2CSR273001R1505 ABB DS203MACB500.03 DS203 M AC-B50/0.03 50 A 30 mA 10 kA 3P RCBO

2CSR273001R1505 ABB DS203MACB500.03 DS203 M AC-B50/0.03 50 A 30 mA 10 kA 3P RCBO

ABB DS203MACB500.03 (2CSR273001R1505) is a three-pole 50 A Type AC RCBO with B tripping characteristic, 30 mA residual-current sensitivity and 10 kA short-circuit breaking capacity.

SKU: 2CSR273001R1505Alt SKU: DS203MACB500.03MPN: 2CSR273001R1505
Price
List Price £398.03 ex VAT
Your Price (ex VAT) Save 35%
£258.72 35% OFF
You save £139.31 per unit
Manufacturer Lead Time Estimated Delivery 9 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £258.72
Trade pricing is personalised to your account

Manufacturer Lead Time

£258.72

Why Choose the ABB DS203MACB500.03 RCBO?

The ABB DS203MACB500.03, manufacturer order code 2CSR273001R1505, is a high-performance three-pole residual current circuit breaker with overcurrent protection (RCBO) designed to provide combined protection against overloads, short circuits and sinusoidal AC earth leakage currents. Part of the established ABB DS200 / DS203 M RCBO series, it combines overcurrent and residual-current protection within a single modular protective device.

The DS203 M AC-B50/0.03 provides a 50 A rated current, B tripping characteristic and 30 mA rated residual operating current. Its Type AC residual-current detection is intended for sinusoidal alternating earth fault currents, while the integrated overcurrent element protects circuits against overload and short-circuit conditions.

With a 10 kA short-circuit breaking capacity and three protected poles, the DS203MACB500.03 is suitable for demanding three-phase electrical distribution applications where dependable circuit and earth-leakage protection are required. Its modular construction is designed for installation within electrical distribution boards and control panels.

Key Advantages

  • Combined residual-current and overcurrent protection in a single RCBO.
  • 50 A rated current for higher-current three-phase circuits.
  • 30 mA residual operating current for additional protection against electric shock.
  • 10 kA short-circuit breaking capacity for robust circuit protection.
  • Type AC residual-current detection for sinusoidal alternating earth fault currents.
  • B-curve tripping characteristic for appropriate circuit overcurrent protection.
  • Three protected poles for use with three-phase electrical circuits.

Key Features

  • ABB DS200 / DS203 M RCBO series.
  • 50 A rated current.
  • 30 mA rated residual current.
  • 10 kA breaking capacity.
  • Type AC residual-current characteristic.
  • Type B overcurrent tripping characteristic.
  • Three protected poles.
  • Combined protection against overload, short-circuit and earth fault currents.
  • Modular format for electrical distribution and protection systems.

Combined Circuit and Residual-Current Protection

RCBOs combine the functions of overcurrent and residual-current protection in one device. The ABB DS203 M AC-B50/0.03 protects connected circuits against excessive current caused by overloads and short circuits while also detecting sinusoidal alternating earth leakage currents that can create electric-shock and electrical safety hazards.

The 30 mA residual-current sensitivity provides additional protection against direct contact, while residual-current operation also supports protection against indirect contact. Combined with its 10 kA breaking capacity and B-curve overcurrent characteristic, the device provides comprehensive protection for suitable three-phase circuits in commercial and industrial electrical installations.

Typical Applications

  • Three-phase electrical distribution circuits.
  • Commercial electrical installations.
  • Industrial distribution boards and control panels.
  • Circuits requiring combined overload and earth-leakage protection.
  • Electrical equipment with predominantly resistive or low-inrush loads.
  • Final distribution circuits requiring 30 mA residual-current protection.

Technical Specifications

Series DS200 / DS203 M
Manufacturer order code 2CSR273001R1505
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of protected poles 3
Rated current 50 A
Rated residual current 30 mA
Residual-current type AC
Tripping characteristic B
Short-circuit breaking capacity 10 kA
Product width approx. 122 mm
Product height approx. 93 mm
Product depth approx. 69 mm
Product net weight approx. 0.65 kg
EAN 8012542934004

Frequently Asked Questions

What is the ABB DS203MACB500.03 used for?

The ABB DS203MACB500.03 is an RCBO used to protect three-phase electrical circuits against overloads, short circuits and sinusoidal AC earth leakage currents.

What is the rated current of the ABB DS203 M AC-B50/0.03?

The device has a rated current of 50 A with a B tripping characteristic.

What residual-current sensitivity does this RCBO provide?

The DS203 M AC-B50/0.03 has a rated residual operating current of 30 mA and uses Type AC residual-current detection for sinusoidal alternating earth fault currents.

What is the breaking capacity of the DS203MACB500.03?

The ABB DS203MACB500.03 has a 10 kA short-circuit breaking capacity.

How many poles does the ABB DS203 M AC-B50/0.03 have?

This RCBO has three protected poles and is designed for suitable three-phase electrical circuits.

Trusted ABB Circuit Protection

ABB DS200 series RCBOs combine residual-current and overcurrent protection in compact modular devices, helping provide dependable protection against overloads, short circuits, earth fault currents and electric-shock hazards in electrical distribution systems.