2CSR273001R1504 ABB DS203 M AC-C50/0.03 RCBO 3P 50 A 30 mA 10 kA

2CSR273001R1504 ABB DS203 M AC-C50/0.03 RCBO 3P 50 A 30 mA 10 kA

ABB DS203 M AC-C50/0.03 is a 50 A 3-pole Type AC 30 mA RCBO with C-curve overcurrent protection, 10 kA short-circuit breaking capacity and additional terminals for remote tripping for commercial and industrial three-phase electrical circuits.

SKU: 2CSR273001R1504Alt SKU: DS203MACC500.03MPN: 2CSR273001R1504
Price
List Price £410.24 ex VAT
Your Price (ex VAT) Save 35%
£266.66 35% OFF
You save £143.58 per unit
Manufacturer Lead Time Estimated Delivery 9 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £266.66
Trade pricing is personalised to your account

Manufacturer Lead Time

£266.66

Why Choose the ABB DS203 M AC-C50/0.03 RCBO?

The ABB DS203 M AC-C50/0.03, order code 2CSR273001R1504, is a high-performance 3-pole residual current circuit breaker with overcurrent protection (RCBO) designed to protect three-phase electrical circuits against overloads, short circuits and sinusoidal alternating earth fault currents. Part of the ABB DS200 / DSH200 RCBO product group, it combines residual-current and overcurrent protection in a factory-assembled device for commercial and industrial electrical installations.

This DS200 M series RCBO uses Type AC residual-current protection together with a C tripping characteristic. It provides protection against indirect contact and, with its 30 mA rated residual operating current, additional protection against direct contact. The C-curve characteristic is suited to circuits with moderate starting or inrush currents, making it appropriate for a broad range of commercial and industrial loads.

With a rated current of 50 A, 30 mA residual-current sensitivity and 10 kA short-circuit breaking capacity, the DS203 M AC-C50/0.03 provides robust combined protection for higher-current three-pole circuits. This 50 A version is also provided with additional terminals for remote tripping, extending its suitability for professional distribution and control applications.

Key Advantages

  • Combined residual current, overload and short-circuit protection in one device.
  • 50 A rated current with C-curve overcurrent tripping characteristic.
  • 30 mA residual current sensitivity provides additional protection against direct contact.
  • Type AC protection for sinusoidal alternating residual currents.
  • 3-pole configuration for three-phase electrical circuits.
  • 10 kA short-circuit breaking capacity for demanding commercial and industrial applications.
  • Additional terminals for remote tripping on this 50 A version.
  • DIN rail mounting enables straightforward integration into modular electrical distribution systems.

Key Features

  • ABB DS200 M RCBO series.
  • 50 A rated current.
  • C tripping characteristic.
  • 30 mA rated residual current (IΔn).
  • Type AC residual-current protection.
  • 3-pole configuration.
  • 10 kA short-circuit breaking capacity.
  • Additional terminals for remote tripping.
  • Protection against overload and short-circuit currents.
  • Protection against sinusoidal alternating earth fault currents.
  • Protection against indirect contact and additional protection against direct contact.
  • C-curve operation suited to circuits with moderate starting or inrush currents.
  • Factory-assembled combined residual-current and overcurrent protection.
  • Designed for commercial and industrial three-phase electrical applications.

Reliable 10 kA Three-Phase Circuit Protection

An RCBO combines residual-current protection with overload and short-circuit protection within a single device. The ABB DS203 M AC-C50/0.03 protects three-pole circuits against excessive current while also detecting sinusoidal alternating earth leakage currents, providing coordinated protection for commercial and industrial three-phase electrical distribution systems.

The DS203 M AC-C50/0.03 combines its 50 A C-curve overcurrent characteristic with 30 mA Type AC residual-current protection and a 10 kA short-circuit breaking capacity. Its additional remote-tripping terminals further enhance integration into professional distribution and control systems where remote tripping functionality is required.

Typical Applications

  • Commercial three-phase electrical distribution systems.
  • Industrial distribution boards and control panels.
  • Circuits requiring combined 50 A overcurrent and 30 mA residual-current protection.
  • Three-phase resistive and inductive loads suited to a C-curve characteristic.
  • Three-pole circuits requiring Type AC residual-current protection.
  • Higher-current circuits requiring a 10 kA short-circuit breaking capacity.
  • Applications where additional terminals for remote tripping are beneficial.

Technical Specifications

Product group DS200 / DSH200 RCBO
Series DS200 M
ABB order code 2CSR273001R1504
EAN 8012542853305
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 3
Rated current 50 A
Tripping characteristic C curve
Rated residual current (IΔn) 30 mA
Residual current type Type AC
Short-circuit breaking capacity 10 kA
Additional provision Additional terminals for remote tripping
Application Commercial and industrial electrical installations
Mounting DIN rail
Weight approx. 0.65 kg

Frequently Asked Questions

What is the ABB DS203 M AC-C50/0.03 used for?

The ABB DS203 M AC-C50/0.03 is a 3-pole RCBO used to protect three-phase electrical circuits against overloads, short circuits and sinusoidal alternating earth fault currents in commercial and industrial installations.

What is the current rating of the DS203 M AC-C50/0.03?

The RCBO has a rated current of 50 A and uses a C-curve tripping characteristic, making it suitable for circuits with moderate starting or inrush currents.

What residual current sensitivity does this RCBO have?

The DS203 M AC-C50/0.03 has a rated residual operating current of 30 mA and uses Type AC residual-current protection.

What is the breaking capacity of the ABB DS203 M AC-C50/0.03?

The DS203 M AC-C50/0.03 has a 10 kA short-circuit breaking capacity, providing robust short-circuit protection for suitable commercial and industrial three-phase installations.

Does the ABB DS203 M AC-C50/0.03 support remote tripping?

Yes. This 50 A version of the DS203 M is provided with additional terminals for remote tripping, allowing it to be integrated into applications requiring remote trip functionality.

Trusted ABB Circuit Protection

ABB DS200 M RCBOs combine residual-current and overcurrent protection in factory-assembled devices designed for reliable commercial and industrial electrical distribution, with the DS203 M range providing robust three-pole protection for demanding three-phase applications.