the DS201 M B6 A30 110V?

The B tripping characteristic is suited to circuits with relatively low starting and inrush currents while providing dependable overload and short-circuit protection.

Trusted ABB Circuit Protection

ABB DS201 M RCBOs combine residual current and overcurrent protection in a compact DIN-rail format, providing dependable protection for electrical distribution, control and auxiliary circuits.