2CSR274001R1065 ABB DS204MACB60.03 DS204 M AC-B6/0.03 6 A 30 mA 10 kA 4P Type AC RCBO

2CSR274001R1065 ABB DS204MACB60.03 DS204 M AC-B6/0.03 6 A 30 mA 10 kA 4P Type AC RCBO

ABB DS204MACB60.03 (2CSR274001R1065) is a four-pole 6 A Type AC RCBO with B tripping characteristic, 30 mA residual-current sensitivity and 10 kA short-circuit breaking capacity.

SKU: 2CSR274001R1065Alt SKU: DS204MACB60.03MPN: 2CSR274001R1065
Price
List Price £382.17 ex VAT
Your Price (ex VAT) Save 35%
£248.41 35% OFF
You save £133.76 per unit
Manufacturer Lead Time Estimated Delivery 9 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £248.41
Trade pricing is personalised to your account

Manufacturer Lead Time

£248.41

Why Choose the ABB DS204MACB60.03 RCBO?

The ABB DS204MACB60.03, manufacturer order code 2CSR274001R1065, is a compact and reliable four-pole residual current circuit breaker with overcurrent protection (RCBO) designed to provide combined protection against overloads, short circuits and sinusoidal AC residual currents. As part of the established ABB DS200 / DS204 M RCBO series, it combines residual-current and overcurrent protection within a single modular protective device.

The DS204 M AC-B6/0.03 provides a 6 A rated current, B tripping characteristic and 30 mA rated residual operating current. Its Type AC residual-current characteristic is designed to detect sinusoidal alternating residual currents, while the integrated overcurrent protection safeguards the circuit against overload and short-circuit conditions.

With a 10 kA short-circuit breaking capacity and four poles, the DS204MACB60.03 is suitable for three-phase electrical distribution applications requiring multi-pole circuit protection. Its modular construction enables straightforward installation within electrical distribution boards and control panels.

Key Advantages

  • Combined residual-current and overcurrent protection in a single RCBO.
  • 6 A rated current for suitable low-current circuits.
  • 30 mA residual operating current for additional protection against electric shock.
  • 10 kA short-circuit breaking capacity for robust circuit protection.
  • Type AC residual-current detection for sinusoidal alternating residual currents.
  • B-curve tripping characteristic suitable for circuits with relatively low inrush currents.
  • Four-pole configuration for three-phase electrical distribution systems.

Key Features

  • ABB DS200 / DS204 M RCBO series.
  • 6 A rated current.
  • 30 mA rated residual current.
  • 10 kA short-circuit breaking capacity.
  • Type AC residual-current characteristic.
  • Type B overcurrent tripping characteristic.
  • Four-pole configuration.
  • Combined protection against overload, short-circuit and residual earth fault currents.
  • Modular design for electrical distribution boards and control panels.

Combined Circuit and Residual-Current Protection

RCBOs combine the functions of overcurrent and residual-current protection in one device. The ABB DS204 M AC-B6/0.03 protects connected circuits against excessive current caused by overloads and short circuits while also detecting sinusoidal AC residual currents that can arise from insulation faults and earth leakage.

The 30 mA residual-current sensitivity provides additional protection against electric shock, while the Type AC characteristic responds to sinusoidal alternating residual currents. Combined with its 10 kA short-circuit breaking capacity and B-curve overcurrent characteristic, the DS204MACB60.03 provides comprehensive protection for suitable four-pole electrical circuits.

Typical Applications

  • Three-phase electrical distribution systems.
  • Commercial electrical installations.
  • Industrial distribution boards and control panels.
  • Circuits requiring combined overload and earth-leakage protection.
  • Circuits with resistive or relatively low-inrush loads suited to a B tripping characteristic.
  • Applications requiring four-pole circuit protection.
  • Final distribution circuits requiring 30 mA residual-current protection.

Technical Specifications

Series DS200 / DS204 M
Manufacturer material ID DS204MACB60.03
Manufacturer order code 2CSR274001R1065
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 4
Rated current 6 A
Rated residual current 30 mA
Residual-current type AC
Tripping characteristic B
Short-circuit breaking capacity 10 kA
Mounting type DIN-rail mounting

Frequently Asked Questions

What is the ABB DS204MACB60.03 used for?

The ABB DS204MACB60.03 is an RCBO used to protect suitable four-pole electrical circuits against overloads, short circuits and sinusoidal AC residual earth fault currents.

What is the rated current of the ABB DS204 M AC-B6/0.03?

The device has a rated current of 6 A with a B tripping characteristic.

What residual-current sensitivity does this RCBO provide?

The DS204 M AC-B6/0.03 has a rated residual operating current of 30 mA and uses Type AC residual-current detection for sinusoidal alternating residual currents.

What is the breaking capacity of the DS204MACB60.03?

The ABB DS204MACB60.03 has a 10 kA short-circuit breaking capacity.

How many poles does the ABB DS204 M AC-B6/0.03 have?

The DS204 M AC-B6/0.03 is a four-pole RCBO designed for suitable multi-pole and three-phase electrical distribution applications.

Trusted ABB Circuit Protection

ABB DS200 series RCBOs combine residual-current and overcurrent protection in modular protective devices, helping provide dependable protection against overloads, short circuits, residual earth fault currents and electric-shock hazards in electrical distribution systems.