2CSR273001R1325 ABB DS203MACB320.03 DS203 M AC-B32/0.03 32 A 30 mA RCBO

2CSR273001R1325 ABB DS203MACB320.03 DS203 M AC-B32/0.03 32 A 30 mA RCBO

ABB DS203MACB320.03 is a 3-pole 32 A Type B AC-type RCBO with 30 mA residual-current sensitivity and 10 kA nominal short-circuit breaking capacity for three-phase commercial and industrial circuit protection.

SKU: 2CSR273001R1325Alt SKU: DS203MACB320.03MPN: 2CSR273001R1325
Price
List Price £331.78 ex VAT
Your Price (ex VAT) Save 35%
£215.66 35% OFF
You save £116.12 per unit
Manufacturer Lead Time Estimated Delivery 9 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £215.66
Trade pricing is personalised to your account

Manufacturer Lead Time

£215.66

Why Choose the ABB DS203MACB320.03 RCBO?

The ABB DS203MACB320.03 is a high-performance 3-pole residual current circuit breaker with overcurrent protection (RCBO) designed to provide combined protection against overloads, short circuits and sinusoidal AC earth fault currents. Part of the established ABB DS200 / DS203 M series, it integrates residual-current and overcurrent protection into a single DIN-rail mounted device for commercial and industrial three-phase electrical installations.

With a rated current of 32 A, 30 mA residual-current sensitivity and Type B tripping characteristic, the DS203 M AC-B32/0.03 provides dependable protection for circuits requiring sensitive overcurrent operation. Its AC-type residual-current detection responds to sinusoidal alternating earth fault currents, while the 30 mA sensitivity provides additional protection against electric shock.

The DS203MACB320.03 provides a nominal short-circuit breaking capacity of 10 kA and is designed for three-phase electrical distribution applications. ABB supplies this model under order code 2CSR273001R1325, combining robust circuit protection with a modular format suitable for professional distribution boards and control panels.

Key Advantages

  • Combined residual-current, overload and short-circuit protection in one device.
  • 3-pole configuration for three-phase circuit protection.
  • 32 A rated current for commercial and industrial circuits.
  • 30 mA residual-current sensitivity for additional protection against electric shock.
  • Type B tripping characteristic for responsive overcurrent protection.
  • AC-type residual-current detection for sinusoidal alternating earth fault currents.
  • 10 kA nominal short-circuit breaking capacity for demanding electrical installations.
  • Integrated test facility enables routine verification of residual-current operation.

Key Features

  • ABB DS203 M AC RCBO from the DS200 series.
  • 3-pole configuration.
  • 32 A rated current.
  • 30 mA rated residual operating current.
  • B characteristic overcurrent release.
  • AC-type residual-current protection.
  • 10 kA nominal short-circuit breaking capacity.
  • Combined overload, short-circuit and residual-current protection.
  • Detection of sinusoidal alternating residual currents.
  • DIN-rail format for modular electrical distribution equipment.
  • Integrated test pushbutton for checking residual-current functionality.

Reliable Three-Phase Circuit and Residual-Current Protection

RCBOs combine overcurrent and residual-current protection within a single protective device. The ABB DS203 M AC-B32/0.03 protects three-phase circuits against overload and short-circuit currents while also detecting sinusoidal alternating earth leakage currents that can present a risk to people, wiring and connected equipment.

The ABB DS200 range is designed for professional electrical distribution applications where dependable protection and efficient panel installation are required. Combining circuit-breaker and residual-current functions within one device reduces the need for separate protective components, while the integrated test facility supports routine functional checks during inspection and maintenance.

Typical Applications

  • Commercial three-phase electrical distribution boards.
  • Industrial electrical installations.
  • Three-phase final circuits.
  • Industrial control and automation circuits.
  • Lighting and general power distribution.
  • Electrical control and distribution panels.
  • Circuits requiring combined 30 mA AC-type residual-current and overcurrent protection.

Technical Specifications

Series DS200 / DS203 M
SKU DS203MACB320.03
ABB order code 2CSR273001R1325
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 3
Rated current 32 A
Tripping characteristic B
Residual-current type AC
Rated residual current 30 mA
Nominal short-circuit breaking capacity 10 kA
Rated voltage 400 V AC
Mounting DIN rail

Frequently Asked Questions

What is the ABB DS203MACB320.03 used for?

The ABB DS203MACB320.03 provides combined protection against overloads, short circuits and sinusoidal AC residual currents in three-phase commercial and industrial electrical installations.

What is the rated current of the DS203 M AC-B32/0.03?

The RCBO has a rated current of 32 A and uses a Type B tripping characteristic.

What residual-current sensitivity does this RCBO provide?

The DS203 M AC-B32/0.03 has a rated residual operating current of 30 mA and provides AC-type detection for sinusoidal alternating residual currents.

What is the short-circuit capacity of the ABB DS203MACB320.03?

The DS203MACB320.03 has a nominal short-circuit breaking capacity of 10 kA.

What is the ABB order code for the DS203 M AC-B32/0.03?

The ABB order code is 2CSR273001R1325.

Trusted ABB Circuit Protection

ABB DS200 series RCBOs provide integrated residual-current and overcurrent protection for commercial and industrial electrical systems, combining dependable circuit protection with practical modular installation and straightforward functional testing.